• 제목/요약/키워드: Static Measurement

검색결과 710건 처리시간 0.024초

자유단 공진시험을 이용한 암석의 탄성계수 측정 (Measurements of Elastic Moduli of Rock Cores Using Free-Free Resonance Tests)

  • 목영진
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.353-360
    • /
    • 1998
  • Dynamic measurements are used rather sparingly to determine the elastic moduli of rock cores and modulus values are not much utilized in design practice. The reason seems to result from the general perception that values obtained by dynamic measurement are much higher (about 10 times) than those determined statically. This paper presents results from dynamic and static tests on rock cores. The findings are : 1) elastic moduli can be consistently determined by laboratory seismic testing. 2) nonlear deformation characteristic of rock cores was tentatively proposed with variation in elastic modulus with strain.

  • PDF

상대변위를 이용한 지반정수 인식 (Identification of Geotechnical Paramters Using Relative Convergence Measurements)

  • 최상현;조국환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.418-423
    • /
    • 2005
  • In designing underground structure such as tunnels, estimating geotechnical characteristics of the ground is one of the most important and difficult tasks. In this paper, a methodology that can identify geotechnical parameters using only field-measured relative convergence displacements is presented. By using only relative convergence measurement data, inevitable errors in absolute convergence estimation can be avoided and in turn the parameter estimation process can be simplified. The methodology utilizes sensitivity relationship between static displacement measurements and geotechnical parameters. The feasibility and applicability of the proposed methodology is verified via a 3-d numerical example of a tunnel structure.

  • PDF

위상 및 방향 변조를 위한 초소형 광 변조기의 설계와 제작 (Design and Fabrication of Micro SLM for Phase and Amplitude Modulation)

  • 장석환;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3298-3300
    • /
    • 1999
  • In this paper, a $10{\times}10$ micro SLM array for phase and amplitude modulation of incident light is designed and fabricated using surface micromachining technology. Hidden spring structure is used in order to maximize the fill-factor and minimize diffraction effect at the support posts. Static and dynamic characteristics of designed micro SLM are simulated with ABAQUS and measured with optical measurement system using He-Ne laser and PSD(position sensitive devise).

  • PDF

A New Method for Extracting Interface Trap Density in Short-Channel MOSFETs from Substrate-Bias-Dependent Subthreshold Slopes

  • Lyu, Jong-Son
    • ETRI Journal
    • /
    • 제15권2호
    • /
    • pp.11-25
    • /
    • 1993
  • Interface trap densities at gate oxide/silicon substrate ($SiO_2/Si$) interfaces of metal oxide semiconductor field-effect transistors (MOSFETs) were determined from the substrate bias dependence of the subthreshold slope measurement. This method enables the characterization of interface traps residing in the energy level between the midgap and that corresponding to the strong inversion of small size MOSFET. In consequence of the high accuracy of this method, the energy dependence of the interface trap density can be accurately determined. The application of this technique to a MOSFET showed good agreement with the result obtained through the high-frequency/quasi-static capacitance-voltage (C-V) technique for a MOS capacitor. Furthermore, the effective substrate dopant concentration obtained through this technique also showed good agreement with the result obtained through the body effect measurement.

  • PDF

경작지(耕作地)에서 메탄 및 아산화질소(亞酸化窒素) 배출량(排出量) 측정방법(測定方法) (Methods for Measurement of Methane and Nitrous Oxide Emissions from Agricultural Fields)

  • 신용광;김광식
    • 한국환경농학회지
    • /
    • 제13권3호
    • /
    • pp.359-372
    • /
    • 1994
  • A simplified closed static chamber method was devised for measurement of methane flux from paddy fields. Compared to automatic methane measuring system(AMMS) this chamber method provides availability with moderate costs of setup and maintenance, while it also provides the time-effectiveness compared to other closed top-type chamber method. It accomodates 30 chambers within 2 hours sampling period with two persons. And it provide a rapid and accurate analysis of methane, 30-40 samples per hour. Modified method for $N_2O$ measurements provides a precise and accurate analysis of nitrous oxide without upgrading additional heating zones for gas sampling(switching) valves.

