• Title/Summary/Keyword: Standard fire test

Search Result 294, Processing Time 0.027 seconds

A Novel Design of the Intelligent Fire Alarm Signaling System for the Integration of BAS by Developing Intelligent Control Modules with LonTalk Protocol of ANSI/EIA 709.1 (ANSI/EIA 709.1을 사용하는 지능형 제어모듈개발을 통한 화재 경보시스템의 새로운 설계방안)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.64-73
    • /
    • 2003
  • There are many economic and operational reasons to integrate fire alarm signaling system with other building automation system Integration of this requires open network with the standard communication protocol and careful design practices. The important point for this is also the development of intelligent control modules for replacing the conventional zone adapter in fire system. Therefore, this paper proposes an new conceptual design of the open distributed fire alarm signaling system for the integration of BAS and a new intelligent control modules with LonTalk protocol. Newly proposed additions to LonWorks network make it very well suited for integrating fire systems with other building automation systems. Additionally, it is very important that best design practices, test procedures and building codes need to be modernized to accommodate integrated building systems.

Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station (소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성)

  • Kim, Soo Jin;Ham, Seunghon;Jeon, Jeong Seok;Kim, Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.140-151
    • /
    • 2019
  • It is to assess the indoor air quality of the chemical hazardous materials exposed to the fire after firefighters returned to the fire scene. The research subject randomly selected four fire stations located in Seoul, Korea. Two fire stations were set up as control groups after the return of the firefighting activities at the actual fire scene, and two other fire stations were set up as control groups to measure the air quality of the room at normal levels regardless of the action. We conducted 24-hour monitoring for all fire accidents that occurred in Seoul Metropolitan using fire safety map computer system. Also, indoor air quality was measured immediately after homecoming if the experiment group was to be dispatched due to an accident of intermediate or larger scale. 11 hazardous substance items such as fine dust, formaldehyde, volatile organic compounds, PAH, VCM, acidity, asbestos, CO2, NO2, O3 were measured according to the process test method. Three of 11 types of harmful substances exceeded domestic and foreign standards, and one of them was found to be close to foreign standards. In particular, total volatile organic compounds, carbon dioxide and sulfuric acids were 2.5 times, 2.2 times and 1.1 times higher than the standard. Also, for formaldehyde and sulfuric acid, it was measured higher in the control group than in the case group. This findings could be used in policies to improve indoor air quality in the fire station of the Seoul Metropolitan Government.

A Research on Thermal Properties & Fire Resistance of A Water Film Covered Glazing System for Large Atrium Space (대규모 아트리움에 적용되는 수박형성 유리벽의 열적 특성 및 내화성능에 관한 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.38-55
    • /
    • 1999
  • In order practically to use fire-defective glazing materials for the compartment wall where a fire-protection rating is mandated, there have been many trials internationally, This research focuses on a feasibility that, if certain water film covered all surface of glass, the glazing system can endure without breaking out under the compartment fire. First of all, a water film spray system was specially designed to wet the entire surface of the glass and also to have tiny small amount of water rebounded from the surface after emitted from nozzles. After this system has proven to have perfect performance, small-scale tests were done to find out if the water film covered glazing system react to the high temperature curve in a small furnace room. Finally, on basis of the obtained data, full-scale experiments were done so that water-film covered glazing system can pass the Korean Standard (KS) test for fire resistance, KS F2257.

