• Title/Summary/Keyword: Standard error

Search Result 2,472, Processing Time 0.03 seconds

Development of Intelligent Robot Vision System for Automatic Inspection of Optical Lens (광학렌즈 자동 검사용 지능형 로봇 비젼 시스템 개발)

  • 정동연;장영희;차보남;한성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.247-252
    • /
    • 2004
  • Developed shape awareness technology and vision technology for optical ten slant in this research and including external form state of lens for the performance verification developed so that can be good achieve badness finding. And, establish to existing reflex data because inputting surface badness degree of scratch's standard specification condition directly, and error designed to distinguish from product more than schedule error to badness product by normalcy product within schedule extent after calculate the error comparing actuality measurement reflex data md standard reflex data mutually. Developed system to smallest 1pixel unit though measuring is possible 1pixel as 3.7$\mu\textrm{m}$${\times}$3.7$\mu\textrm{m}$(0.1369${\times}$10/sub-1/$\textrm{mm}^2$) the accuracy to 10/sub-1/mm minutely measuring is possible performance verification and trust ability through an experiment prove.

  • PDF

Output Behavior of Build-Up Force Measuring System (BUILD-UP 힘측정 시스템의 출력거동)

  • 강대임;송후근;홍창선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2194-2205
    • /
    • 1995
  • In order to reduce the systematic error of a build-up system, we have proposed a new test procedure in which all force transducers in a build-up system are rotated by 90.deg. with a base platen fixed on a force standard machine. The setting positions of force transducers on the output of a build-up system were investigated using an orthogonal array. The effects of the parallelism of a build-up system and of the bending moment sensitivity of a force transducer were considered. The experimental results show that the setting position of the base platen hardly affects the output of the build-up system, but the setting positions of force transducers affects it strongly. It reveals that the new test procedure reduces effectively the systematic error of a build-up system.

Signal-to-Noise Ratio Formulas of a Scalar Gaussian Quantizer Mismatched to a Laplacian Source

  • Rhee, Ja-Gan;Na, Sang-Sin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6C
    • /
    • pp.384-390
    • /
    • 2011
  • The paper derives formulas for the mean-squared error distortion and resulting signal-to-noise (SNR) ratio of a fixed-rate scalar quantizer designed optimally in the minimum mean-squared error sense for a Gaussian density with the standard deviation ${\sigma}_q$ when it is mismatched to a Laplacian density with the standard deviation ${\sigma}_q$. The SNR formulas, based on the key parameter and Bennett's integral, are found accurate for a wide range of $p\({\equiv}\frac{\sigma_p}{\sigma_q}\){\geqq}0.25$. Also an upper bound to the SNR is derived, which becomes tighter with increasing rate R and indicates that the SNR behaves asymptotically as $\frac{20\sqrt{3{\ln}2}}{{\rho}{\ln}10}\;{\sqrt{R}}$ dB.

An Identification Method of the Influence of Flow Conditions on the Flow Metering Error (유량측정 오차에 미치는 유동조건의 영 향 검출방법 연구)

  • Lee, K.B.;Choi, H.M.;Paik, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.34-41
    • /
    • 1991
  • The effect of flow conditions on flow measurement is difficult to identify from the inherent characteristics of the flowmeters and flow standard system. A new experimental approach has been attempted to detect the turbine meter error due to inlet flow conditions. In this try not only the design of the turbine meter package but also the data analysis method was altered. It was found that k factor slope of the turbine meter responds to the change of flow conditions in the test line with higher sensitivity than the degree of the data scattering. The flow standard system of $0.1m^3/s$ was chosen for the investigation. The systematic and random error of the system were less than ${\pm}0.08%$ and ${\pm}0.13%$ respectively.

  • PDF

An Error Sensitivity Analysis of Tape Traveling Path due to Geometric Variations of Tape Transport Elements of VHS VTR (VHS 방식 VTR 주행계 요소의 기하학적 배치 변동에 따른 주행경로의 오차민감도 해석)

  • 최진호;최동훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2655-2663
    • /
    • 1993
  • In order to evaluate the relative significance of tolerance management of various elements in a VHS VTR tape transport system, the effect of geometric variations of the elements from standard design values on the tape traveling path is studied. The tape is modeled as a string and each element in the tape transport system is modeled as a cylinder whose radius, position vector and orientation vector are specified. An numerical algorithm is proposed to find the coordinates of tape entry points and tape exit points for the elements from which the tape traveling path can be completely described. By using the suggested algorithm, an error sensitivity analysis of tape traveling path due to the geometric variations of tape transport elements is performed for a particular model in the market and the elements demanding relatively strict tolerance management are identified.

