• Title/Summary/Keyword: Standard operating system

Search Result 670, Processing Time 0.029 seconds

Numerical Analysis on the Thermal Flow by a Thermoelectric Module within the Cabin of a Commercial Vehicle (상용차 캐빈 내의 열전모듈에 의한 열유동 수치해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.47-54
    • /
    • 2012
  • The steady three-dimensional numerical analysis on the thermal flow using standard k-${\varepsilon}$ turbulence model was carried out to investigate the air cooling effect of a cooler on the cabin for a commercial vehicle. Here, the heat exchanging method of this cabin cooler uses the cooling effect of a thermoelectric module. In consequence, the air system resistance of a cooler within the cabin is about 12.1 Pa as a static pressure, and then the operating point of a virtual cross-flow fan considering in this study is formed in the comparatively low flowrate region. The discharging air temperature of a cooler is about $14{\sim}15^{\circ}C$. Moreover, the air cooling temperature difference obtained under the outdoor cabin temperature of $40^{\circ}C$ shows about $7{\sim}9^{\circ}C$ in a driver resting space and about $9{\sim}14^{\circ}C$ in the front of a driver's seat including the space of a driver's foot.

H_{\infty} Control Synthesis for Power System Design using LMI Optimization Method (LMI 최적화기법을 적용한 $H_{\infty}$제어 시스템의 전력계통 안정화장치(PSS) 설계)

  • Jeong, Dae-Won;Ju, Un-Pyo;Kim, Geon-Jung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.4
    • /
    • pp.165-174
    • /
    • 2000
  • This paper presents the application of H$\infty$ control synthesis using LMI optimization method to power system stabilizer(PSS) design. Since power system is usually operated under circumstance of unmeasurable uncertainties and external disturbances, the improvement of small signal stability becomes one of the most important issue for securing system stability and preventing low frequency oscillation phenomena. The LMI optimized H$\infty$ PSS provides robust performance and guarantees the internal stability under these operating conditions. The global optimal H$\infty$ norm is found using LMI convex optimization method which is more systematic than standard two Riccati solution method. The design results are simulated for a case study. We verified that the LMI method shows the best performance characteristic smong standard Riccati method and conventional lead/lag method.

  • PDF

A Study on the Optimal Selection of Lightning Arresters for DC Electric Traction Vehicles (직류전동차 탑재용 피뢰기의 최적선정에 관한 연구)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Song, Jae-Yong;Kim, Il-Kwon;Park, Dae-Won;Han, Moon-Sup
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.112-116
    • /
    • 2007
  • In this paper, we proposed a selection and application recommendations of ZnO arresters for DC electric traction vehicles. To decide the Continuous Operating Voltage($U_C$), the Rated Voltage($U_r$), and the Nominal Discharge Current(In), we measured and analyzed system voltages and surge currents flowing the arrester installed on a DC electric traction vehicle under running state. System voltages measured up to 1,800 V in 1,500 V-system, and surge currents were recorded up to 3 times per a running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From these results and a standard EN50163, we could proposed $U_C$, $U_r$, and In available for the 1,500 VDC electric traction vehicles.

A Transformation from POSIX Based Source Code to OSEK/VDX Source Code Based on API and OIL Translation (API 및 OIL 변환을 이용한 POSIX 기반 코드의 OSEK/VDX 코드로의 변환)

  • Song, Young-Ho;Lee, Tae-Yang;Lee, Jong-Deok;Moon, Chan-Woo;Jeong, Gu-Min;Ahn, Hyun-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.6
    • /
    • pp.559-565
    • /
    • 2010
  • In this paper, we present a transformation method of source code from a POSIX (Portable Operating System Interface) based source code into an OSEK/VDX (Offene Systeme und deren Schnittstellen fur die Elektronik in Kraftfahrzeugen/Vehicle Distributed eXecutive) source code. As the electronic parts of automobile systems increase, the use of embedded software in automobile systems is also growing. Accordingly, many electronic systems are designed in automobile system with OSEK/VDX. Otherwise, one of the major problems of embedded software would be portability to other OS's. To enhance the portability and interoperability of embedded software, we propose a source code transformation method from POSIX to OSEK/VDX based on API (Application Programming Interface) translation method. Considering the characteristics of the OSEK/VDX which uses OIL (OSEK/VDX Implementation Language) standard, transformation process is performed with source code transformation and OIL code generation. For the validity of the proposed method, the transformation experiment is given using Micro-C OS II and OSEK/VDX with XC167CI micro-controller.

Investigation on the DeNOx Efficiency in Urea-SCR System at Various Operating Conditions and Injection Characteristics for a Passenger Diesel Engine (승용디젤엔진의 운전 조건 및 분사 조건 변경에 따른 Urea-SCR 시스템의 NOx 전환효율에 관한 연구)

  • Hong, Kil-Hwa;Hwang, In-Goo;Myung, Cha-Lee;Park, Sim-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.12
    • /
    • pp.952-960
    • /
    • 2009
  • Selective Catalytic Reduction (SCR) system is a high-effective NOx reduction technology in diesel engines. As the emission standard of diesel engines is more stringent, vehicle manufactures makes efforts on emission technologies. This paper discusses the performance of Urea-SCR system according to the engine operating conditions in a passenger diesel engine. Engine test results in this paper show that it is important to consider the catalyst temperature and space velocity to obtain high NOx conversion efficiency. In condition of high catalyst temperature, over 90% NOx conversion efficiency is indicated. However, when catalyst temperature is low, NOx conversion efficiency was decreased. Also, it was shown that space velocity mainly effects on the DeNOx performance under 220 degree celsius of SCR catalyst temperature. As the urea injection pressure was decreased, NOx conversion efficiency was declined. It is concerned about urea droplet atomization. This work shown in this paper can lead to improved overall NOx conversion efficiency.

