• Title/Summary/Keyword: Standard electrode potential

Search Result 74, Processing Time 0.022 seconds

Micromachined pH Sensor Using Open Well Structures (개방형 우물 구조를 이용한 마이크로머신형 pH 센서)

  • Kim, Heung-Rak;Kim, Young-Deog;Jeong, Woo-Cheol;Kim, Kwang-Il;Kim, Dong-Su
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • A structure of a glass electrode-type pH sensor for measuring any concentration of $H^+$ in an aqueous solution was embodied with bulk micromachining technology. Two open well structures were formed, and a reference electrode was secured by the Ag/AgCl thin film in the sloped side of the etched structure. A sensitive membrane of an indicator electrode for generating a potential by an exchange reaction to $H^+$ was made with a glass containing Na 20% or more finely so that its thickness might be $100{\mu}m$ or so, and then it was bonded to one pyramidal structure. A liquid junction for a current path was formed by filling an agar in the anisotropically etched part of the Si wafer, which had a size of $50{\mu}m{\times}50{\mu}m$, and then bonded it to the other. After complete fabrication of each part, it was filled with a 2M KCl reference solution and encapsulated the sensor structure with a cold expoxy. The potential value of fabricated pH sensor was about 90mV/pH in the standard pH solutions.

Determination of Inorganic Phosphate in Paprika Hydroponic Solution using a Laboratory-made Automated Test Stand with Cobalt-based Electrodes (코발트전극과 자동시험장치를 이용한 파프리카 양액 내 무기인산 측정)

  • Kim, Hak-Jin;Son, Dong-Wook;Kwon, Soon-Goo;Roh, Mi-Young;Kang, Chang-Ik;Jung, Ho-Seop
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.326-333
    • /
    • 2011
  • The need for rapid on-site monitoring of hydroponic macronutrients has led to the use of ion-selective electrodes, because of their advantages over spectrophotometric methods, including simple methodology, direct measurement of analyte, sensitivity over a wide concentration range, and low cost. Stability and repeatability of response can be a concern when using multiple ion-selective electrodes to measure concentrations in a series of samples because accuracy might be limited by drifts in electrode potential. A computer-based measurement system could improve accuracy and precision because of both consistent control of sample preparation and easy calibration of sensors. Our goal was to investigate the applicability of a cobalt-based electrode used in conjunction with a laboratory-made automated test stand for quantitative determination of ${PO_4}^-$ in hydroponic solution. Six hydroponic solutions were prepared by diluting highly concentrated paprika hydroponicsolution to provide a concentration range of 1 to 300 ppm $PO_4$-P. A calibration curve relating electrode response to phosphate in paprika hydroponic solution titrated to pH 4 with 0.025M KHP was developed based on the Nikolskii-Eisenman equation with a coefficient of determination ($R^2$) of 0.94. The laboratory-made test stand consisting of three cobalt-based electrodes measured phosphate concentrations similar to those obtained with standard laboratory methods (a regression slope of 0.98 with $R^2$ = 0.80). However, the y intercept was relatively high, 30 ppm, probably due to the relatively large amount of variation present among multiple measurements of the same sample. Further studies on the high variation in EMFs obtained with cobalt electrodes during replicate measurements were required for P estimations comparable to those obtained with standard laboratory instruments.

Determination of Adsorption Isotherms of Hydroxide ata Platinum Electrode Interface Using the Phase-Shift Method and Correlation Constants

  • Chun, Jin-Y.;Chun, Jang-H.
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.3
    • /
    • pp.219-228
    • /
    • 2007
  • The phase-shift method and correlation constants, i.e., the electrochemical impedance spectroscopy (EIS) techniques for studying linear relationships between the behaviors (${\varphi}\;vs.\;E$) of the phase shift ($0^{\circ}{\leq}-{\varphi}{\leq}90^{\circ}$) for the optimum intermediate frequency and those (${\theta}\;vs.\;E$) of the fractional surface coverage ($1{\geq}{\theta}{\geq}0$), have been proposed and verified to determine the Langmuir, Frumkin, and Temkin adsorption isotherms (${\theta}\;vs.\;E$) of H for the cathodic $H_2$ evolution reaction (HER) at noble and transition-metal/aqueous solution interfaces. At the Pt/0.1 MKOH aqueous solution interface, the Langmuir, Frumkin, and Temkin adsorption isotherms (${\theta}\;vs.\;E$), equilibrium constants ($K=5.6{\times}10^{-10}\;mol^{-1}\;at\;0{\leq}{\theta}<0.81$, $K=5.6{\times}10^{-9}{\exp}(-4.6{\theta})\;mol^{-1}\;at\;0.2<{\theta}<0.8$, and $K=5.6{\times}10^{-10}{\exp}(-12{\theta})\;mol^{-1}\;at\;0.919<{\theta}{\leq}1$, interaction parameters (g = 4.6 for the Temkin and g = 12 for the Frumkin adsorption isotherm), rates of change of the standard free energy ($r=11.4\;kJ\;mol^{-1}$ for g=4.6 and $r=29.8\;kJ\;mol^{-1}$ for g=12), and standard free energies (${\Delta}G_{ads}^0=52.8\;kJ\;mol^{-1}\;at\;0{\leq}{\theta}<0.81,\;49.4<{\Delta}G_{\theta}^0<56.2\;kJ\;mol^{-1}\;at\;0.2<{\theta}<0.8$ and $80.1<{\Delta}_{\theta}^0{\leq}82.5\;kJ\;mol^{-1}\;at\;0.919<{\theta}{\leq}1$) of OH for the anodic $O_2$ evolution reaction (OER) are also determined using the phase-shift method and correlation constants. The adsorption of OH transits from the Langmuir to the Frumkin adsorption isotherm (${\theta}\;vs.E$), and vice versa, depending on the electrode potential (E) or the fractional surface coverage (${\theta}$). At the intermediate values of ${\theta}$, i.e., $0.2<{\theta}<0.8$, the Temkin adsorption isotherm (${\theta}\;vs.\;E$) correlating with the Langmuir or the Frumkin adsorption isotherm (${\theta}\;vs.\;E$), and vice versa, is readily determined using the correlation constants. The phase-shift method and correlation constants are accurate and reliable techniques to determine the adsorption isotherms and related electrode kinetic and thermodynamic parameters. They are useful and effective ways to study the adsorptions of intermediates (H, OH) for the sequential reactions (HER, OER) at the interfaces.

Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode

  • Ly, Suw-Young;Lee, Hyun-Kuy;Kwak, Kyu-Ju;Ko, Jun-Seok;Lee, Jeong-Jae;Cho, Jin-Hee;Kim, Ki-Hong;Kim, Min-Seok;Lee, So-Jung
    • Toxicological Research
    • /
    • v.24 no.3
    • /
    • pp.227-233
    • /
    • 2008
  • To detect lead ions using electrochemical voltammetric analysis, Infrared Photo-Diode Electrode(IPDE) was applied via cyclic and square wave stripping voltammetry. Lead ions were deposited at 0.5 V(versus Ag/AgCl) accumulation potential. Instrumental measurements systems were made based on a simple and compact detection system. The stripping voltammetric and cyclic voltammetric optimal parameters were searched. The results yielded a cyclic range of $40{\sim}240mgl^{-1}$ Pb(II) and a square wave stripping working range of $0.5{\sim}5.00mgl^{-1}$ Pb(II). The relative standard deviation at 2 and 4 $mgl^{-1}$ Pb(II) was 0.04% and 0.02%(n=15), respectively, using the stripping voltammetric conditions. The detection limit was found to be 0.05 $mgl^{-1}$ with a 40 sec preconcentration time. Analytical interference ions were also evaluated. The proposed method was applied to determine lead ions in various samples.

Zr 도핑 및 열처리 온도에 따른 용액 공정 기반 ZTO:Zr 트랜지스터의 특성 연구

  • Kim, Sang-Seop;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.214.2-214.2
    • /
    • 2015
  • 본 연구에서는 Zr을 첨가한 용액 공정 기반 ZTO:Zr 산화물 반도체 제작 및 열처리 온도에 따른 트랜지스터의 특성 변화를 분석하였다. Zn:Sn=4:7 비율로 고정하고, Zr (0~1%) 비율에 따른 도핑과 열처리 온도($350{\sim}550^{\circ}C$)를 가변하였다. 실험 결과, Zr의 비율이 증가할수록 전류와 이동도가 감소하였고, 문턱전압이 양의 방향으로 이동하는 것을 확인하였다. Zr는 SEP (Standard Electrode Potential)가 -1.45로 Zn (-0.76), Sn (-0.13) 보다 작아 금속과 산소의 결합을 증가시키며, 또한 밴드갭이 ~7 eV로 다른 금속 보다 높아 산소와 결합력이 높다. 이러한 요인은 산화물 내의 산소 원자 결함(Oxygen vacancy)을 감소시킨다. 반대로 열처리 온도가 높아질수록 탈 수산화(Dehydroxylation)로 인한 산소 원자 결함이 증가시켜, Zr 도핑 효과와 반대 경향을 보인다. 실험 결과를 통해 Zr:Zn:Sn=0.5:4:7의 비율과 $550^{\circ}C$ 열처리 조건에서 문턱전압과 이동도, 아문턱 스윙, 전류 온오프 비(Ion/Ioff)가 각각 0.68V, $0.18cm^2/Vs$, 1.06 V/dec, $1.6{\times}10.6$의 특성을 확인하였다.

  • PDF

Fabrication and Charaterization of Oxide Thin Film Transistor (산화물반도체 박막트랜지스터 제작 및 전기적 특성 분석)

  • Lee, Sang Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.275-277
    • /
    • 2013
  • Thin-film transistors(TFTs) with silicon zinc tin oxide(SZTO) channel layer are fabricated by solution-process. The threshold voltage ($V_{th}$) shifted toward positive directly with increasing Si contents in SZTO system. Because the Si has a lower standard electrode potential (SEP) than Sn, Zn, thus degenerate the oxygen vacancy (VO). As a result, the Si act as carrier suppressor and oxygen binder in the SZTO as well as a $V_{th}$ controller.

