• 제목/요약/키워드: Standardized uptake value

검색결과 113건 처리시간 0.067초

경도인지장애와 알츠하이머병 환자의 18F-fludeoxyglucose PET 표준 섭취계수율에 대한 체적 및 피질 표면 기반 관심영역 분석 (Region of Interest Analysis for Standardized Uptake Value Ratio of 18F-fludeoxyglucose PET: Mild Cognitive Impairment and Alzheimer's Disease)

  • 김선직;윤의철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권6호
    • /
    • pp.237-242
    • /
    • 2018
  • $^{18}F$-fludeoxyglucose PET (FDG-PET) can help finding an abnormal metabolic activity in brain. In this study, we evaluated an efficiency of volume- and cortical surface-based analysis which were used to determine whether standardized uptake value ratio (SUVR) of FDG-PET was different among Alzheimer's disease (AD), mild cognitive impairment (MCI), and healthy control (HC). Each PET image was rigidly co-registered to the corresponding magnetic resonance imaging (MRI) using mutual information. All voxels of the co-registered PET images were divided by the mean FDG uptake of the cerebellum cortex which was thresholded by partial volume effect (>0.9). Also, the SUVR value of each vertex was linearly interpolated from volumetric SUVR image which was thresholded by gray matter partial volume effect (>0.1). Lobar mean values were calculated from both volume- and cortical surface-based SUVRs. Statistical analysis was conducted to compare two measures for AD, MCI and HC groups. Even though the results of volume (SUVR_vol) and cortical surface-based SUVR (SUVR_surf) analysis were not significantly different from each other, the latter would be better for detecting group differences in SUVR of PET.

Maximum standardized uptake value at pre-treatment PET in estimating lung cancer progression after stereotactic body radiotherapy

  • Park, Jisun;Choi, Yunseon;Ahn, Ki Jung;Park, Sung Kwang;Cho, Heunglae;Lee, Ji Young
    • Radiation Oncology Journal
    • /
    • 제37권1호
    • /
    • pp.30-36
    • /
    • 2019
  • Purpose: This study aimed to identify the feasibility of the maximum standardized uptake value (SUVmax) on baseline 18F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) as a predictive factor for prognosis in early stage primary lung cancer treated with stereotactic body radiotherapy (SBRT). Materials and Methods: Twenty-seven T1-3N0M0 primary lung cancer patients treated with curative SBRT between 2010 and 2018 were retrospectively evaluated. Four patients (14.8%) treated with SBRT to address residual tumor after wedge resection and one patient (3.7%) with local recurrence after resection were included. The SUVmax at baseline PET/CT was assessed to determine its relationship with prognosis after SBRT. Patients were divided into two groups based on maximum SUVmax on pre-treatment FDG PET/CT, estimated by receiver operating characteristic curve. Results: The median follow-up period was 17.7 months (range, 2.3 to 60.0 months). The actuarial 2-year local control, progression-free survival (PFS), and overall survival were 80.4%, 66.0%, and 78.2%, respectively. With regard to failure patterns, 5 patients exhibited local failure (in-field failure, 18.5%), 1 (3.7%) experienced regional nodal relapse, and other 2 (7.4%) developed distant failure. SUVmax was significantly correlated with progression (p = 0.08, optimal cut-off point SUVmax > 5.1). PFS was significantly influenced by pretreatment SUVmax (SUVmax > 5.1 vs. SUVmax ≤ 5.1; p = 0.012) and T stage (T1 vs. T2-3; p = 0.012). Conclusion: SUVmax at pre-treatment FDG PET/CT demonstrated a predictive value for PFS after SBRT for lung cancer.

핵의학 융합영상의 표준섭취계수 차이에 관한 연구 (Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine)

  • 김정수;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

비인강암 환자의 예후에서 $2-[18^F]$ Fluoro-2-Deoxy-D-Glucose PET 영상에서 계산되는 Standardized Uptake Value의 의의 (Prediction of Prognosis to Concurrent Chemo-Radiotherapy by Standardized Uptake Value of $2-[18^F]$ Fluovo-2-Deoxy-D-Glucose for Nasopharyngeal Carcinomas)

