• Title/Summary/Keyword: Standard service model

Search Result 522, Processing Time 0.028 seconds

A numerical study on the performance of the smoke exhaust system according to the smoke exhaust method in emergency station for railway tunnel (철도터널 구난역의 제연방식에 따른 제연성능에 관한 수치 해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Seo, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.845-856
    • /
    • 2017
  • In the long railway tunnel, in order to secure safety in case of fire, it is required a emergency station. However, there is no standard or research results on smoke exhaust method and exhaust flow rate in emergency station, so it is necessary to study the smoke exhaust system for emergency station. In this study, we are created a numerical analysis model for emergency station where the evacuation cross passage connected to the service tunnel or the relative tunnel was installed at regular intervals (40 m intervals). And the fire analysis are carried out by varying the fire intensity (15, 30MW), the smoke exhaust method (only air supply, forced air supply and exhaust, forced air exhaust only), and the air flow rate (7, 14, $40m^3/s$). From the results of fire analysis, temperature and CO concentration are analyzed and ASET based on the limit temperature are compared at various condition. As a result, in the case with fire intensity of 15 MW, it is shown that a sufficiently safe evacuation environment can be ensured by applying forced air supply and exhaust method or forced air exhaust only method when the air flow rate is $7m^3/s$ above. In case of fire intensity of 30 MW, it is impossible to maintain the safety evacuation environment for more than 900 seconds when the exhaust air volume is below $14m^3/s$. And when the air flow rate is $40m^3/s$, the exhaust port is disposed at the side portion of the upper duct, which is most advantageous for securing the temperature-based safety.

Abolition of restrictions and research on precondition for nominating drone photographing free area (규제혁파, 드론 촬영 자유구역 지정을 위한 선결조건 연구)

  • Seok, Geum-Chan;Park, Gye-Soo;Nam, Soung-Ho;Kim, Young-Ki
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.209-217
    • /
    • 2020
  • The background of the research is the following. With the prosperity of drone industry, the government has been actively promoting measures to nominate 'drone photographing free areas'. However, existing laws, and procedures are rather unclear with related environmental factors in discordance with one another. Hence, voices in need for establishing a clear precondition for nominating drone photography free area have been rising. The purpose of the research is to provide measures for the preconditions to establish photography free areas for convenient drone photographing. The research utilizes literary methods, conducting focus group interviews to coordinate with specialists who can participate and discuss so that they can provide improvement measures. The research renders improvement measures in different sectors including 2x items in aviation security law, 8x items in free area nomination and procedure, 4x items in infrastructure establishment and information management area. The expected effects are the following: by attaching drone photography with aviation security law, nominating photography free area can be linked up with the Ministry of Land Infrastructure and Technology. Secondly, by enlarging photography restricted area to upper mid-air, a three dimensional drone security will be possible. Thirdly, by providing a 'Yongin area standard model', free area nomination will become more easy. Future research will focus on enhancing aviation security law regarding drone photographing. In addition, the promotion to nominate free areas for 33x responsible areas in accordance with the National Intelligence service will be required.

Research on Text Classification of Research Reports using Korea National Science and Technology Standards Classification Codes (국가 과학기술 표준분류 체계 기반 연구보고서 문서의 자동 분류 연구)

  • Choi, Jong-Yun;Hahn, Hyuk;Jung, Yuchul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.169-177
    • /
    • 2020
  • In South Korea, the results of R&D in science and technology are submitted to the National Science and Technology Information Service (NTIS) in reports that have Korea national science and technology standard classification codes (K-NSCC). However, considering there are more than 2000 sub-categories, it is non-trivial to choose correct classification codes without a clear understanding of the K-NSCC. In addition, there are few cases of automatic document classification research based on the K-NSCC, and there are no training data in the public domain. To the best of our knowledge, this study is the first attempt to build a highly performing K-NSCC classification system based on NTIS report meta-information from the last five years (2013-2017). To this end, about 210 mid-level categories were selected, and we conducted preprocessing considering the characteristics of research report metadata. More specifically, we propose a convolutional neural network (CNN) technique using only task names and keywords, which are the most influential fields. The proposed model is compared with several machine learning methods (e.g., the linear support vector classifier, CNN, gated recurrent unit, etc.) that show good performance in text classification, and that have a performance advantage of 1% to 7% based on a top-three F1 score.

