• Title/Summary/Keyword: Standard sample

Search Result 2,196, Processing Time 0.033 seconds

A Study on the Nucleus System of Standard Hospitals in U.K. (영국의 표준병원에서 뉴클리우스 시스템에 대한 연구)

  • Moon, Chang-Ho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.3 no.4
    • /
    • pp.59-68
    • /
    • 1997
  • This study is intended to review the Nucleus System of standard hospitals in U.K. The research is focused on the theoretical background, contents of Nucleus System, and the operational problems through the survey of sample hospitals. The contents of research include the development history of standardization, outlines, aimes, advantages, the data of Nucleus system, and the study-visits of sample hospitals. The conclusion could be summarized as follows ; 1) The form of standard hospitals is compact and low-rise the major movements are horizontal. The standard plans of the functional dpartments are unified as cruciform with $15m{\times}15m$ module. 2) The Nulceus System has been developed. The hospitals have 3 stories maximum and courtyards for natural light & ventilation. 3) The advantages of Nucleus System includes reduction of design & construction period, the buildability due to the repetitive construction, and the running cost. And the disadvantages are mentioned as the lack of storage, staff accomodation, pantry, and sanitary facilities. 4) Sample hospitals provide human scale, possibilities of growth & change, and curing environment from art decoration & artificial lake. 5) In case of Korean situation, even the minimum standardization such as hospital design guidelines should be developed in near future.

  • PDF

Sample size estimation using nomogram in dental research (치의학 연구에서 노모그램을 이용한 표본수 계산)

  • Kim, Ki-Yeol
    • The Journal of the Korean dental association
    • /
    • v.54 no.8
    • /
    • pp.630-638
    • /
    • 2016
  • The appropriate sample size calculation in dental research is important to achieve the study purpose at the first step in study design. However, it cannot be easy to calculate sample size using standard formulas, because the several factors must be considered for calculation. This study introduced the graphic method for sample size calculation, which is called nomogram. The purpose of this study is to show the effectiveness of the nomogram using examples, expecting the researchers can easily use nomogram for sample size determination.

  • PDF

A Study on 7th Probability and Statistics Education In Mathematics 1 Textbooks in Korea (수학 I 검정교과서 확률통계 영역에 대한 연구)

  • Lee Sang Bock;Sohn Joong-Kweon;Chung Sung Suck
    • The Korean Journal of Applied Statistics
    • /
    • v.18 no.1
    • /
    • pp.197-210
    • /
    • 2005
  • In Korea, mathematics education has been taken according to the 7th national mathematics curriculum renovated by the Ministry of Education and Human Resources Development announcement in 1997. The education of probability and Statistics has been carried out as a part of this curriculum. We analyze and compare mathematics 1 textbooks for 11-12 grade students. Descriptions of random variable, sample variance and sample standard deviation, distribution of sample mean, and etc. which are on some textbooks, are misleaded in school education. We suggest the unbiased estimator of sample variance in accordance with textbooks and central limit theorem of sample mean under normal population.

Analysis of the Process Capability Index According to the Sample Size of Multi-Measurement (다측정 표본크기에 대한 공정능력지수 분석)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.1
    • /
    • pp.151-157
    • /
    • 2019
  • This study is about the process capability index (PCI). In this study, we introduce several indices including the index $C_{PR}$ and present the characteristics of the $C_{PR}$ as well as its validity. The difference between the other indices and the $C_{PR}$ is the way we use to estimate the standard deviation. Calculating the index, most indices use sample standard deviation while the index $C_{PR}$ uses range R. The sample standard deviation is generally a better estimator than the range R. But in the case of the panel process, the $C_{PR}$ has more consistency than the other indices at the point of non-conforming ratio which is an important term in quality control. The reason why the $C_{PR}$ using the range has better consistency is explained by introducing the concept of 'flatness ratio'. At least one million cells are present in one panel, so we can't inspect all of them. In estimating the PCI, it is necessary to consider the inspection cost together with the consistency. Even though we want smaller sample size at the point of inspection cost, the small sample size makes the PCI unreliable. There is 'trade off' between the inspection cost and the accuracy of the PCI. Therefore, we should obtain as large a sample size as possible under the allowed inspection cost. In order for $C_{PR}$ to be used throughout the industry, it is necessary to analyze the characteristics of the $C_{PR}$. Because the $C_{PR}$ is a kind of index including subgroup concept, the analysis should be done at the point of sample size of the subgroup. We present numerical analysis results of $C_{PR}$ by the data from the random number generating method. In this study, we also show the difference between the $C_{PR}$ using the range and the $C_P$ which is a representative index using the sample standard deviation. Regression analysis was used for the numerical analysis of the sample data. In addition, residual analysis and equal variance analysis was also conducted.