  • PDF

Experimental Capacity of Suspended Piping Trapeze Restraint Installations under Cyclic Loadings (반복하중을 받는 경량 배관 서포트 시스템에 대한 실험적 성능 평가)

  • Jeong, Sang-Deock;Oh, Chang-Soo;Park, Min Jae;Lee, Chang-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.3
    • /
    • pp.79-86
    • /
    • 2023
  • Damage to gas and fire protection piping systems can lead to secondary disasters after an earthquake, so their seismic design is crucial. Accordingly, various types of seismic restraint installations are being devised, and a new suspended piping trapeze restraint installation has also recently been developed in Korea. In this study, a cyclic loading test was performed on the developed trapeze support system, and its performance was evaluated according to ASHRAE 171, the standard for seismic and wind restraint design established by the American Society of Refrigeration and Air Conditioning Engineers (ASHRAE). The three support system specimens did not break or fracture, causing only insignificant deformations until the end of the experiment. Based on the experimentally rated strength and displacement performance, this trapeze support system is expected to control the seismic movement of piping during an earthquake.

Effects of the Treated Chemicals on the Flexual and Physical Properties of Fire Retardant Treated Particleboards (내화처리(耐火處理) 파티클 보오드의 휨강도(强度)와 물리적(物理的) 성질(性質)에 미치는 약제(藥劑)의 영향(影響))

  • Lee, Phil-Woo;Kwon, Jin-Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.39-48
    • /
    • 1983
  • This research was performed to investigate the manufacturing possibility of the particleboard treated with commercial fire retardant chemicals. Laboratory test boards at this investigation were made from particles treated by soaking into 5, 10, 15, and 20 percent concentration solutions of ammonium sulfate and Minalith before resin was applied. According to the results, MOR (modulus of repture) and MOE (modulus of elasticity) in flexure exceeded type 100 (100 kgf/$cm^2$, $1.5{\times}10^4\;kgf/cm^2$) of the Korean Industrial Standard (KS F 3104). Except for 15 and 20 percent chemicals concentrations of Minalith, every internal bond stress values met type 100 (1.5 kgf/$cm^2$) of KS F 3104. However thickness swelling values of fire retardant treated particleboards were not reached in the Standard (12%).

  • PDF

Effects of Characteristic Length Variation for Thrust Chamber on the Hot-fire Performance of Hydrazine Thruster (하이드라진 추력기의 추력실 특성길이 변화가 연소성능에 미치는 영향)

  • Kim, Jong Hyun;Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.2
    • /
    • pp.144-149
    • /
    • 2014
  • A ground firing test for hot-fire performance evaluation according to the characteristic length($L^*$) variation of thrust chamber was carried out for the hydrazine thruster which may be employed in space launch vehicles. A scrutiny into the performance characteristics of each thruster is made in terms of thrust, specific impulse, response characteristics, and characteristic velocity at steady-state firing mode with propellant inlet pressure of 2.41 MPa (350 psia). Through the test results, it has been verified that performance of characteristic velocity and specific impulse degrades as the characteristic length deviates from that of the standard model. Thus, it is confirmed that the thrust chamber configuration of standard model was suitably designed for the requirement specified.

An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire (화재시 하중재하에 따른 콘크리트의 열적특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Jung, Jae-Young;Kwan, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.66-74
    • /
    • 2009
  • When a fire occurs, the concrete structure's strength decreases by the increasing temperature under the fire in certain condition of constant load. And, the ratio of the axial force is changed by such decreased strength so that the structure is deformed. In this research, considering such case, we have conducted an actual fire test for the concrete lining with constant loading condition and various fire conditions. The specimen adopts the shape condition for small practical specimen defined by the EFNARC and we used 24MPa, 40MPa and 50MPa to analyze the thermal properties by the strength. The ratio of loading is imposed by a certain loading condition based on 20% and 40% of the sectional stress in concrete and MHC Fire is selected to realize the thermal impact of the concrete by rapid increasing temperature. As the result of the experiment, in the same ratio of loading, the 50MPa specimen shows more cracks and spalling as time goes on. The area damaged by the fire, according to the functional criteria of the concrete lining under the fire in ITA, does not satisfy with the standard in lack of 50mm depth from the heating surface at total 200mm lining.