  • 이상욱;임기천;남순열;김재승;최은경;안승도;신성수;류진숙;김상윤;이봉재;최승호;김성배;문대혁
    • Radiation Oncology Journal
    • /
    • 제23권1호
    • /
    • pp.9-16
    • /
    • 2005
  • 목적 : 원격존기의 전이가 없는 비인강암에서 동시항암화학방사선치료를 시행 받은 환자에서 진단 당시 시행한 양전자단층촬영의 fluorodeoxyglucose (FDG) 섭취정도가 예후에 미치는 영향을 알아보고자 하였다. 대상 및 방법 : 본원에서 원격장기의 전이가 없는 비인강암으로 진단 받고 진단 당시 ($[18^F]$FDG-PET을 시행한 환자는 총 41명이었다. PET 검사는 모두 항암방사선치료 전에 시행되었다. FOG 섭취 정도를 알아보기 위해서 종양 내에서 측정된 최대 standardized uptake value (SUV)를 측정하였다. 결과 : 항암화학방사선지료 후 모든 환자는 완전반응을 보였다. 전체 41명 중에서 10명이 재발하였는데 재발하지 않은 환자의 $SUV_{max}$ 중앙값은 6.48 (range: $2.31\~26.07$)이었고 재발한 환자의 중앙 $SUV_{max}$$8.55(2.49\~14.81)$이었다. 양 군 간의 5UV의 차이는 p값이 0.0505로 통계적 차이가 관찰되지 않았다. $SUV_{max}$를 중앙값을 기준으로 나누어 보았을 때 $SUV_{max}$가 높은 환자의 3년 생존율이 통계적으로 유의하게 저조하였다($51\%\;{\nu}91\%$, p=0.0070). 결론 : 원격전이가 없는 비인강암에서 항암화학방사선치료를 시행 받은 환자에서 진단 당시 시행한 FDG 섭취 정도는 예후를 예측하는데 유용할 것으로 생각되었다. 따라서 진단 당시 시행한 FDG-PET에서 SUV가 높은 경우(8 이상)에는 좀더 적극적인 치료가 필요할 것으로 생각하였다.

18F-FDG PET-CT 검사에서 췌장암, 췌장염, 정상 췌장에 대한 최대 표준섭취계수의 임상적 기준 설정 (Clinical Reference of the Maximum Standardized Uptake Values to the Pancreatic Cancer, Pancreatitis and Normal Pancreas in the 18F-FDG PET-CT)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권2호
    • /
    • pp.80-86
    • /
    • 2018
  • The aim of this study were to establish the clinical references and guidelines for the maximum standardized uptake ($SUV_{max}$) value of pancreatic cancer, pancreatitis, and normal pancreas in $^{18}F-FDG$ PET-CT examinations for pancreatic disease. For this purpose, we performed the statistical analysis on the descriptive statistics, percentiles and inter quartiles range (IQR), normal distribution, and using the probability density function for pancreatic cancer, pancreatitis, and normal pancreas. As a result, the clinical reference of $SUV_{max}$ for the pancreatic cancer, pancreatitis, and normal pancreas was more than 3.45, 1.91 to 2.62, and less than 1.91, respectively. Also, optimal cut-off value for applying the dual time point PET-CT examination was determined to be 2.62. The results of this study are summarized as follows: first, we suggests the clinical reference and guideline for the pancreatic cancer, pancreatitis, and normal pancreas, and second, suggests a scientific approach to improve diagnostic accuracy of pancreatic disease by deviating from an approximate experience approach.

PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향 (Effect of Extended Field of View on Measurements of Standardized Uptake Value in PET/CT)

  • 박순기;남기표;김경식;신상기
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.82-85
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of extended CT field of view (FOV) on PET/CT of Standardized uptake value (SUV) when imaging extends beyond the CT FOV. Materials and Methods: CT images were reconstructed at different FOV sizes (500 and 700 mm). Two sets of CT images were reconstructed from the CT projection data by using two FOV sizes. Twenty patients were used in this study. PET images were reconstructed using attenuation maps with 500 mm CT FOV and 700 mm extended CT FOV images. Region of interests (ROIs) drawn on the PET images. In addition, twenty patients' PET images reconstructed by 500 mm CT FOV and 700 mm extended CT FOV were compared with $SUV_{max}$. Results: When using attenuation maps with 700 mm extended CT FOV, the $SUV_{max}$ analysis of liver (p=0.000), lung (p=0.007), mediastinum (p=0.001) were statistically significant. Conclusions: 700 mm extended CT FOV helps to recover the true activity distribution in the PET emission data. In addition, 700 mm extended CT FOV has affected SUV measurement of liver, lung, mediastinum.

