• 제목/요약/키워드: Standard reference material

검색결과 239건 처리시간 0.025초

Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

  • Yim, Yong-Hyeon;Park, Ji-Youn;Han, Myung-Sub;Park, Mi-Kyung;Kim, Byung-Joo;Lim, Young-Ran;Hwang, Eui-Jin;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.440-446
    • /
    • 2005
  • A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교 (Comparison of Blood Lead Concentration Using Graphite Furnace Atomic Absorption Spectrometry (GF-AAs) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS))

  • 강민경;권정연;김병권;임현주;서정욱;김유미;홍영습
    • 한국환경보건학회지
    • /
    • 제45권3호
    • /
    • pp.258-266
    • /
    • 2019
  • Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GF-AAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ${\pm}40%$ of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.

BIM 기반 비정형 건축물 패널화 모델 생성 방법에 관한 연구 (BIM-Based Generation of Free-form Building Panelization Model)

  • 김양길;이윤구;함남혁;김재준
    • 한국BIM학회 논문집
    • /
    • 제12권4호
    • /
    • pp.19-31
    • /
    • 2022
  • With the development of 3D-based CAD (Computer Aided Design), attempts at freeform building design have expanded to small and medium-sized buildings in Korea. However, a standardized system for continuous utilization of shape data and BIM conversion process implemented with 3D-based NURBS is still immature. Without accurate review and management throughout the Freeform building project, interference between members occurs and the cost of the project increases. This is very detrimental to the project. To solve this problem, we proposed a continuous utilization process of 3D shape information based on BIM parameters. Our process includes algorithms such as Auto Split, Panel Optimization, Excel extraction based on shape information, BIM modeling through Adaptive Component, and BIM model utilization method using ID Code. The optimal cutting reference point was calculated and the optimal material specification was derived using the Panel Optimization algorithm. With the Adaptive Component design methodology, a BIM model conforming to the standard cross-section details and specifications was uniformly established. The automatic BIM conversion algorithm of shape data through Excel extraction created a BIM model without omission of data based on the optimized panel cutting reference point and cutting line. Finally, we analyzed how to use the BIM model built for automatic conversion. As a result of the analysis, in addition to the BIM utilization plan in the general construction stage such as visualization, interference review, quantity calculation, and construction simulation, an individual management plan for the unit panel was derived through ID data input. This study suggested an improvement process by linking the existing research on atypical panel optimization and the study of parameter-based BIM information management method. And it showed that it can solve the problems of existing Freeform building project.

실용적이고 최적화된 광물정량분석법 연구 (A Study of Practical and Optimized Mineral Quantification)

  • 손병국;안기오
    • 광물과 암석
    • /
    • 제34권4호
    • /
    • pp.227-239
    • /
    • 2021
  • 자연산 시료의 광물함량을 X-선 분말회절분석에 의하여 실용적이고 효과적으로 정량분석하는 방법에 대하여 연구하였다. 이를 위하여 무작위 배향된 분말시료 마운트(randomly oriented powder sample mount)를 최적으로 제작하는 실험을 하였으며, 단일 피크강도를 표준물질과 비교하여 정량분석하는 레퍼런스 강도비(RIR) 방법과 X-선 회절도의 전패턴을 계산하는 리트벨드 방법의 효율성을 비교하는 실험을 수행 하였다. 또한, 비정질 광물이 포함된 시료를 리트벨드 방법에 의하여 정량분석하고 효율성을 검토하였다. 연구결과, 측면 마운팅(side mounting) 방법에 의하여 최적의 무작위 배향(random orientation)에 도달할 수 있었다. 또한, 특정 피크를 사용하는 RIR방법보다는 X-선 회절도의 전패턴을 사용하는 리트벨드 방법이 정량분석에 더 적합하였다. 그러나 어느 방법이든 분석기술 뿐만 아니라 분석자의 숙련된 경험을 필요로 한다. 리트벨드 방법에 의해 비정질 광물도 정량분석할 수 있었으며 분석결과는 지질해석을 가능하게 하였다.

