Evaluation of Bearing Capacity of Piles in Sand Using Pile Driving Analyzer (동재하시험을 이용한 모래지반의 말뚝지지력 산정)

  • 이우진;석종수
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.145-154
    • /
    • 1997
  • Though the static pile load tests gives the mosts accurate estimation on the load carrying capacity of tested pile, it appears time-consuming and not economical. Many test methods using equipments, such as Pile Driving Analyzer(PDA), STATNAMIC, and Osterberg cell, have been introduced in Korea, and pile best using PDA has been gaining popularity because of iris fast and simple operation. Static and dynamic tests results on the piles installed in the granular coils were analyzed to investigate the effect of geometrical damping on the estimated load carrying capacity. It was found that the CAPWAP analysis without considering geometrical damping effect underestimates the pile capacity by 30~60% under certain conditions. It was observed that the underestimation of pile capacity by CAPWAP occurs on the piles installed in the water-borne granular boils by SIP methods. When Smith skin damping value(SSkn) greater than 1.0 sec/m is obtained in CAPWAP analysis, it may reflect the large possibility of underestimation of pile capacity. The introduction of the geometircal damping option in CAPWAP analysis gives reasonable pile capacity, compared with the static pile load test results, and reduces the SSb value under 0.7 sec/m.

  • PDF

A Static Analyzer for Detecting Memory Leaks based on Procedural Summary (함수 요약에 기반한 메모리 누수 정적 탐지기)

  • Jung, Yung-Bum;Yi, Kwang-Keun
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.7
    • /
    • pp.590-606
    • /
    • 2009
  • We present a static analyzer that detects memory leaks in C programs. It achieves relatively high accuracy at a relatively low cost on SPEC2000 benchmarks and several open-source software packages, demonstrating its practicality and competitive edge against other reported analyzers: for a set of benchmarks totaling 1,777 KLOCs, it found 332 bugs with 47 additional false positives (a 12.4% false-positive ratio), and the average analysis speed was 720 LOC/sec. We separately analyze each procedure's memory behavior into a summary that is used in analyzing its call sites. Each procedural summary is parameterized by the procedure's call context so that it can be instantiated at different call sites. What information to capture in each procedural summary has been carefully tuned so that the summary should not lose any common memory-leak-related behaviors in real-world C program. Because each procedure is summarized by conventional fixpoint iteration over the abstract semantics ('a la abstract interpretation), the analyzer naturally handles arbitrary call cycles from direct or indirect recursive calls.

Characteristic Analysis of Motor using VIS (VIS를 이용한 전기기기 특성 해석)

  • Lee, I.Y.;Kim, Y.W.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.126-129
    • /
    • 2004
  • This paper presents the way to analyze the static and dynamic characteristics of the Compound motor and 3 phase slip ring motor using VIS (Virtual Instrument System) and Agilent VEE, GUI(Graphics User Interface) tool. This method is composed of real time measuring of various characteristics, which can't measure using analog meter and analyzer, and presenting and analyzing the static and dynamic characteristics by table, which calculates the measured parameter. Also, this can apply to the various parts.

  • PDF

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.

Static Analysis Tools Against Cross-site Scripting Vulnerabilities in Web Applications : An Analysis

  • Talib, Nurul Atiqah Abu;Doh, Kyung-Goo
    • Journal of Software Assessment and Valuation
    • /
    • v.17 no.2
    • /
    • pp.125-142
    • /
    • 2021
  • Reports of rampant cross-site scripting (XSS) vulnerabilities raise growing concerns on the effectiveness of current Static Analysis Security Testing (SAST) tools as an internet security device. Attentive to these concerns, this study aims to examine seven open-source SAST tools in order to account for their capabilities in detecting XSS vulnerabilities in PHP applications and to determine their performance in terms of effectiveness and analysis runtime. The representative tools - categorized as either text-based or graph-based analysis tools - were all test-run using real-world PHP applications with known XSS vulnerabilities. The collected vulnerability detection reports of each tool were analyzed with the aid of PhpStorm's data flow analyzer. It is observed that the detection rates of the tools calculated from the total vulnerabilities in the applications can be as high as 0.968 and as low as 0.006. Furthermore, the tools took an average of less than a minute to complete an analysis. Notably, their runtime is independent of their analysis type.

Resonance Type Acoustic Emission Signal Analyzing Method for the failure detection of the composite materials (복합재료의 파손 감지를 위한 동조형 음향방출 신호분석 기법)

  • Lee, Chang-Hun;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.30-36
    • /
    • 2004
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on the non-destructive testing methods of the composite materials has become an important research area for improving their reliability and safety. In this paper, the AE signal analyzer with the resonance circuit to extract the specified frequency of the acoustic emission signal were designed and fabricated. The noise levels of the fabricated AE signal analyzer by the disturbance such as impact or mechanical vibration had a very small value comparable to those of the conventional AE signal analyzer. Also, the fabricated AE signal analyzer was proved to have about the same crack detection capabilities with the conventional AE signal analyzer under the static and dynamic tensile tests of the composite materials.

CASE STUDIES ON THE CONSTRUCTION CONTROL OF FILE FOUNDATION BY PILE DRIVING ANALYZER (항타분석기에 의한 말뚝시공관리 사례)

  • 이우진;이인모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.79-86
    • /
    • 1994
  • Two case studies on the application of Pile Driving Analyzer (PDA) are introduced. It is shown that the PDA and CAPWAP are effective tools for the construction control of pile foundations with minimum cost and time. The PDA and CAPWAP techniques are able to evaluate the performace of hammer and driving system: to check the stresses in the pile due to driving: to determine the damage of pile: to predict the ultimate bearing capacity of pile: to estimate the important soil paramaters such as the soil resistance, quake, and damping etc.: and to provide the load - displacement curve from the simulated static load test. Theoretical backgrounds of wave mechanics is briefly reviewed and the methodology of construction control using the PDA is also discussed.

  • PDF

Measurement of Effective Linewidth for Ca-Zr Substituted YIG (Ca-Zr치환 YIG의 유효 선폭 측정)

  • 김약연;한진우;한기평;김덕준;이상석;최태구
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • The effective linewidth was measured using the conventional cavity perturbation method at 9.43 GHz in room temperature for Ca-Zr substituted yttrium iron garnet plate. The experimental set-up consists of the network analyzer, the electromagnet and the cylimdrical TE001 cavity. Measurement was performed in the static magnetic field perpendicular to the sample plane. The real and imaginary parts of diagonal component of the microwave susceptibility tensor are obtained from the resonance frequency and the quality factor Q of the cavity. Variations of the effective linewidth was qualitatively explained with the spin wave scattering theory.

  • PDF

An Acquisition and Analysis Equipment of Dynamic/Static Data on a Rotating Vibration (회전체 진동 데이터의 AC/DC 성분 데이터 획득 및 분석 장치)

  • Lee, Jung Suk;Ryu, Deung Ryeol;Lee, Cheol
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.127-137
    • /
    • 2009
  • This paper is proposed that in-output Digital module is acquired a vibration signal of a rotating machinery by Data Acquisition System. The module is designed to get ride of nose through low pass filter on the vibration signal from sensors and set the gain value for being able to sampling AC to DC, and also the sampled data by sampler and the conversed data by DIP/FPGA is supplied to the analyzer for analysis at a software tool. The DIP(Digital Signal Processor) of the Digital input/output Board makes Average voltage, Peak to Peak voltage, RMS(Root Mean Square) and Gap voltage, also FFT(Fast Fourier Transform) for rotating vibration diagnosis.