A Study on the Estimation of Convenient Sample Size for Cocoon Reeling Test (조사검정에 있어서의 적정시료량의 추정에 관한 연구)

  • 이인전
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.1
    • /
    • pp.27-30
    • /
    • 1973
  • The present research has been carried out in an attempt to obtain fundamental data which contribute to enhansing the accuracy of cocoon reeling test and improving the method of it more effectively. The results obtained are as follows: 1. The standard deviation and coefficient of variation of percentage of reelability and of percentage of raw silk yield to the sample size tended to show a gradual decrease according to the increasing of the sample size. However, the significant differences in the standard deviation and coefficient of variation of percentage of reelability and of percentage of raw silk yield between the different sizes of the samples having more than 300 cocoons have not been observed according to their sizes. 2. The significant difference in the standard errors from percentage of reelability between the samples of 300 cocoons and 400 cocoons have not been observed. 3. The significant difference in the standad errors from percentage of raw silk yield between the samples of 300 cocoons, 500 cocoons and 600 cocoons have not been observed. 4. The significant difference in the standard deviation, the standard errors and coefficient of variation to the length of a bave between the different sizes of the samples have not been shown. 5. From the above result, it is estimated that the optimum sire of the sample for the cocoon reeling test is the 300 cocoons.

  • PDF

A Study on the Knit Pattern Considering the Characteristics of Rib Stitch(2) -Focused on $2{\times}1\;and\;2{\times}2$ Rib Stitches (리브조직의 특성을 고려한 니트 패턴 연구(2) -$2{\times}1$ rib 조직과 $2{\times}2$ rib 조직을 중심으로-)

  • Kim, Soo-Ah;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.1
    • /
    • pp.47-59
    • /
    • 2005
  • This study aims to measure stretch rate of standard weight in the $2{\times}1$ rib stitch and $2{\times}2$ rib stitch, and to apply features of rib stitch to the knit pattern. The reviewer examined the sample knit for test with 100% wool, $2/48's{\times}2$, 12 gauge, and then made knit patterns and sample clothes for test considering stretch rate of standard weight of 10gf, 15gf, 20gf, 25gf based on the results from the former test, and finally estimated the try-outs for sample clothes. This study came out with the following results: From the functional estimate of knit patterns made by standard stretch rate of each stitch, the 20gf weight sample clothes of $2{\times}1$ and $2{\times}2$ rib stitchs were in high estimate. For the bust, B/4~ -4.6cm knit pattern was made of $2{\times}1$ rib stitch, B/4~5.3cm of $2{\times}2$ rib stitch. In conclusion, because $2{\times}1$ and $2{\times}2$ rib stitchs has the much higher stretch rate in the direction of the course than $0{\times}0$ ad $1{\times}1$ rib stitchs, high stretch rate of standard weight should be applied to the case of making knit wear. It is expected that this will lead stable sizing and measurement system when used in making knit patterns, and satisfy knit wearers' various needs.

  • PDF

A Study on the Knit Pattern Considering the Characteristics of Rib Stitch(1) - Focused on 0${\times}$0 and 1${\times}$1 Rib Stitches (리브조직의 특성을 고려한 니트 패턴 연구(1) -0${\times}$1 rib 조직과 1${\times}$1 rib 조직을 중심으로)

