• Title/Summary/Keyword: Standards of outdoor temperature

Search Result 28, Processing Time 0.026 seconds

Performance Analysis of Strength Development of FRC Base Depending on Maturity (적산온도에 의한 FRC 기층의 강도발현 성능 분석)

  • Choi, Sung-Yong;Park, Young-Hwan;Jung, Woo-Tai
    • International Journal of Highway Engineering
    • /
    • v.18 no.1
    • /
    • pp.13-21
    • /
    • 2016
  • PURPOSES : In this study, we analyzed the compressive strength characteristics of lean base concrete in relation to changes in the outdoor temperature after analyzing the cold and hot weather temperature standards and calculated the minimum and maximum temperatures when pouring concrete. We examined the rate of strength development of lean base concrete in relation to the temperature change and derived an appropriate analysis formula for FRC base structures by assigning the accumulated strength data and existing maturity formula. METHODS : We measured the strength changes at three curing temperatures (5, 20, and $35^{\circ}C$) by curing the concrete in a temperature range that covered the lowest temperature of the cold period, $5^{\circ}C$, to the highest temperature of the hot period, $35^{\circ}C$. We assigned the general lean concrete and FRC as test variables. A strength test was planned to measure the strength after 3, 5, 7, 14, and 28 days. RESULTS : According to the results of compressive strength tests of plain concrete and FRC in relation to curing temperature, the plain concrete had a compressive strength greater than 5 MPa at all curing temperatures on day 5 and satisfied the lean concrete standard. In the case of FRC, because the initial strength was substantially reduced as a result of a 30% substitution of fly ash, it did not satisfy the strength standard of 5 MPa when it was cured at $5^{\circ}C$ on day 7. In addition, because the fly ash in the FRC caused a Pozzolanic reaction with the progress into late age, the amount of strength development increased. In the case of a curing temperature of $20^{\circ}C$, the FRC strength was about 66% on day 3 compared with the plain concrete, but it is increased to about 77% on day 28. In the case of a curing temperature of $35^{\circ}C$, the FRC strength development rate was about 63% on day 3 compared with the plain concrete, but it increased to about 88% on day 28. CONCLUSIONS : We derived a strength analysis formula using the maturity temperatures with all the strength data and presented the point in time when it reached the base concrete standard, which was 5 MPa for each air temperature. We believe that our findings could be utilized as a reference in the construction of base concrete for a site during a cold or hot weather period.

Effect of Heat Treatment Conditions on Color Change and Termite Resistance of Heat-Treated Wood (열처리 조건이 목재의 색상 변화 및 흰개미 저항성에 미치는 영향)

  • Ra, Jong-Bum;Kim, Ki-Bum;Leem, Kyung-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.370-377
    • /
    • 2012
  • This study was conducted to investigate the color change of heat-treated wood made of Korean pine (Pinus koraiensis S. et Z.), and lodgepole pine (Pinus contorta Dougl). The wood samples were heat-treated at 9 different treatment combinations of temperature (170, 180, 200, 220, and $230^{\circ}C$), and time (90, 120, 180, 240, 270 min.) set up by a response surface method. Wood color was measured using a colorimeter, and the samples were installed for evaluating the resistance of termite in the field test sites set up in Jinju. The lightness decreased with the increase of treatment temperature and treatment time. The color differences were evaluated by the method of National Bureau of Standards (NBS), and response surface models to predict the color change were fitted as a function of treatment temperature and treatment time. The $R^2$ values of the fitted models of heat-treated Korean pine and lodgepole pines were 0.92, and 0.88, respectively, showing the potential way for the prediction of color changes. Severe damage was found from the samples in the field test site, which means that the manufactured heat-treated wood did not show the termite resistance enough for the outdoor use.

