• Title/Summary/Keyword: Standard body measurement

검색결과 266건 처리시간 0.024초

남자 중학생의 비만도에 따른 체중조절, 식습관 연구 (A Study of the Body Weight Control and Dietary Habits According to the Obese Index in Male Middle School Students)

  • 손신미;박은숙
    • 대한지역사회영양학회지
    • /
    • 제11권6호
    • /
    • pp.683-694
    • /
    • 2006
  • The purpose of this study was to determine the body weight control, food habits and nutrient intakes according to the obese index in male middle school students. This study was carried out through questionnaires and measurement by body fat analyzer (Inbody 4.0). The subjects were 275 male middle school students in Iksan. Chonbuk province. The average age, height, weight, and BMI of the subjects were 14.4 years old, 167.8 cm, 60.2 kg and $21.3kg/m^2$, respectively. Seventeen point one percent of the subjects were the underweight group, 47.6% were the normalweight group, and 35.3% were the overweight group by the classification of the Korean Pediatrics Society standard. Body fat of underweight, normalweight, and overweight were 16.1%, 19.0%, and 26.6%, respectively. Thirty one point nine percent of underweight, 39.7% of normalweight. and 31.9% of overweight had misperceptions of their weight (p<0.001). Sixty two point two percent of the males were dissatisfied with their body weight, and 55.3% of the whole tried to reduce their body weights. Even though they were normalweight, half of them dissatisfied with their weight. The source of weight control method was friends and family, TV radio, Internet, and school nutrition education, in order. The subjects exercised 3.4 days per week, 70.2 minutes per day, but it was not different significantly by the obese index. Forty percent of the subjects had meals fast, 58.5% of them have biased food habits even if they didn't differ by the obese index. Activity rate was different by the obese index significantly (p < 0.05), the number of severe activity was most in underweight. In conclusion, nutrition education programs should contain the necessity of normalweight, and regularity of lift habits and activities for energy expenditure in overweight students. It made them to recognize their weight correctly, establish healthy body images, and raise the ability to promote health and improve nutritional status.

체형측정 방법에 따른 사상체질 진단정확률 비교 연구 (Comparative Study of Diagnostic Accuracy Rate by Sasang Constitutions on Measurement Method of Body Shape)

  • 김종원;설유경;최재중;권석동;김규곤;이용태
    • 동의생리병리학회지
    • /
    • 제21권1호
    • /
    • pp.338-346
    • /
    • 2007
  • For Objectivity development of the body shape that is an importance standard for the classification of sasang constitutional medicine diagnosis, We made a comparison between Automatic & Physical measuring. This study uses 2 attitude which lies down & standing. We measured the body of patients(Width 5 places and circumference 8 places) and analyzed the anthropometric data dividing into sex, age, BMI. 296 patients's data are used in the analysis.

여고생의 브랜드 교복 착용실태 조사 및 브랜드교복 제품치수 비교분석에 관한 연구 (A Survey on the Brand School Uniforms for High School Girl's and Comparative Analysis on Their Size System of Brand Uniform)

  • 신경희;서추연
    • 대한가정학회지
    • /
    • 제49권10호
    • /
    • pp.49-56
    • /
    • 2011
  • The purpose of this study is to research the difference between the size suggested by brand uniforms and the size suitable for high school girls. We compared and analyzed the size system of brand uniforms after researching the wearing conditions of uniforms of 4 brands (A, B, C, D) in order to establish a size system of brand uniforms that fits different body types of teenagers. First, we conduct research on the actual condition of brand uniforms worn by high school girls, and investigate unsatisfactory factors and problems. Second, we actually measure the uniform size of each brand and analyze measurement differences between each brand. Our results show each brand uniform has different size specifications and the importance of appropriate size specification is greater as students select uniform based on design and brand awareness rather than body size. Compared with the average body size the skirt and especially the blouse is much smaller with no extra room compared with standard size 85 blouses and size 71 skirts. Therefore, the adjustment of size specification is needed in brand school uniforms. However, a larger scale investigation is needed as this study was conducted with a limited sample size.