  • 김수아;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.5
    • /
    • pp.769-780
    • /
    • 2004
  • This study aims to measure stretch rate of standard weight in the direction of the knit stitch course by the difference in the way of weaving rib stitch, the most elastic stitch of all the knit stitches and to apply features of rib stitch to the knit pattern. The reviewer examined the sample knit for test with 100% wool, 2/48's 2, 12 gauge, and then made knit patterns and sample clothes for test considering stretch rate of standard weight of 10gf, l5gf, 20gf, 25gf based on the results from the former test, and finally estimated the try-outs for sample clothes. This study came out with the following results. From the functional estimate of knit patterns made by standard stretch rate of each stitch, the l5gf weight sample clothes of 0×0 and 1×1 rib stitches looking similar to plain stitch. For the bust, B/4-1.0㎝ knit pattern was made of 0×0 stitch, B/4-1.2㎝ of 1×1 rib stitch. In conclusion, because rib stitch has the much higher stretch rate in the direction of the course than other stitches, low stretch rate of standard weight should be applied to the case of making knit wear. It is expected that this will lead stable sizing and measurement system when used in making knit patterns, and satisfy knit wearers' various needs.

  • PDF

JOINT ASYMPTOTIC DISTRIBUTIONS OF SAMPLE AUTOCORRELATIONS FOR TIME SERIES OF MARTINGALE DIFFERENCES

  • Hwang, S.Y.;Baek, J.S.;Lim, K.E.
    • Journal of the Korean Statistical Society
    • /
    • v.35 no.4
    • /
    • pp.453-458
    • /
    • 2006
  • It is well known fact for the iid data that the limiting standard errors of sample autocorrelations are all unity for all time lags and they are asymptotically independent for different lags (Brockwell and Davis, 1991). It is also usual practice in time series modeling that this fact continues to be valid for white noise series which is a sequence of uncorrelated random variables. This paper contradicts this usual practice for white noise. We consider a sequence of martingale differences which belongs to white noise time series and derive exact joint asymptotic distributions of sample autocorrelations. Some implications of the result are illustrated for conditionally heteroscedastic time series.

Uncertainty of Total Alkaloids and Reducing Sugar Determination in Flue-cured Tobacco (황색종 담배중 전알카로이드와 환원당 분석에 대한 불확도 측정)

  • 백순옥;장기철;이운철;한상빈
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This study was carried out to evaluate the uncertainty in the analysis of total alkaloids and reducing sugar content in flue-cured tobacco. The sources of uncertainty associated with the analysis of total alkaloids and reducing sugar were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the preparation of standard solution, the precision of calibration curve for standard solution, the reproducibility of analysis, and the determination of water content in tobacco, etc. For the calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier’s catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the calibration curve of standard solution, the reproducibility of analysis, the volume measurement of 1$m\ell$, and the purity of nicotine reference material in the preparation of standard solution. The uncertainty in the addition of extracting solution, the sample weighing, the volume measurement of 100$m\ell$, and the determination of water content of tobacco contributed relatively little to the overall uncertainty. The expanded uncertainty of total alkaloids and reducing sugar in flue-cured tobacco at 95% level of confidence was $\pm$0.12% and $\pm$0.54%, respectively.

  • PDF

Determination of Bi Impurity in Lead Stock Standard Solutions by Hydride-generation Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.233-236
    • /
    • 2004
  • Total impurity analysis of a primary standard solution is one of the essential procedures to determine an accurate concentration of the standard solution by the gravimetry. Bi impurity is determined in Pb standard solutions by inductively coupled plasma mass spectrometry (ICP-MS). The direct nebulization of the Pb standard solution produces a significant amount of the Pb matrix-induced molecular ions which give rise to a serious spectral interference to the Bi determination. In order to avoid the spectral interference from the interferent $^{208}PbH^+$, the hydride generation method is employed for the matrix separation. The Bi hydride vapor is generated by reaction of the sample solution with 1% sodium borohydride solution. The vapor is then directed by argon carrier gas into the ICP after separation from the mixture solution in a liquid-gas separator made of a polytetrafluoroethylene membrane tube. The presence of 1000 ${\mu}$g/mL Pb matrix caused reduction of the bismuthine generation efficiency by about 40%. The standard addition method is used to overcome the chemical interference from the Pb matrix. Optimum conditions are investigated for the hydride-generation ICPMS. The detection limit of this method is 0.5 pg/mL for the sample solutions containing 1000 ${\mu}$g/mL Pb matrix.