The Protective Effects of Statins towards Vessel Wall Injury Caused by a Stent Retrieving Mechanical Thrombectomy Device : A Histological Analysis of the Rabbit Carotid Artery Model

  • Lee, Seung Hwan;Shin, Hee Sup;Oh, Inho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.693-704
    • /
    • 2021
  • Objective : Endovascular mechanical thrombectomy (MT) has been regarded as one of the standard treatments for acute ischemic stroke caused by large vessel occlusion. Despite the wide use of stent retrievers for MT, arterial intimal damage caused when deployed stent is pulled has been a certain disadvantage. We hypothesized that statin could protect and stabilize vessel damage after endovascular MT using a stent retriever. In this animal study, we observed the protective effects of the statins towards MT-induced vessel wall injury. Methods : Twenty-eight carotid arteries of fourteen rabbits were used in the experiments with MT using stent retriever. We divided the rabbits into four groups as follows : group 1, negative control; group 2, positive control; group 3, statin before MT; and group 4, statin after MT. After MT procedures, we harvested the carotid arteries and performed histomorphological and immunohistochemical analyses. Results : In histomorphological analysis with hematoxylin and eosin and Masson's trichrome stain, significant intimal thickening (p<0.05) was observed in the positive control (group 2), compared to in the negative control (group 1). Intimal thickening was improved in the statin-administered groups (groups 3 and 4 vs. group 2, p<0.05). We also observed that statin administration after MT (group 4) resulted in a more effective decrease in intimal thickness than statin administration before MT (group 3) (p<0.05). We performed immunohistochemical analysis with the antibodies for tumor necrosis factor-alpha (TNF-α), cluster of differentiation (CD)11b, and CD163. In contrast to the negative control (group 1), the stained percentage areas of all immunological markers were markedly increased in the positive control (group 2) (p<0.05). Based on statin administration, the percentage area of TNF-α staining was significantly reduced (p<0.05) in group 3, compared to the positive control group (group 2). However, significant differences were not observed for CD11b and CD163 staining. In group 4, no significant differences were observed for TNF-α, CD11b, and CD163 staining (p≥0.05). The differences in the percentage areas of the different markers between the statin-administered groups (groups 3 and 4) were also not revealed. Conclusion : We presented that statin administration before and after MT exerted protective effects towards vessel wall injury. The efficacy of statins was greater post-administration than pre-administration. Thus, statin administration in routine prescriptions in the peri-procedural period is strongly advised.

Analysis of the Disposal Rate of Fresh Frozen Femoral Head in the Bone Bank of a Single Hospital (단일 병원 인체조직은행에서 채취한 신선 동결 대퇴골두의 폐기율 분석)

  • Lee, Jaeyoung;Lee, Donghun;Jeon, Jinhwa;Lee, Kee Haeng
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.305-309
    • /
    • 2021
  • Purpose: This study analyzed the increase in disposal rate of femoral heads in the bone bank of a single hospital from medical disease and drug history, as assessed by the Korean health insurance review and assessment service. Materials and Methods: The disposal rate and cause of 340 femoral heads were analyzed according to the regulations of the bone bank based on the standard model of the Ministry of food and drug safety. Results: One hundred and seven (33%) of 323 femoral heads collected from 2009 to 2018, and 65 (46%) of 142 femoral heads collected from 2015 to 2018 were discarded. The most common causes were related to the history of dementia and the administration of radioisotope for nuclear medicine. Conclusion: The current methods and screening tools can lead to errors in disposing of the available tissues in a bone bank. Thus, improved standards and screening methods are needed.

