• 제목/요약/키워드: Standard diagnostic reference level

검색결과 17건 처리시간 0.029초

당뇨환자에서 자가관리형 베타케톤검사의 유효성: 체계적 문헌 고찰 및 메타분석 (The Effectiveness of Blood β-ketone Testing in Patients with Diabetic Ketosis: A Systematic Review & Meta-analysis)

  • 모진아;장선영;방희영
    • 보건교육건강증진학회지
    • /
    • 제31권4호
    • /
    • pp.1-10
    • /
    • 2014
  • Objectives: The effectiveness of Blood ${\beta}$-ketone testing by using self-monitoring strip on diabetic patients. Methods: Clinical effectiveness of blood ${\beta}$-ketone testing was assessed through correlation with reference test that measured blood ${\beta}$-ketone value through gas chromatography or enzyme method, diagnostic accuracy, time taken for the test and time taken for confirmative diagnosis of diabetic ketosis by selecting literatures on researches that conducted this test on ketosis(suspected) patients or diabetic ketosis(suspected) patients. Each of the stages from literature search to application of selection standards and extraction of data were carried out independently by the Subcommittee along with 2 researchers. Results: 7 reports were selected. ${\beta}$-ketone testing displayed high level of correlation in the range of r=0.92~0.99 with test using enzyme method as the reference standard. Regarding the diagnostic accuracy, sensitivity of 0.82, specificity of 0.74. The time taken for the test was 30seconds for the index test, which is shorter than reference standard test. Conclusion: Blood ${\beta}$-ketone testing was assessed to be a safe and effective test to monitor ketosis and assess the level of risk of ketosis by measuring the blood ${\beta}$-ketone on ketosis patients and diabetic ketosis patients since it has high level of correlation with reference test and short period of testing.

제조업 특성을 반영한 스마트공장 진단모델 개발 및 중소기업 맞춤형 적용사례 (Development of Smart Factory Diagnostic Model Reflecting Manufacturing Characteristics and Customized Application of Small and Medium Enterprises)

  • 김현득;김동민;이경근;윤제환;염세경
    • 산업경영시스템학회지
    • /
    • 제42권3호
    • /
    • pp.25-38
    • /
    • 2019
  • This study is to develop a diagnostic model for the effective introduction of smart factories in the manufacturing industry, to diagnose SMEs that have difficulties in building their own smart factory compared to large enterprise, to identify the current level and to present directions for implementation. IT, AT, and OT experts diagnosed 18 SMEs using the "Smart Factory Capacity Diagnosis Tool" developed for smart factory level assessment of companies. They analyzed the results and assessed the level by smart factory diagnosis categories. Companies' smart factory diagnostic mean score is 322 out of 1000 points, between 1 level (check) and 2 level (monitoring). According to diagnosis category, Factory Field Basic, R&D, Production/Logistics/Quality Control, Supply Chain Management and Reference Information Standardization are high but Strategy, Facility Automation, Equipment Control, Data/Information System and Effect Analysis are low. There was little difference in smart factory level depending on whether IT system was built or not. Also, Companies with large sales amount were not necessarily advantageous to smart factories. This study will help SMEs who are interested in smart factory. In order to build smart factory, it is necessary to analyze the market trends, SW/ICT and establish a smart factory strategy suitable for the company considering the characteristics of industry and business environment.

몬테카를로 시뮬레이션을 이용한 국내 일반엑스선검사 진단참고수준의 유효선량 평가 (Evaluation of Effective Dose with National Diagnostic Reference Level using Monte-Carlo Simulation)

  • 이승열;성열훈
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.1041-1047
    • /
    • 2021
  • 본 연구에서는 국가에서 제공하는 일반엑스선검사의 진단참고수준 중 다빈도 검사에 대한 유효선량을 몬테카를로 시뮬레이션을 이용하여 평가하고자 하였다. 일반엑스선검사의 진단참고수준에 대한 유효선량 평가는 가장 다빈도로 검사되는 두부 전후면(Anterior-Posterior; AP), 흉부 후전면(Posterior-Anterior; PA), 흉부 측면(Lateral; LAT), 복부 AP, 골반 AP 등 총 5개의 검사 부위로 선정하였다. 몬테카를로 시뮬레이션에 사용되는 관전압과 관전류 등의 물리적 조건은 국내 조건의 대표성을 나타내기 위해 질병관리청의 자료를 사용하였다. 국내 의료방사선 피폭량 평가를 위해 사용된 인체 전산 팬텀은 한국인의 표준 체형을 대표할 수 있고 국제규격의 ICRP 103 기반으로 제작된 HDRK-Man 전산 인체팬텀을 몬테카를로 시뮬레이션에 적용하였다. 그 결과, 성인 남성을 기준으로 두부 AP의 진단참고수준에 해당되는 유효선량은 0.086 mSv, 흉부 PA는 0.05 mSv, 흉부 LAT는 0.354 mSv, 복부 AP는 0.548 mSv, 골반 AP는 0.451 mSv로 평가되었다.