  • PDF

GPS Output Signal Processing considering both Correlated/White Measurement Noise for Optimal Navigation Filtering

  • Kim, Do-Myung;Suk, Jinyoung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권4호
    • /
    • pp.499-506
    • /
    • 2012
  • In this paper, a dynamic modeling for the velocity and position information of a single frequency stand-alone GPS(Global Positioning System) receiver is described. In static condition, the position error dynamic model is identified as a first/second order transfer function, and the velocity error model is identified as a band-limited Gaussian white noise via non-parametric method of a PSD(Power Spectrum Density) estimation in continuous time domain. A Kalman filter is proposed considering both correlated/white measurements noise based on identified GPS error model. The performance of the proposed Kalman filtering method is verified via numerical simulation.

저가형 Ll 1주파 GPS 수신기를 이용한 계측 모니터링 시스템 개발 (Development of a Structural Measurement System Using Low-Cost L1 Single Frequency GPS Receivers)

  • 박기정;이상현;최준성
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.47-52
    • /
    • 2006
  • In recent years, there is a strong urge to introduce GPS systems which can role in reference points and measure global positions to the field of structural measurements. In this study, a new structural measurement system using low-cost L1 single frequency GPS receivers instead of conventional expensive RTK L1&L2 dual frequency GPS receiver. This system consists of GPS OEM board, GPS antenna, wireless access points, and monitoring program based on Lambda method and makes it possible to apply to monitor a static behavior of large scaled Infra-structures, such as dams, tall buildings, road slops.

  • PDF

진동형 분진 최소착화에너지측정장치에서 분진 응집현상이 미치는 영향 (Effects of the Powder Agglomeration on Vibrating Minimum Ignition Energy Measurement System for Powder)

  • 최광석;정재희;황명환;우인성;목연수;최충석
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.48-53
    • /
    • 1999
  • It is widely recognized that Hartmann tube for measuring the minimum ignition energy(MIE) of powder. But It requires long time and operational skills for measuring. As a variety of new fine powders are being produced day by day in industry, Japen has been developing a measurement system which employs a new method to create a dust/air mixture in a miniature combustion box. In this system, by vibration, the powder is successively fed downward through a hopper made up of metal mesh, and then it is formed into a thin, certain-like, dust/air mixture. With this new apparatus, three types of powder-Lycopodium, Anthraquinone, and Polyacry-lonitrile-were tested and the data of MIE were compared with those of a conventional apparatus (the Hartmann tube). Two of them agreed satisfactory, but the other, Anthraquinone, showed quite different values. It is guessed that the agglomerations of the powder particles appear because of particle shapes, static-charge and humidity.

  • PDF

Results of the key comparison in absolute pressure from 1 Pa to 1000 Pa

  • Hong, Seung-Soo;Shin, Yong-Hyeon;Chung, Kwang-Hwa;A. P. Miiller
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권3호
    • /
    • pp.109-115
    • /
    • 2002
  • This paper describes a CCM key comparison of low absolute-pressure standards at seven National Measurement Institutes that was carried out during the period March 1998 to September 1999 in order to determine their degrees of equivalence at pressures in the range 1 Pa to 1000 Pa. The Korea Research Institutes of Standards and Science(KRISS) participated from 10 Pa to 1000 Pa pressure range in 1999. The primary standards, which represent two principal measurement methods, included five liquid-column manometers and four static expansion systems. The transfer standard package consisted of four high-precision pressure transducers, two capacitance diaphragm gauges to provide high resolution at low pressures, and two resonant silicon gauges to provide the required calibration stability.

  • PDF

유동 저항에 따른 원심홴의 선정 (Selection of Centrifugal Fan for Flows with Down-Stream Resistance)

  • 김재원;장동희;안은영
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.44-48
    • /
    • 2006
  • Comprehensive experimental works are carried out for the optimal design of a centrifugal blower adopted in an indoor unit of an air-conditioner. The models for consideration are typical multi-blade turbo blower and limit loaded one, respectively. The main interest lies on the fluid dynamics performance when the blower Is installed in the practical system. The methodologies are an experimental estimations with a wind tunnel for blower performance and PIV measurement for the detail flow information. A centrifugal blower with limit loaded fan shows pronounced performances in terms of the flow rate and static pressure rise and the reason is explained by the precise measurement of the flows between blades using PIV. Consequently, it is found that the blower is proper for the flows with a resistance in down stream such as a heat exchanger.