Investigation on the Stability Enhancement of Oxide Thin Film Transistor (산화물반도체 트랜지스터 안정성 향상 연구)

  • Lee, Sang Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.5
    • /
    • pp.351-354
    • /
    • 2013
  • Thin-film transistors(TFTs) with silicon-zinc-tin-oxide(SiZnSnO, SZTO) channel layer are fabricated by rf sputtering method. Electrical properties were changed by different annealing treatment of dry annealing and wet annealing. This procedure improves electrical property especially, stability of oxide TFT. Improved electrical properties are ascribed to desorption of the negatively charged oxygen species from the surfaces by annealing treatment. The threshold voltage ($V_{th}$) shifted toward positive as increasing Si contents in SZTO system. Because the Si has a lower standard electrode potential (SEP) than that that of Sn, Zn, resulting in the degeneration of the oxygen vacancy ($V_O$). As a result, the Si acts as carrier suppressor and oxygen binder in the SZTO as well as a $V_{th}$ controller, resulting in the enhancement of stability of TFTs.

Electrical Properties of Mg Doped ZnSnO TFTs Fabricated by Solution-process (용액공정을 이용한 ZnSnO 산화물 반도체 박막 트랜지스터에서 Mg 첨가에 따른 영향)

  • Choi, Jun-Young;Park, Ki-Ho;Kim, Sang-Sig;Lee, Sang-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.9
    • /
    • pp.697-700
    • /
    • 2011
  • Thin-film transistors(TFTs) with magnesium zinc tin oxide(MZTO) channel layer are fabricated by solution-process. The threshold voltage (Vth) shifted toward positive directly with increasing Mg contents in MZTO system. Because the Mg has a lower standard electrode potential (SEP) than Sn, Zn, thus degenerate the oxygen vacancy ($V_O$). As a result, the Mg act as carrier suppressor and oxygen binder in the MZTO as well as a Vth controller.

Anodic Stripping Voltammetric Determination of Cadmium(Ⅱ) Using Alga-Modified Carbon Paste Electrodes (Alga변성전극을 이용한 Cadmium(Ⅱ)의 양극벗김 전압-전류법적 정량)

  • Bae, Zun Ung;Choi, Jung Eun;Chang, Hye Young
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.1
    • /
    • pp.28-35
    • /
    • 1998
  • Microorganisms such as alga are able to uptake toxic and heavy metal ions. After Cd(Ⅱ) was preconcentrated on the carbon paste electrode constructed by incorporating alga (Anabaena), it was determined with differential pulse anodic stripping voltammetry. A well-defined oxidation peak of Cd(Ⅱ) was obtained at - 0.75 V vs. SCE. We investigated the optimum conditions using the peak, which are the effect of the amount of alga, pH, ionic strength, temperature, and preconcentration time on the preconcentration of Cd(Ⅱ) and that of the reduction time and potential on the reduction of Cd(Ⅱ) preconcentrated. Calibration curve for the determination of Cd(Ⅱ) was linear over the range of $1.0{\times}10^6\;M\;to\;8.0{\times}10^6$\;M (R=0.9978) and the detection limit was $5.0{\times}10^{-7}$\;M. The relative standard deviation was 3.1% (n=6) for $7.0{\times}10^{-6}\;M Cd(Ⅱ). In regeneration of the electrode surface with 0.1 M HCl, the response was reproducible continuously by 10 times.

  • PDF

Electrochemical Studies of o-Cresolphthalexon at Mercury Electrode in Alkaline Media (염기성용액 중의 수은전극에서 o-Cresolphthalexon의 전기화학적 연구)

  • Chong-Min Pak;Sam-Woo Kang;Lee-Mi Do;Tae Yoon Eom;Ki-Suk Jung
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.158-164
    • /
    • 1991
  • The reduction mechanism at a mercury electrode of o-cresolphthalexon(OCP) in strongly alkaline supporting electrolytes has been investigated by several electrochemical techniques. The radical formed after first one electron reduction uptake, dimerizes. The result of cyclic voltammetric investigation demonstrated the reversible nature of the electron transfer and standard rate constant was $3.27{\times}10^{-2}$ cm/sec. The apparent irreversible behavior of the second wave is a result of the existence of a fast protonation following the second electron transfer. At low concentration of OCP(< $1{\times}10^{-4}$M), cathodic current were remarkably adsorptive properties. Prolonged electrolysis was carried out at controlled potential of -1.85V, original violet color of the solution becames progressively weaker, and then colorless solution. The final product of an exhaustive electrolysis is electro-inactive. The appearence of four steps may be explained by the fact that the reduction of OCP elucidated ECEC mechanism.

  • PDF