직류전동차용 피뢰기 진단기술 (Diagnostic Techniques of Lightning Arresters for DC Electric Traction Vehicles)

  • 길경석;송재용;김일권;문승보;신광철
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.357-361
    • /
    • 2006
  • This paper dealt with the performance evaluation and the diagnostic techniques of lightning arresters for DC electric traction vehicle. Field Measurements on the protective operation of lightning arresters against surge currents were carried out on running vehicles to acquire the data necessary for the diagnosis. The frequency and the magnitude of surge events were analyzed. Surge currents of $1\sim3$ times were recorded in one running service route and their magnitudes were ranges of $150A\sim2kA$. Also, an acceleration experiment on a lightning arrester by the standard lightning impulse current of 8/20 us and 5 kA was performed to know the aging characteristics. After the surge current application of 3,000 times, the reference voltage decreased by 4.5 %, and the leakage current was below 10 uA at the continuous operating voltage and about 50 uA at the rated voltage. From the experimental results, we propose a decision level of leakage current for the arrester used in this paper and designed an arrester tester which analyzes arrester condition by the magnitude of leakage current.

Is the diagnosis of calcified laryngeal cartilages on panoramic radiographs possible?

  • Cagirankaya, Leyla Berna;Akkaya, Nursel;Akcicek, Gokcen;Dogru, Hatice Boyacioglu
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.121-125
    • /
    • 2018
  • Purpose: Detecting laryngeal cartilages (triticeous and thyroid cartilages) on panoramic radiographs is important because they may be confused with carotid artery calcifications in the bifurcation region, which are a risk factor for stroke. This study assessed the efficiency of panoramic radiography in the diagnosis of calcified laryngeal cartilages using cone-beam computed tomography (CBCT) as the reference standard. Materials and Methods: A total of 312 regions(142 bilateral, 10 left, 18 right) in 170 patients(140 males, 30 females) were examined. Panoramic radiographs were examined by an oral and maxillofacial radiologist with 11 years of experience. CBCT scans were reviewed by 2 other oral and maxillofacial radiologists. The kappa coefficient(${\kappa}$) was calculated to determine the level of intra-observer agreement and to determine the level of agreement between the 2 methods. Diagnostic indicators(sensitivity, specificity, accuracy, and false positive and false negative rates) were also calculated. P values <.05 were considered to indicate statistical significance. Results: Eighty-two images were re-examined to determine the intra-observer agreement level, and the kappa coefficient was calculated as 0.709 (P<.05). Statistically significant and acceptable agreement was found between the panoramic and CBCT images (${\kappa}=0.684$ and P<.05). The sensitivity, specificity, diagnostic accuracy rate, the false positive rate, and the false negative rate of the panoramic radiographs were 85.4%, 83.5%, 84.6%, 16.5%, and 14.6%, respectively. Conclusion: In most cases, calcified laryngeal cartilages could be diagnosed on panoramic radiographs. However, due to variation in the calcifications, diagnosis may be difficult.

소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구 (A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography)

  • 김현진;이효영;임인철;유윤식
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.161-169
    • /
    • 2016
  • 본 연구에서는 소아 두부 CT 검사에 있어서 피폭 방사선량을 경감할 수 있는 방법을 모색하고자 부산지역 병원들에서 시행된 년 간 소아 두부 CT 검사에 대한 CT 선량지표(CTDI)를 국내 진단참고준위와 비교하여 분석함으로써 제안점을 도출하고자 하였다. 결과적으로 병원별 분류에서는 병원, 종합병원, 상급종합병원 순으로 권고량이 초과하는 것으로 나타났으며 연령별 분류에서는 2-5세 이하, 1개월-1세 이하, 6-10세 이하 순으로 권고량이 초과하는 것으로 나타났다. 스캔방식별 분류에서는 Helical, Axial, Volume방식 순으로 권고량이 초과하고 있었으며 스캔범위를 진단참고준위에 맞게 재설정한 결과 상급종합병원에서 재설정으로 인한 감소율은 11.68%, 종합병원에서 15.79%, 병원에서 20.66%로 초과율이 높게 나타났다. 그리고 환자선량 권고량 가이드라인을 벗어나지 않는 환자의 평균 스캔범위의 분석결과 1개월-1세 이하에서 $103.2{\pm}11.8mm$, 2-5세 이하에서 $110.5{\pm}14.5mm$, 6-10세 이하에서는 $117.8{\pm}17.2mm$로 나타났다.