The Level of Awareness and Practice in Prehospital Emergency Patient Assessment and Emergency Care of Paramedic in Fire Station (1급 응급구조사의 병원 전 응급환자평가와 응급처치시행에 대한 인식과 실천정도)

  • Kang, Yong-Ju;Choi, En-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.2
    • /
    • pp.67-84
    • /
    • 2011
  • Purpose: The aim of this study is to present the basic data for qualitative improvement of emergency care for emergency patient by paramedic in fire station by understanding the level of awareness and practice in prehospital and transfer step, and understanding the level of emergency care and improvement of clinical knowledge through hospital clinical training. Methods: The researchers explained the objective for 143 persons who completed hospital clinical training from June 2nd, 2006 to October 23rd, 2009 among paramedic in fire station. The questionnaire in this research consisted of 80 questions. In the reliability for the awareness of emergency patient assessment, cronbach's $\alpha$ was 0.95, and in the reliability for emergency care fulfillment, cronbach's $\alpha$ was 0.93. reliability for clinical knowledge improvement is cronbach's $\alpha=.95$, and reliability for emergency care fulfillment is cronbach's $\alpha=.82$. Collected data was analyzed through SPSS 18.0 statistics program for frequency, percentage, average, standard deviation, Paired t-test, t-test, Correlation Coefficient, and internal consistency reliability was analyzed by cronbach's $\alpha$. Results: 1) The paramedic awareness and practice difference for emergency patient is statistically signification for general patient assessment(t=14.159, p=.000), trauma patient assessment(t=11.288, p=.000), internal medicine patient assessment(t=10.898, p=.000), and it shows the level of practice is lower than the level of awareness. 2) The paramedic difference between the level of awareness and practice according to whether or not they have clinical career is not signification on awareness(t=3.119, p=.125), and is high on practice(t=3.119, p=.002). 3) The correlation between paramedic awareness and the level of practice shows positive correlation(r=.61, p=.000). The higher the awareness of emergency patient assessment is, the higher the level of practice is. 4) The difference between paramedic clinical knowledge improvement and the level of emergency care practice is statistically significant(t=3.351, p=.001). 5) 89.6%(128 persons) of paramedic replied hospital clinical training experiences are helpful for field activity. 92.3%(133 persons) replied they apply well for clinical knowledge learned during hospital clinical training and emergency care skills in the field. Conclusion: Paramedic in fire station must evaluate the patient's initial assessment and activate the transfer system to the emergency department. It is necessary to develop and implement the effective education program continuously. The education program should systemize currently operated hospital clinical training. emergency disease and symptoms emergency care method, and practice mainly skill education should be progressed. In the prehospital and transfer management, high quality of medical assessment is required to the emergency medical service system. Medical direction from the doctors can feedback the paramedic continuously and continuing education must be provided to the paramedic in fire station.

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.

Fire resistance assessment of precast fireproof duct slab (프리캐스트 방식 내화풍도슬래브의 화재저항성 평가)

  • Choi, Soon-Wook;Kang, Tae-Ho;Lee, Chulho;Kim, Se Kwon;Kim, Tae Kyun;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.6
    • /
    • pp.669-680
    • /
    • 2020
  • In Korea, fireproof performance is evaluated through a series of fire-resistance tests for important structures, and the performance standard follows the guidelines suggested by ITA. The fireproof duct slab manufactured by combining the slab and the fireproof material with a precast method is effective in that it can eliminate the construction time of the fireproof material. In this study, a series of fire resistance tests was performed on the fire test specimens under the RWS fire scenario in order to secure the fire resistance performance of the precast fireproof duct slab. As a result of the test, it was found that the fireproof performance was secured when the thickness of the fireproof material was 30 mm or more. In both fireproof materials and concrete, the rate of temperature change initially increased, then decreased, and then increased again, and the temperature at the inflection point was measured as 110℃ for all fireproof materials and concrete. It is judged that this occurs when the C-S-H (CaO-SiO2-H2O) generated by the hydration reaction in both the fireproof material and concrete is dehydrated.