An Analysis of Thermal Comforts for Pedestrians by WBGT Measurement on the Urban Street Greens (도심 가로 녹음의 습구흑구온도(WBGT) 측정을 통한 보행자 열쾌적성 효과 분석)

  • Ahn, Tong-Mahn;Lee, Jae-Won;Kim, Bo-Ram;Yoon, Ho-Seon;Son, Seung-Woo;Choi, Yoo;Lee, Na-Rae;Lee, Ji-Young;Kim, Hae-Ryung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.22-30
    • /
    • 2013
  • This study aims to measure the thermal comfort effects of urban street trees. As the usual dry bulb air temperature does not indicate properly how the average pedestrian feels the heat of a typical summer day under the strong sunshine, we adopted the Wet Bulb Globe Temperature(WBGT). WBGT involves black globe temperature to measure the direct radiation of sun beams on our bodies, for example our heads. We measured temperatures on very sunny and hot summer days, August 3, 4, and 7, 2012, on the urban streets of Seoul, Korea. Wet bulb, globe, and dry bulb temperatures were measured under direct sunlight from 1 O'clock to 5 O'clock pm. Globe and dry bulb temperatures were measured under street tree shades nearby during the same hours. Then the WBGTs were calculated with the formulae, one for sunny outdoor spaces, and the other for shaded outdoor spaces or indoor. The results are compared with the Korean Standards Association(KS A ISO 7243). The major findings were: 1) On very sunny and hot summer days in Seoul, street tree shades lower the WBGT about 1 to 4 degrees, 2) during the hours of 3 and 4 O'clock in the afternoon, the WBGT under the tree shades are about 3 to 4 degrees lower compared to those under sunshines(approx. 29 to 32 degrees respectively), 3) This difference makes a major thermal comfort for urban pedestrians because senior citizens or weak persons are recommended to move indoor, and even healthy people are recommended stop outdoor sports and take rests in the shades when WBGT is about 32. On the other hand, if the WBGT is around 29, or 3 degrees lower, slower walking, light works or sports are allowable, 4) On site questionnaire survey confirms the thermal comforts under the tree shades, and we even could not get survey subjects on the sunny parts of the sidewalks, 5) We strongly recommend change of guidelines for urban street trees from "one row of street trees on 6m~8m intervals" to "street trees to make continuous shades".

The audit method of cooling energy performance in office building using the Simple Linear Regression Analysis Model

  • Park, Jin-Young;Kim, Seo-Hoon;Jang, Cheol-Young;Kim, Jong-Hun;Lee, Seung-Bok
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.13-20
    • /
    • 2015
  • Purpose: In order to upgrade the energy performance of existing building, energy audit stage should be implemented first because it is useful method to find where the problems occur and know how much time and cost consumption for retrofit. In overseas researches, three levels of audit is proposed whereas there are no standards for audit in Korea. Besides, most studies use dynamic simulation in detail like audit level 3 even though the level 2 can save time and cost than level 3. Thus, this paper focused on audit level 2 and proposed the audit method with the simple linear regression analysis model. Method: Two parameters were considered for the simple regression analysis, which were the monthly electric use and the mean outdoor temperature data. The former is a dependent variable and the latter is a independent variable, and the building's energy performance profile was estimated from the regression analysis method. In this analysis, we found the abnormal point in cooling season and the more detailed analysis were conducted about the three heat source equipments. Result: Comparing with real and predicted models, the total consumption of predicted model was higher than real value as 23,608 kWh but it was the results that was reflected the compulsory control in 2013. Consequently, it was analyzed that the revised model could save the cooling energy as well as reduce peak electric use than before.

Characteristics of the Newly Developed Rain Shelter for Grapevine and Growth of 'Campbell Early' (신개발 포도 비가림 시설의 특성과 '캠벌얼리'의 생육)

  • Lee, Yun Sang;Kim, Seung Deok;Lee, Seok Ho;Hong, Seong Taek;Lee, Jae Wung;Hong, Eui Yon;Kim, Dae Il
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.252-257
    • /
    • 2015
  • Fruit cracking and vine leaf spot of grapes tend to occur when the plants were directly exposed to rain under outdoor culture. Rain shelter facility can be an alternative method to prevent the cracking and disease of grape, but it also has some limitations in practical usages. We designed rain shelter facility which can completely shut out the rain and ventilate naturally, and it was upgraded to meet the standards of disaster prevention against snow and wind load. The newly developed rain shelter has two-story roof structure, and the $2^{nd}$ floor roof was equipped over $1^{st}$ floor roof at a distance of 40cm. For natural ventilation and water proof, the upper roof protruded about 50cm from the ridge of a $1^{st}$ floor roof. The various tests were carried to examine such as grape quality, brown spot and fruit cracking of Campbell Early under the conventional and the newly developed rain shelter facility which was built about $100{\ss}{\check{S}}$. In comparison of temperature between the conventional and the newly developed rain shelter facility when outside temperature was more than $34^{\circ}C$, the inside temperature was recorded as $40.7^{\circ}C$ and $37.4^{\circ}C$, respectively. There was no significant difference between the two facilities when outside was below $32^{\circ}C$ The quality such as soluble solids and marketable fruit was increased, and fruit cracking of grapes and vine leaf spot also drastically diminished in the newly developed rain shelter.