  • PDF

물질의 종류에 따른 표준섭취계수의 변화에 관한 연구 (A Study of Standarzied Uptake Value Change on the Type of Mateiral)

  • 김기진;김종일;배석환
    • 한국산학기술학회논문지
    • /
    • 제12권8호
    • /
    • pp.3572-3578
    • /
    • 2011
  • 양전자방출단층촬영에서 표준섭취계수는 종양의 진단에 사용이 되는 지표이다. 표준섭취계수는 여러 인자에 의해 변화한다. 본 연구에서는 Philips사의 GEMINI TF PET/CT를 이용하여 물질에 따른 영상의 왜곡 및 표준섭취계수의 변화에 대하여 실험하였다. 물질별 표준섭취계수의 변화는 스테인레스보정물은 1.8, 스텐트는 1.4, 요오드성조영제는 2.4, 황산바륨은 2.6, 석고는 1.6, 파라핀은 1.4 이였다. 황산바륨 일수록 농도가 높을수록 영상의 왜곡은 크게 나타났다. 실험의 결과 원자번호가 낮은 금속성 물질이나 농도가 낮은 조영제의 경우 큰 영향은 없었다. 그러나 검사전 반드시 금속성 물질을 제거하거나 조영제의 유무를 확인하여 영상의 왜곡 및 표준섭취계수의 변화를 최소화 해야할 것이다.

폐암과 폐 염증성질환의 동적양전자방출단층검사 (Dynamic $^{18}F-FDG$ PET)의 유용성 (Usefulness of Dynamic $^{18}F-FDG$ PET Scan in Lung Cancer and Inflammation Disease)

  • 박훈희;노동욱;김세영;동경래;이민혜;강천구;임한상;오기백;김재삼;이창호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.249-255
    • /
    • 2006
  • 목 적: 양전자방출단층검사(Fluorine-18 2-Deoxy-D-Glucose positron emission tomography : $^{18}F-FDG$ PET)는 가시적 영상분석과 반정량적 섭취계수 분석 방법을 사용하여 폐의 염증성 질환과 폐암을 구별 및 진단하는 데 유용하다. 일반적으로 표준화섭취계수(Standardized Uptake Value : SUV)가 폐 질환의 진단에 사용되지만, 이는 폐 조직에 있어서 반정량적, 정량적 분석을 통한 동적인 정보를 포함하지 않는다. 그러므로, 본 연구는 $^{18}F-FDG$ PET 검사에서 폐 질환의 동적 섭취 분석이 보다 정확한 대상질환의 진단을 유용하게 할 수 있을 것이라는 가정하에 시간-방사능 곡선(Time-Activity Curve: TAC), 표준화섭취계수-동적곡선(Standardized Uptake Value-Dynamic Curve : SUV-DC), 패트락 분석법(Patlak analysis : Glucose Metabolic Rate(MRGlu))을 토대로 얻은 분석방법을 이용하여 진단적 유용성을 평가하였다. 대상 및 방법: 폐 질환을 가진 17명의 환자를 대상을 하여, 각각 60분간 Dynamic $^{18}F-FDG$ PET검사를 시행하였다. 획득한 정보를 통하여 폐질환의 형태를 따라 관심영역(Region of Interest: ROI)를 그린 후, 반정량적 분석인 TAC, SUV-DC와 정량적 분석인 Patlak analysis를 각각의 군에 따라 분석하여 비교 분석하였다. 결 과: Dynamic $^{18}F-FDG$ PET을 통한 분석결과, TAC 형태는 초기 혈류상에서 폐의 염증성 질환과 폐암의 구분이 어려웠으나, 시간이 지날수록 폐암의 곡선이 염증성 질환의 경우보다 확연히 증가하였다. SUV-DC의 경우는 TAC 형태와 거의 유사한 형태를 가졌다. Patlak analysis 분석결과, 대동맥 영역에서는 폐의 염증성 질환이 폐암보다 높은 혈액 방사능을 보였으나 시간이 지남에 따라 염증성 질환의 혈액 방사능이 극히 낮아졌다. 반면, 병변 조직에서는 폐암이 가장 높은 섭취를 보였으며 폐의 염증성 질환은 중간 정도에 머물렀다. 결 론: TAC와 SUV-DC 분석에서 폐암과 폐의 염증성 질환은 각각 고유한 그래프 형태를 띠었으며 Patlak analysis에서 역시 주목할 만한 차이를 보였다. 따라서 이러한 분석법을 토대로 좀더 깊이 있는 연구가 진행된다면 비침습적으로 폐의 질환을 구별하는 데 보다 적절하고 유용한 진단적 정보를 얻을 수 있을 것이다.