Determining priorities for evaluation accreditation to assess dental hygiene education programs (치위생교육인증평가를 위한 평가인증 우선순위 결정)

  • Kim, Chang-Hee;Seong, Mi-Gyung;Lee, Sun-Mi
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.5
    • /
    • pp.643-652
    • /
    • 2018
  • Objectives: The purpose of this study was to review the systems used to evaluate dental hygiene education and to establish priorities for the evaluation index for accreditation to enhance competitiveness and facilitate quality control of dental hygiene education. Methods: A survey of priorities for accreditation evaluation was developed based on input from professors at 43 universities. Data were analyzed using the Analytic Hierarchy Process method with Expert Choice 2000 software. Results: The relative importance of each evaluation area, ranked in descending order, was as follows: vision and operating system; administration and finances; facilities and equipment; educational outcomes; professors; educational process; and students. The importance of the evaluation part was highest in field training at the education process part and scholarship at the student part. The importance after applying complex weights was highest in establishing a development plan for the vision and operating system. Conclusions: Practical accreditation evaluation based on objectivity and validity is needed to control the quality of dental hygiene education. Therefore, priorities in accreditation evaluation standard must be determined to establish a basis for quality improvement in education at dental hygiene departments.

A Study on the Long-term Operating plan of Ventilation System of Apartment House in terms of Energy Performance (공동주택 강제 환기 시스템의 건물에너지 측면에서의 장기적 운영 방안에 관한 연구)

  • Kim, Seung-Chul;Yoon, Jong-Ho;Baek, Nam-Choon;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.115-123
    • /
    • 2011
  • Because buildings recently built have been highly insulated and highly airtight, it is impossible to emit toxic substances from interior finishing materials only by natural ventilation. Therefore, they cause indoor air pollution and it may threaten the user"s health such as atopic dermatitis, bronchial asthma and (allergic) rhinitis. Domestically, users spend indoors 80 percent of their time of a day. With the increased interest in indoor air quality, the introduction of forced ventilation system for new-built apartment buildings has been legislated. However, toxic substances from indoor are mostly below there commended standard approximately 23 months later. Thus, this study has assumed the status of the apartment buildings 23 months later through a simulation, regarded $CO_2$ as an exclusive indoor air pollution source. In the process of effectively eliminating the $CO_2$, this study has also been conducted on an operating plan that can provide superior performance from the energy side.

  • PDF

A Study on the Best Selection of Lightning Arrester for DC Electric Traction Vehicles (직류전동차 탑재용 피뢰기의 최적선정에 관한 연구)

  • Cha, Myung-Soo;Song, Jae-Yong;Kim, Il-Kwon;Kil, Gyung-Suk;Lee, Dae-Sung;Park, Jae-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1519-1520
    • /
    • 2006
  • This paper describes a selection and application recommendations of ZnO arresters on DC electric traction vehicles. We measured and analyzed the system voltages applied to arresters and the surge currents flowing arresters on DC electric traction vehicles under operation to decide the Continuous Operating Voltage($U_C$), the Rated Voltage($U_R$), and the Nominal Discharge Current($I_n$). System voltages measured up to 1,800 V during anti-breaking in 1,500 V-system, and surge currents were recorded up to 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From these results and the standard EN50163, we proposed the Continuous Operating Voltage($U_C$) the Rated Voltage($U_R$) for the $1,500V_{dc}$ electric traction vehicles.

  • PDF

Performance Variations of Vaned Diffusers with Solidity and Exit Vane Angle (베인 디퓨저의 솔리디티와 출구 유동각에 따른 성능변화)

  • Cho, S.K.;Kang, S.H.;Cha, B.J.;Lee, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.422-427
    • /
    • 2000
  • The design of low-solidity vaned diffusers and the effect on the performance of a turbocharger compressor is discussed. The effect of vane number and turning angle was investigated while maintaining a basic design with a leading edge angle of $70^{\circ}$, leading and trailing edge radius ratios of 1.1 and 1.3. All results are compared with those obtained with the standard vaneless diffuser configuration and it was shown that all designs increased and shifted the pressure ratio to reduced flowrates. Despite the low-solidity configuration none of the vane designs provided a broad operating range, and the vane leading edge angle was not main factor that system went into the surge condition. The diffuser of higher trailing edge angle improved the flow range for the compressor to operate at lower flow region.

  • PDF

Reliability Assessment Criteria of Motorized Roller Conveyor (자체구동롤러 컨베이어의 신뢰성 평가기준)

  • Kim, Young-Joo;Go, Hee-Yang;Han, In-Sup;Kim, Yong Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.521-529
    • /
    • 2015
  • Owing to a reliance on imported products from Europe and Japan, the use of logistics equipment with poor energy efficiency coupled with high maintenance costs can lead to high operating costs for some domestic logistic centers. To lower their operating costs, the logistic centers use motorized roller conveyors. In order to commercialize this process, it is necessary to establish the test criteria and assess the reliability of the process. Currently, there exists no standard verification method to test the reliability of motorized roller conveyors. In this study, we propose reliability assessment criteria for a: i) reliability test, ii) environmental test, iii) safety test, and iv) lifetime test.