전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가 (Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System)

  • 우민선;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.455-464
    • /
    • 2012
  • 본 연구는 일반 X선 검사에서 CR 시스템을 이용한 환자의 근사적 피폭 선량을 평가할 수 있는 실험적 모델을 제시하고 저선량 영역에서 의료 피폭에 대한 방어의 최적화 조건으로 환자의 선량 권고량(diagnostic reference level. DRL)을 비교하고자 하였다. 이를 위하여 기준선량계와 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)를 이용하여 관전압(kVp) 및 관전류 노출시간의 곱(mAs)에 따른 입사표면선량(entrance surface dose. ESD)을 교차 측정하였으며 CR 시스템에서 각 노출 조건에 대한 Hounsfield unit (HU) scale을 측정하여 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적 피폭 선량을 구하였다. 또한 임상적으로 적용 가능한지를 알기 위하여 두부, 경부, 흉부, 복부, 골반부 노출 조건으로 물 팬텀에 모사하여 피폭 선량을 구하였다. 결과적으로 두 선량계의 평균 ESD는 각각 2.10, 2.01, 1.13, 2.97, 1.95 mGy 이었으며 CR 영상에서 측정한 HU 스케일은 각각 $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, $2,318{\pm}4.64$ 이었다. 이 때 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적으로 구한 ESD는 각각 2.16, 2.06, 1.19, 3.05, 2.07 mGy이었으며 평균 측정값과 근사적으로 구한 ESD의 오차는 3% 미만으로 영상의학 분야의 측정 오차 5%를 감안한다면 신뢰할 수 있는 오차 범위라 할 수 있었다. 결론적으로 CR 시스템을 이용한 일반 X선 검사에서 환자의 피폭 선량을 근사적으로 평가할 수 있는 새로운 실험적 모델을 제시하였으며 CR 검사뿐 만 아니라 디지털 방사선촬영(digital radiography. DR) 시스템 및 필름-증감지 시스템에 적용 가능할 것으로 판단되었다.

소아 두부 전산화단층촬영 선량지표 분석을 통한 피폭선량 모니터링: 일개병원 사례 중심으로 (Analyzed the Computed Tomography Dose Index (CTDI) to the Pediatric Brain CT by Reason of the Observation for the Exposure Dose: Base on a Hospital)

  • 이재승;김현진;임인철
    • 한국콘텐츠학회논문지
    • /
    • 제15권6호
    • /
    • pp.290-296
    • /
    • 2015
  • 본 연구는 일개병원에서 시행된 년간 소아 두부 CT 검사에 대한 CT 선량지표(CTDI)를 국내 진단참고 준위와 비교하여 분석함으로써 제안점을 도출하고 피폭 방사선량 저감화 방안을 제시하고자 하였다. 이를 위하여 2014년 1월부터 12월까지 두부 손상으로 소아 두부 CT 검사를 의뢰 받은 10세 미만의 소아 231명을 후향적으로 조사하였다. 조사 방법은 선량 보고서와 의료전자차트를 참조하여 일반적 특성, 관전압(kVp), 관전류(mA), 검사 범위, $CTDI_{vol}$, DLP를 조사하여 분석하였다. 결과적으로 $CTDI_{vol}$은 전체 연구대상자의 7.4%(17명)가 국내 진단참고준위를 초과한 것으로 나타났으며 DLP의 경우 41.6%(96명)가 초과 되어 $CTDI_{vol}$ 보다 비교적 높게 나타났다. DLP는 한국식품의약품안전처에서 제시한 CT 선량 지표보다 대부분 약 60% 이상 초과되었으며 건강보험심사평가원에서 제시한 기준 검사 범위보다 약 30%이상 증가된 검사 범위가 DLP가 높게 나타난 원인으로 분석되었다. 결론적으로 임상에서 CT 검사 시 건강보험심사 평가원에서 제시하는 소아 두부 CT 검사의 기준 검사 범위를 준수하여 검사하고 프로토콜을 적절히 조절한다면 피폭선량을 상당히 낮출 수 있을 것으로 판단된다.