Cone-Beam CT에서 물질 및 호흡 변화가 영상에 미치는 영향에 대한 고찰 (Consideration of the Effect according to Variation of Material and Respiration in Cone-Beam CT)

  • 나준영;김정미;김대섭;강태영;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제24권1호
    • /
    • pp.15-21
    • /
    • 2012
  • 목 적: 본원에서 시행하고 있는 영상유도 방사선치료(Image Guided Radiation Therapy, IGRT)는 On-Board Imager system(OBI)을 이용하여 실시하고 있다. 본 논문에서는 Cone-Beam CT에서 물질 및 호흡의 변화가 영상에 미치는 영향을 분석하고 평가하고자 한다. 대상 및 방법: 호흡의 모양을 임의로 조정할 수 있는 구동 팬텀(Motion Phantom)을 이용하여 기준 호흡에 따른 주기, 진폭, 기저호흡(Baseline)을 변화시키면서 폐 등가 물질 내의 지름 3 cm인 구 형태의 아크릴(Acryl)과 임상에 이용되고 있는 표지자(Fiducial Marker) 두 물질에 대하여 Cone-Beam CT를 총 3회 획득하고, 분석하였다. 결 과: 첫 번째 물질의 종류에 따라 구동 팬텀의 동일한 움직임을 원형 아크릴(Arcyl)일 때 100%, 표지자일 때 120% 나타내었다. 두 번째 기준 호흡 변화에 따라 기준 호흡의 영상크기를 1로 상쇄(Offset)하면 원형 아크릴(Arcyl)의 경우 기저호흡(Baseline)을 1.8 mm 이동 시켰을 때 1.13, 3.3 mm 이동 시켰을 때 1.27, 주기가 1초일 때 1.01, 2.5초일 때 1.045, 진폭이 기준의 0.7배일 때 0.86, 1.7배일 때 1.43의 변화를 보였고, 표지자의 경우 Baseline 1.8 mm shift일 때 1.18, 3.3 mm shift일 때 1.34, 주기가 1초일 때 1.0, 2.5초일 때 1.0, 진폭이 기준의 0.7배일 때 0.99, 1.7배일 때 1.66의 변화를 보였다. 결 론: Cone-Beam CT는 물질에 따라 그 움직임을 나타내는 것에 Fiducial marker의 경우 영상 크기에 20%의 영향이 있었다. 호흡의 변화에 따른 영향은 아크릴(Arcyl)의 경우 최소 13% 최대 43%, Fiducial marker의 경우 최소 18% 최대 66%의 변화를 보였다. 이런 영상의 차이는 큰 불확실성 요인이므로 Cone-Beam CT 획득 전에 환자의 호흡을 안정화해야 한다. 또한 영상획득 중간에도 지속적인 환자의 호흡 관찰을 하여 환자의 큰 호흡변화를 관찰하였다면 영상유도 후에 반드시 투시를 이용하여 치료부위를 확인할 필요가 있으며 재 Cone-Beam CT 획득을 통하여 보다 정확한 영상유도를 하는 것이 바람직하다고 사료된다.

  • PDF

Ultra-trace Arsenic Determination in Urine and Whole Blood Samples by Flow Injection-Hydride Generation Atomic Absorption Spectrometry after Preconcentration and Speciation Based on Dispersive Liquid-Liquid Microextraction

  • Shirkhanloo, Hamid;Rouhollahi, Ahmad;Mousavi, Hassan Zavvar
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권11호
    • /
    • pp.3923-3927
    • /
    • 2011
  • A noble method for pre-concentration and speciation of ultra trace As (III) and As (V) in urine and whole blood samples based on dispersive liquid-liquid microextraction (DLLME) has been developed. In this method, As (III) was complexed with ammonium pyrrolidine dithiocarbamate at pH = 4 and Then, As (III) was extracted into the ionic liquid (IL). Finally, As (III) was back-extracted from the IL with hydrochloric acid (HCl) and its concentration was determined by flow injection coupled with hydride generation atomic absorption spectrometry (FI-HGAAS). Total amount of arsenic was determined by reducing As (V) to As (III) with potassium iodide (KI) and ascorbic acid in HCl solution and then, As (V) was calculated by the subtracting the total arsenic and As (III) content. Under the optimum conditions, for 5-15 mL of blood and urine samples, the detection limit ($3{\sigma}$) and linear range were achieved 5 ng $L^{-1}$ and 0.02-10 ${\mu}g\;L^{-1}$, respectively. The method was applied successfully to the speciation and determination of As (III) and As (V) in biological samples of multiple sclerosis patients with suitable precision results (RSD < 5%). Validation of the methodology was performed by the standard reference material (CRM).