Creep-Life Prediction and Standard Error Analysis of Type 316LN Stainless Steel (Type 316LN 스테인리스 강의 크리프 수명 예측과 표준오차 분석)

  • Yun S.N.;Kim W.G.;Liu W.S.;Yi W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1406-1411
    • /
    • 2005
  • The creep rupture data for type 316LN stainless steels were collected through literature survey or experimental data produced in KAERI. Using these data, polynomial equations for predicting creep life were obtained by Larson-Miller (L-M), Orr-Sherby-Dorn (O-S-D) and Manson-Haferd (M-H) etc. time-temperature parametric (TTP) methods. Standard error of estimate (SEE) values for the each parameter was obtained with different temperatures through the statistical process of the creep data. The results of L-M, O-S-D and M-H methods showed good creep-life prediction, but M-H method showed better agreement than L-M and O-S-D methods. Especially, it was found that SEE values of M-H method at $700^{\circ}C$ were lower than that of L-M and O-S-D methods.

  • PDF

Non-destructive estimation of soluble solids in the intact melon fruits from cross progeny by non-contact mode with a fiber optic probe

  • Ito, Hidekazu;Fukino, Nobuko
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1524-1524
    • /
    • 2001
  • A previous paper(Ito et al., 2000) has described the improvement of the standard error(SEC and SEP) of the predicted soluble solids(Brix) in a melon cultivar by non-contact mode with a fiber optic probe. Then we examined the immature and mature fruits. The objective of this study was to determine if non-contact mode could improve the standard error of the predicted Brix of matured melon fruits from cross progeny as well as the contact mode(usual method). The optical absorption spectrum was measured using a NIR Systems model 6500 spectrophotometer. A commercial spectral program(NSAS ver. 3.27) was used for multiple linear regression analysis. Absorbances of 902 and in the vicinity of 877 nm were included as the independent variables in both multiple regression equations. These wavelengths are key wavelengths for non-destructive Brix determination. When the results for the contact mode and non-contact mode are compared, the latter mode improved the former standard error(SEP and RMS).

  • PDF

An Extended TRL Calibration Method (확장된 TRL 오차 수정 방법)

  • Kim Yusin;Lee Chang-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.11 s.102
    • /
    • pp.1099-1105
    • /
    • 2005
  • TRL error correction method is widely used for measuring high frequency device mounted on PCB. In order to correct error more precisely, the characteristic impedance of standard transmission line should be known mounted for error correction. The capacitance per the unit length of transmission line is calculated by using standard transmission line which terminate resistor additionally at previous method and the characteristic impedance of standard transmission line is calculated with fitting method according to frequency, but the characteristic impedance extracted by a manufacturing inaccuracy is influenced. In this study, a novel method can reduce the manufacturing inaccuracy using measured s-parameters and can extract more accurate characteristic impedance than the previous method.

Comparison of Efficiency between Individual Randomization and Cluster Randomization in the Field Trial (지역사회 임상시험시 개인별 무작위배정과 군집 무작위배정의 효율성 비교)

  • Koo, Hye-Won;Kwak, Min-Jeong;Lee, Young-Jo;Park, Byung-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.1
    • /
    • pp.51-55
    • /
    • 2000
  • Objectives . In large-scale field trials, randomization by cluster is frequently used because of the administrative convenience, a desire to reduce the effect of treatment contamination, and the need to avoid ethical issues that might of otherwise arise. Cluster randomization trials are experiments in which intact social unit, e.g., families, schools, cities, rather than independent individuals are randomly allocated to intervention groups. The positive correlation among responses of subjects from the same cluster is in matter in cluster randomization. This thesis is to compare the results of three randomization methods by standard error of estimator of treatment effect. Methods : We simulated cholesterol data varing the size of the cluster and the level of the correlation in clusters and analyzed the effect of cholesterol-lowering agent. Results : In intra-cluster randomization the standard error of the estimator of treatment effect is smallest relative to that in inter-cluster randomization and that in individual randomization. Conclusions : Infra-cluster randomization is the most efficient in its standard error of estimator of treatment effect but other factor should be considered when selecting a specific randomization method.

  • PDF

Inter-comparison between ultrasonic interferometer manometer and medium vacuum standards by static expansion method (초음파간섭 수은주압력계와 정적법 중진공 국가표준기 상호비교)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.103-109
    • /
    • 2005
  • A new medium vacuum primary standard using the static expansion method was developed in KRISS. In order to evaluate the performance of the equipment, we compared the medium vacuum standard with an ultrasonic interferometer manometer using two capacitance diaphragm gauges, the measuring ranges of which were 133 Pa and 1,333 Pa respectively. The result, Error normalized values, showed that the two standards are coincident each other within the range of combined uncertainty at calibrated pressure of $3pa\;\sim\;100pa$.