A Study on Data Quality Evaluation of Administrative Information Dataset (행정정보데이터세트의 데이터 품질평가 연구)

  • Song, Chiho;Yim, Jinhee
    • The Korean Journal of Archival Studies
    • /
    • no.71
    • /
    • pp.237-272
    • /
    • 2022
  • In 2019, the pilot project to establish a record management system for administrative information datasets started in earnest under the leadership of the National Archives. Based on the results of the three-year project by 2021, the improved administrative information dataset management plan will be reflected in public records-related laws and guidelines. Through this, the administrative information dataset becomes the target of full-scale public record management. Although public records have been converted to electronic documents and even the datasets of administrative information systems have been included in full-scale public records management, research on the quality requirements of data itself as raw data constituting records is still lacking. If data quality is not guaranteed, all four properties of records will be threatened in the dataset, which is a structure of data and an aggregate of records. Moreover, if the reliability of the quality of the data of the administrative information system built by reflecting the various needs of the working departments of the institution without considering the standards of the standard records management system is insufficient, the reliability of the public records itself can not be secured. This study is based on the administrative information dataset management plan presented in the "Administrative Information Dataset Recorded Information Service and Utilization Model Study" conducted by the National Archives of Korea in 2021. A study was conducted. By referring to various data, especially public data-related policies and guides, which are being promoted across the government, we would like to derive quality evaluation requirements in terms of records management and present specific indicators. Through this, it is expected that it will be helpful for record management of administrative information dataset which will be in full swing in the future.

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

A study on the implementation of Medical Telemetry systems using wireless public data network (무선공중망을 이용한 의료 정보 데이터 원격 모니터링 시스템에 관한 연구)

  • 이택규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.278-283
    • /
    • 2000
  • As information communication technology developed we could check our blood pressure, pulsation electrocardiogram, SpO2 and blood test easily at home. To check our health at ordinary times is able though interlocking the house medical instrument with the wireless public data network This service will help the inconvenience to visit the hospital everytime and will save the individual's time and cost. In each house an organism data which is detected from the human body will be transmitted to the distance hospital and will be essentially applied through wireless public data network The medical information transmit system is utilized by wireless close range network It would transmit the obtained organism signal wirelessly from the personal device to the main center system in the hospital. Remote telemetry system is embodied by utilizing wireless media access protocol. The protocol is embodied by grafting CSMA/CA(Carrier Sense Multiple Access with Collision Avoidance) protocol falling mode which is standards from IEEE 802.11. Among the house care telemetry system which could measure blood pressure, pulsation, electrocardiogram, SpO2 the study embodies the ECC(electrocardiograph) measure part. It within the ECC function into the movable device and add 900㎒ band wireless public data interface. Then the aged, the patients even anyone in the house could obtain ECG and keep, record the data. It would be essential to control those who had a health-examination heart diseases or more complicated heart diseases and to observe the latent heart disease patient continuously. To embody the medical information transmit system which is based on wireless network. It would transmit the ECG data among the organism signal data which would be utilized by wireless network modem and NCL(Native Control Language) protocol to contact through wireless network Through the SCR(Standard Context Routing) protocol in the network it will be connected to the wired host computer. The computer will check the recorded individual information and the obtained ECC data then send the correspond examination to the movable device. The study suggests the medical transmit system model utilized by the wireless public data network.

  • PDF

A Study on the Nursing Performance of the Home Care Nurses in Seoul (서울지역 가정간호사의 업무수행능력 실태조사)