실적자료를 활용한 PRICE 모델의 보정방안 연구 (A Study on Calibration of PRICE Model Using Historical Cost Data)

  • 정태균;이용복;강성진
    • 한국국방경영분석학회지
    • /
    • 제36권1호
    • /
    • pp.29-38
    • /
    • 2010
  • In Korea weapon system acquisition processes, it's required a cost estimation report obtained from a commercial cost model. The PRICE model is generally used as a cost estimation model in Korea. However, the model uses American historical R&D data and it's output cost component is different from our cost component of defense accounting system. Also, we found that estimating results show about 10% of difference when we comparing with actual costs in 44 finished weapon acquisition projects. There are some limitations in calibration to increase an accuracy of the PRICE model because it's difficult obtain good real input data, detailed cost and technical data in low level WBS. So, only 8% of the defense R&D projects are calibrated and validation of calibration results is more difficult. Therefore, we studied the standard calibration process and performed the calibration about the MCPLXS/E parameters of the PRICE model based on actual cost data. In order to obtain a good calculation result, we collected the actual material costs from the defense industry companies. Our results can be used for an reference in similar weapon system R&D and production cost estimation cases.

조명 설계 시스템을 위한 데이터베이스 개발에 관한 연구 (A Study on the Development of Database for Lighting Design System)

  • 조성오
    • 한국실내디자인학회논문집
    • /
    • 제13권4호
    • /
    • pp.196-203
    • /
    • 2004
  • In The Lighting design is important to acknowledge appearance space. Development of artificial light makes a extension to life space in the Modern life. With the rapid development of efficient light sources, have lighting design acquired the tools that allow artificial lighting to be produced with adequate illuminance levels. However, by the task of defining the objectives and methods behind discipline, of deciding on the criteria by which the artificial lighting that is now provide many available data to be anpaied. The main concern is which illuminace levels and types of lighting will ensure optimum visual performance, high productive and safety at design which are affordable. This study is support to standard design process with material reflection rate, installing the lighting fixture, task illuminance level and automatic arithmetic calculation during the lighting design. Lighting Design database can check and support other final lighting level. A quantitative light that is primarily oriented toward providing a recommended illuminance level, the criterion of develop a concept that goes beyond the requirements that would ensure productivity and safety to meet the needs of the architecture and interior space. illuminance level is compose to space task and space code according to KS A 3011. To be able to design the visual effect of an environment the central reference quantity has to provided the Database.

Reduction of Variable Illumination Effect on Pixel Gray-levels of Machine Vision

  • Suh S. R.;Huang J. K.;Kim Y. T.;Yoo S. N.;Choi Y. S.;Sung J. H.
    • Agricultural and Biosystems Engineering
    • /
    • 제5권1호
    • /
    • pp.5-9
    • /
    • 2004
  • This study was carried out to develop methods of reducing the effect of solar illumination on pixel gray-levels of machine vision for agricultural field use. Two kinds of monochrome CCD cameras with manual and auto-iris lenses were used to take pictures within a range of 15 to 120 klux of solar illumination. A camera having more precise automatic control functions gave much better result. Four kinds of indices using pixel gray-level of the $99\%$ white DRS (diffuse reflectance standard) as a reference were tried to compensate pixel gray-levels of an image for variable illumination. Coefficients of variation of the indices within a range of illumination were used as a criterion for comparison. The study concluded that an index of (A+B)/A, where A is gray-level of the $99\%$ DRS and B is gray-level of the tested material, gave the best consistency in the range of solar illumination.

  • PDF

Development of simple HPLC-UV method for discrimination of Adenophorae Radix

  • Vu, Thi Phuong Duyen;Kim, Kyung Tae;Pham, Yen;Bao, Haiying;Kang, Jong Seong
    • 분석과학
    • /
    • 제30권2호
    • /
    • pp.82-88
    • /
    • 2017
  • Adenophorae Radix (AR) is a frequently used medicinal herb; because of its popularity, products containing similar herbal products are often sold as substitutes, especially if their morphology is similar. However, any analytical method to identify AR based on quantitative analysis is not registered in Korea, Japan and China Pharmacopoeias. This study developed a simple HPLC method to discriminate between authentic AR and substitutes. Linoleic acid was used as a marker compound of AR. Our optimized HPLC-UV conditions included a mobile phase of 90 % acetonitrile under isocratic condition, and a flow rate of 1.0 mL/min at room temperature. Detection wavelength was set at 205 nm. Linoleic acid was detected at 13.5 minutes for a total analysis time of 20 minutes. The standard herb of AR contained 0.025 % of linoleic acid, while four authentic AR samples and eight substitutes contained 0.040~0.071 % and 0.004~0.014 %, respectively. Comparison of the linoleic acid concentrations of the sample types to reference AR showed that among 12 samples, only the four samples were authentic. Thus, our HPLC-UV method, along with our suggested content criterion for linoleic acid concentration, can be used for the quick and accurate determination whether the herbal products are authentic AR or substitute.