A Improvement Scheme for the Illumination of Surrounding Lake Scenery in a Historic and Cultural City - Focusing on the Bomun Lake in Kyung Ju City - (역사문화도시의 수변경관 조명(照明) 개선방안 - 경주시 보문호를 대상으로 -)

  • Lee, Yeon-So;Kim, Choong-Sik;Choi, Gi-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.1
    • /
    • pp.142-156
    • /
    • 2011
  • This study aims to suggest improvements in night landscape lighting of Bomun Lake, a representative waterfront landscape in Gyeongju which is the city designated as UNESCO World Heritage in December 2000. This study divided the area into three types of sections-that is, road section, walking section, and landscape section- based on the present condition of land use and users of the Bomun Lake area. In addition, this study classified the lightingtypes by section into nine lighting types-that is, road, crossroad, parking lot, pedestrian passage, trail, sculpture, tree, waterfront deck-by comparing them to the park lighting types suggested by the KS A illuminance standards, and examined the problems of the current Bomun Lake lighting base on the standards. By using this as basic data, this study established relevant plans and collected research material. This study suggested directions of each of the three sections and improvements in illuminance, color temperature, creating methods of each of the nine lighting types to the night Lighting planning of the Bomun Lake area reflecting the landscape characteristics of Gyeongju, a historical, cultural city.

Study on the Sun Protection Factor(SPF) Test Method for Sun Product Water Resistance (내수성 자외선 차단제의 자외선 차단지수 평가방법 연구)

  • Mun, Kyoung-Jin;Kim, So-Un;Mun, Ju-Hee;Kim, Soo-Jin;Kim, A-Young;Moon, Tae-Kee;Kim, Nam-Soo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.1
    • /
    • pp.63-66
    • /
    • 2008
  • Sunscreen is usually used by people when they are at the beach or outdoor swimming pools. Since the existing methods of and standards for measuring the effects of blocking ultra violet rays do not employ water resistance test methods, the establishment of a water resistance SPF test method is required. In this study, to standardize the SPF evaluation methods for a water resistant sunscreen, proposed measurement methods in this study were compared with those of foreign countries. Selected water resistance SPF experiments confirmed the product's suitability and a verification test was then conducted by establishing the variables of water resistance SPF measurement methods. In the comparative experiment on water resistance SPF given a water temperature of $23{\sim}32$ degrees centigrade showed that temperature did not have any statistically significant effect on water resistance SPF. The changing water flow also did not have any statistically significant effect on the water resistance SPF. Therefore, continuous 20 min water circulation is deemed appropriate as an alternative to the subject's usual activity.

Characteristics of Flame Retardent and Mothproof Conservation of Microwave Heated wood (마이크로파 가열 목재의 방염·방충 복합 보존처리 특성)

  • Kim, Chong-Gun;Park, Cheul-Woo;Yoon, Tae-Ho;Lim, Nam-Gi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.234-246
    • /
    • 2013
  • It was found that test piece heated rapidly by 3 kW microwave for 5 minutes satisfies the targeted temperature and the percentage of moisture content, and the highest rate of weight increase is obtained in case of 120 minute immersion in the mixture of phosphates and heterocyclic compounds, from the result of such analysis as: kiln drying schedule, flame retardent by flammability test, insect resistance by termites, and permeability of combined penetrant for the wood after assigning multifunctional finish by immersing conifer structural frame, which is used for the frame work of wooden house and indoor/outdoor finishing in flame retardant and insect repellent materials mixture with the remaining heat of microwave. In addition, after a test of flame retardent treated item, it was identified that every mixture of phosphates corresponds with the standards of flame retardent, and upon investigation of moritality of 7 days after putting termites, it was showed that test piece immersed in the mixture of phosphates and heterocyclic compounds has the best characteristics, showing over 96% of high moritality. From the analysis of inward permeability of combined penetrant for the wood, it was decided that excellent performance in the flame retardent and insect resistance of the wood revealed due to full penetration of combined penetrant as it was found that combined penetrant penetrated through the whole inner cells of the wood.