COVID-19 진단을 위한 CT 검사: 프로토콜, 방사선량에 대한 체계적 문헌고찰 및 진단을 위한 CT 검사량 (CT Examinations for COVID-19: A Systematic Review of Protocols, Radiation Dose, and Numbers Needed to Diagnose and Predict)

  • 이종혁;홍현숙;김형진;이창현;구진모;윤순호
    • 대한영상의학회지
    • /
    • 제82권6호
    • /
    • pp.1505-1523
    • /
    • 2021
  • 목적 Coronavirus disease 2019 (이하 COVID-19) 폐렴에서 CT를 일차 진단 검사로 사용하고자 하는 논의가 있지만, 대규모 인구에게 CT 검사를 적용했을 때의 상황을 고찰한 연구는 없었다. 본 연구에서는 COVID-19 폐렴을 다룬 연구들에서 CT 프로토콜과 방사선량을 분석하고, CT 검사가 일차 진단 검사법으로 사용될 때 필요한 CT 검사량에 대해 알아보고자 한다. 대상과 방법 본 연구는 9개의 인용도가 높은 영상의학과 저널에서 COVID-19 폐렴의 CT 기반 진단을 다룬 문헌들을 검색하였다. 먼저, 연구에서 제시된 CT 프로토콜, 방사선량을 조사하여, 이를 해당 국가의 diagnostic reference level과 비교하였다. 추가로, COVID-19에 대한 CT 민감도 94%, 특이도 37%를 적용하여, 우한시와 뉴욕, 이탈리아의 초기 COVID-19 outbreak에서 polymerase chain reaction (이하 PCR) 검사 양성률에 기반한 number needed to diagnose (이하 NND)와 number needed to predict (이하 NNP)를 계산하였다. 결과 총 86개의 연구가 검색되었고, 그중 CT 프로토콜은 81개의 연구에서(94.2%), 방사선량은 17개의 연구에서(19.8%) 보고되었다. 저선량 흉부 CT는 표준선량 흉부 CT보다 2배 많은 연구에서 활용되었다(39.5% vs. 18.6%). 방사선량을 보고한 17개의 연구들 중, 15개의 연구에서 방사선량은 해당 국가의 diagnostic reference level 수치보다 낮았다(88.2%). COVID-19에 대한 CT 민감도 94%, 특이도 37%를 적용하였을 때, NND는 3.2회 CT scans으로 나타났다. 한편, PCR 검사 양성률 50%, 25%, 10%, 5%에서의 한 명의 COVID-19 환자를 진단 위한 CT 검사량을 나타내는 NNP는 각각 2.2, 3.6, 8.0, 15.5회의 CT scans로 나타났다. 우한 시에서는 최종 17365명의 COVID-19 환자를 진단하기 위하여 약 35418명에서(PCR 검사 양성률 58%) 44840명(PCR 검사 양성률 38%)의 사람들이 CT 검사를 받은 것으로 나타났다. 뉴욕시와 이탈리아의 초기 COVID-19 유행 10주간, PCR 검사 양성률에 따라 일 CT 검사량이 최대 5.4, 10.9배까지 변화하였다. 결론 CT를 COVID-19에 대한 일차적인 진단검사로 사용할 경우, PCR 검사 양성률에 따라 CT 검사량은 변동량이 크고, 이는 추후 판데믹 상황에서 고려되어야 할 것이다.

건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고 (Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center)

  • 김정수;정혜경;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.13-17
    • /
    • 2016
  • 모든 의료방사선 검사는 정당성과 최적화가 확보되어야 한다. 특히 질병의 예방과 조기 진단을 목적으로 하는 건강검진에서 방사선 피폭의 최적화를 위한 모니터링은 절대적으로 필요하다. 본 연구에서는 DICOM 규격을 이용하여 건강검진센터의 의료방사선 피폭 품질관리 사례에 대해 보고하고자 한다. 적용된 시스템을 이용하여 건강검진센터의 진단참고 값을 제정하고 이를 통한 품질관리를 시행하였다. CT에서는 전체 703명에 대한 진단참고 값으로 복부검사에서 $357.9mGy{\cdot}cm$, 두부검사에서 $572.38mGy{\cdot}cm$, 심장혈관 칼슘검사에서 $55.92mGy{\cdot}cm$, 저선량 폐 검사에서 $53.98mGy{\cdot}cm$, 경추 검사에서 $284.99mGy{\cdot}cm$, 요추 검사에서 $341.85mGy{\cdot}cm$를 도출 하였으며, 흉부 X선 검사 1955건에 대해 $274.0mGy{\cdot}cm$2과 유방 촬영에서는 6.09 mGy의 진단참고 값를 도출하였다. 본 연구에서 개발된 시스템은 건강검진센터에서 수검자에 조사되는 방사선의 피폭선량을 실시간으로 모니터링하고 이를 이용한 피폭선량의 최적화와 정당화를 위한 품질관리 도구로 활용될 것이다.