  • PDF

18F-2-Deoxy-2-Fluoro-D-Glucose Positron Emission Tomography: Computed Tomography for Preoperative Staging in Gastric Cancer Patients

  • Youn, Seok Hwa;Seo, Kyung Won;Lee, Sang Ho;Shin, Yeon Myung;Yoon, Ki Young
    • Journal of Gastric Cancer
    • /
    • 제12권3호
    • /
    • pp.179-186
    • /
    • 2012
  • Purpose: The use of 18F-2-deoxy-2-fluoro-D-glucose positron emission tomography-computed tomography as a routine preoperative modality is increasing for gastric cancer despite controversy with its usefulness in preoperative staging. In this study we aimed to determine the usefulness of preoperative positron emission tomography-computed tomography scans for staging of gastric cancer. Materials and Methods: We retrospectively analyzed 396 patients' positron emission tomography-computed tomography scans acquired for preoperative staging from January to December 2009. Results: The sensitivity of positron emission tomography-computed tomography for detecting early gastric cancer was 20.7% and it was 74.2% for advanced gastric cancer. The size of the primary tumor was correlated with sensitivity, and there was a positive correlation between T stage and sensitivity. For regional lymph node metastasis, the sensitivity and specificity of the positron emission tomography-computed tomography were 30.7% and 94.7%, respectively. There was no correlation between T stage and maximum standardized uptake value or between tumor markers and maximum standardized uptake value. Fluorodeoxyglucose uptake was detected by positron emission tomography-computed tomography in 24 lesions other than the primary tumors. Among them, nine cases were found to be malignant, including double primary cancers and metastatic cancers. Only two cases were detected purely by positron emission tomography-computed tomography. Conclusions: Positron emission tomography-computed tomography could be useful in detecting metastasis or another primary cancer for preoperative staging in gastric cancer patients, but not for T or N staging. More prospective studies are needed to determine whether positron emission tomography-computed tomography scans should be considered a routine preoperative imaging modality.

Evaluation of Therapeutic Efficacy using [18F]FP-CIT in 6-OHDA-induced Parkinson's Animal Model

  • Jang Woo Park;Yi Seul Choi;Dong Hyun Kim;Eun Sang Lee;Chan Woo Park;Hye Kyung Chung;Ran Ji Yoo
    • 대한방사성의약품학회지
    • /
    • 제9권1호
    • /
    • pp.3-8
    • /
    • 2023
  • Parkinson's disease is a neurodegenerative disease caused by damage to brain neurons related to dopamine. Non-clinical animal models mainly used in Parkinson's disease research include drug-induced models of 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine and 6-hydroxydopamine, and genetically modified transgenic animal models. Parkinson's diagnosis can be made using brain imaging of the substantia nigra-striatal dopamine system and using a radiotracer that specifically binds to the dopamine transporter. In this study, 18F-N-(3-fluoropropyl)-2β-carboxymethoxy-3β-(4-iodophenyl) nortropane was used to confirm the image evaluation cutoff between normal and parkinson's disease models, and to confirm model persistence over time. In addition, the efficacy of single or combined administration of clinically used therapeutic drugs in parkinson's animal models was evaluated. Image analysis was performed using the PMOD software. Converted to standardized uptake value, and analyzed by standardized uptake value ratio by dividing the average value of left striatum by the average value of right striatum obtained by applying positron emission tomography images to the atlas magnetic resonance template. The image cutoff of the normal and the parkinson's disease model was calculated as SUVR=0.829, and it was confirmed that it was maintained during the test period. In the three-drug combination administration group, the right and left striatum showed a high symmetry of more than 0.942 on average and recovered significantly. Images using 18F-N-(3-fluoropropyl)-2β-carboxymethoxy-3β-(4-iodophenyl) nortropane are thought to be able to diagnose and evaluate treatment efficacy of non-clinical Parkinson's disease.