  • Suh, Moon-Ja;Park, Ho-Ran;Kang, Hyun-Sook;Kim, So-Sun;Shin, Kyung-Lim;Kim, Keun-Soon;Kim, Hae-Sook
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.46-58
    • /
    • 1999
  • The purpose of this research was to find out the state of the nursing performance of the home care nurses in Seoul in order to provide the data for the practical work guide. The data were collected from fifty home care nurses working in 22 institutions located in Seoul. The research tool used for this research was modified and tested by Song Jong-Rye(1999) which was originally modified the standard tool of American Nurses Association (1998) and was partly supplement and adjusted for this research. The reliability of this tool was Cronbach's $\alpha$=.0982. The collected data were statistically processed using SAS for t-test, ANOVA. $Scheff\'{e}$ test. Among the surveyees, 50% have been working as a home care nurse more than three years and 74.0% of them were married. And 52% have B.S degree with certification of home care nurse from the certification program for Home Care Nurses affiliated at nursing schools. Half of the home care nursing organizations were based on the general hospitals, and most(78%) of the responsible senior personnels of those organizations were nurses. The following results are drawn from this research. 1) The level of nursing performance by the task sectors General performance level of home care nurses was relatively high in grade of 3.06 from total 4.00. Among the task sectors. the ethical field scored the highest points, and the next were nursing intervention, professional training, and data gathering, and the research sector scored the lowest point. 2) The level of nursing performance by general features of home care nurses Statistically relevant correlation between performance according to the duration of working experience as a nurse(p=0.8951) and performance according to the duration of working as home care nurse(p=0.2263) did not emerge. Also, performance by marriage status(p=0.2218), education(p=0.5733), and taking the certification program for home card nurse(p =0.1560) has no statistically meaningful correlation. 3) The level of nursing performance by the type of home care nursing organizations There exists a significant difference(p=0.002) between performances by the types of organizations. Most of the responsible senior personnels of the home care nursing organization were nurses. The level of nursing performance of the home care nursing organization under nurse management was relatively higher than that of home care nursing organizations led by medical doctors or non-medical professional, but this was not proved as statistically meaningful(p =0.3617). 4) The level of nursing performance by task sectors according to the characteristic of home care nursing service organization There exists a significant difference between nursing performances by task sectors according to the characteristics of home care nursing organization(p=0.002). In case of model research center of one College of Nursing, the nursing performance in the sectors of organization, theory, and data gathering were lower than that of in hospital based home care nursing service. And in case of local home care centers, performances in sectors of organization, theory, data gathering, nursing intervention. professional training, and research sectors were significantly low. Based on the obtained results, overall performance of home care nurses can be appraised as relatively good. Especially, performances in sectors of the nursing intervention, nursing plan. and data gathering including the in direct nursing were recorded high scores. From this, it can be concluded that high quality of nursing is relatively practicing for home patients at these days. Since the high quality of nursing for patients was directly related to the level of nursing performances of home care nurses, it is required to improve practical performance level of them by making constant evaluation and running continual education program and supplementing curriculum for the sectors with low scores.

  • PDF

A Study on the Estimation Method of the Repair Rates in Finishing Materials of Domestic Office Buildings (국내 업무시설 건축 마감재의 수선율 산정 방안에 관한 연구)

  • Kim, Sun-Nam;Yoo, Hyun-Seok;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.52-63
    • /
    • 2015
  • Business facilities among domestic architectures have rapidly been constructed along with domestic economic development. It is an important facility taking the second largest proportion next to apartment buildings among current 31 building types of fire department classification of 2012 year for urban architectures. The expected service life of business facilities is 15 years, but 70% of those in urban areas have surpassed the 15 year service life as of the present 2014. Thus, the demand for urgent rehabilitation of such facilities is constantly increasing due to the aging and performance deterioration of the facilities'main finishing materials. Especially, the business facilities are being used for the lease of company office or private office, and such problems as aging and performance deterioration of the facilities could cause less competitive edge for leasing and real estate value depreciation for the O&M (Operation & Management) agent and the owner, respectively. Therefore, an effective planned rehabilitation as a preventive measure according to the standardized repair rate by the number of years after the construction is in need in order to prevent the aging and performance deterioration of the facilities(La et al. 2001). Nonetheless, domestic repair/rehabilitation standards based on the repair rate are mainly limited to apartment buildings and pubic institutions, resulting in impractical application of such standards to business facilities. It has been investigated and analyzed that annual repair rate data for each finishing material are required for examination of the applicability of the repair rate standard for the purpose of establishment of a repair plan. Hence, this study aimed at developing a repair rate computation model for finishing materials of the facilities and verifying the appropriateness of the annual repair rate for each finishing material through a case study after collecting and analyzing the repair history data of six business facilities. The results of this study are expected to contribute to the planning and implementation of more efficient repair/rehabilitation budget by preventing the waste of unpredicted repair cost and opportunity cost for the sake of the business facilities' owners and O&M agents.