비만체형을 위한 바지원형 연구 -학령기 남아를 중심으로 - (A Study on the Pants Pattern For the Fatty Body -The Subject of Elementary Schoolboys)

  • 조윤주;윤정혜;박정순
    • 복식
    • /
    • 제23권
    • /
    • pp.99-110
    • /
    • 1994
  • The purpose of this study was to develop the pattern drafting method which would be suitable for their physical characteristics for the fatty body of Korean elementary school boys who re more than 1.5 Rhrer's Index. The procedures of the study were as follows : We have surveyed the rate of fatty children who were more than 1.5 Rhrer's Index on 2, 185's and elementary school children. The result of research showed the rate of fatty boys in 9-11 years-old were the highest one. Therefore, body measurement and statistical analysis. 203's boys between the ages of 9-11 and over 1.5Rhrer's Index were measured on 25 items. Descriptives, correlation and factor analysis were computed. Fatty boys higher than standard boys, and bigger than grith and width items. 4 type of conventional pants pattern were collected . The most accepted conventional pants pattern was decided through wearing test. The new pattern was based on the most accepted conventional pattern, and developed through wearing test. After new pattern drafting , the sensory evaluation for appearance and comfort was applied to evaluate the new pattern by comparing it with the conventional pattern. The result of sensory evaluation , it was found that the new pattern was more suitable then the conventional pattern.

  • PDF

남자 고등학생과 남자 고등학교 사이클 선수의 신체 계측치 비교 연구 (A Comparative Study for Anthropometric Measurements of Highschool Boys and Highschool Boys Cyclist)

  • 박현정;도월희
    • 한국의류산업학회지
    • /
    • 제17권2호
    • /
    • pp.258-264
    • /
    • 2015
  • This study provides abasis for the development of high functional cycle wear with clothing comfort and fitness for highschool boy cyclists by a comparison of the somatotype of highschool boys cyclists and general highschool boys. This study directly measured 44 anthropometric targeted cyclists across Korea. "The sixth national standard physical survey" data targeted 16 to 18-year-old male adolescents; subsequently, anthropometric measurement data was provided by 766 people for research. Highschool boy cyclists used t-test to compare the differences in body type. The results in this study are follows. Highschool boys cyclists(compared to regular highschool boys) indicated a great somatotype stature and weight. The differences in the cervical height and the acromion height results of, cyclist appeared smaller. Cyclists angle of shoulder was smaller. The upper body of highschool boys cyclist was greater than the difference between chest breadth and bust breadth with along biacromion length. The waist front length of the cyclist was a short cycle ride upon the attitude of the streamlined. Highschool boy cyclists indicated that the muscles of the arm portion was more developed compared to general highschool boys. The lower body had less abdominal fat with a significantly developed thigh and calf.

A SPICE-Compatible Model for a Gate/Body-Tied PMOSFET Photodetector With an Overlapping Control Gate

  • Jo, Sung-Hyun;Bae, Myunghan;Choi, Byoung-Soo;Choi, Pyung;Shin, Jang-Kyoo
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.353-357
    • /
    • 2015
  • A new SPICE-compatible model for a gate/body-tied PMOSFET photodetector (GBT PD) with an overlapping control gate is presented. The proposed SPICE-compatible model of a GBT PD with an overlapping control gate makes it possible to control the photocurrent. Research into GBT PD modeling was proposed previously. However, the analysis and simulation of GBT PDs is not lacking. This SPICE model concurs with the measurement results, and it is simpler than previous models. The general GBT PD model is a hybrid device composed of a MOSFET, a lateral bipolar junction transistor (BJT), and a vertical BJT. Conventional SPICE models are based on complete depletion approximation, which is more applicable to reverse-biased p-n junctions; therefore, they are not appropriate for simulating circuits that are implemented with a GBT PD with an overlapping control gate. The GBT PD with an overlapping control gate can control the sensitivity of the photodetector. The proposed sensor is fabricated using a $0.35{\mu}m$ two-poly, four-metal standard complementary MOS (CMOS) process, and its characteristics are evaluated.

Improvement of Wireless Connectivity and Efficiency in E-Healthcare Service System Using a Proxy in Body Area Device

  • Kim, Sang Kon;Kim, Tae Kon;Koh, Jinhwan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권3호
    • /
    • pp.991-1013
    • /
    • 2020
  • E-health services have provided interoperability between personal health devices in personal area network, based the ISO/IEEE 11073 standard. In the healthcare system, the manager handles most agents concurrently through wireless communication. However, due to the distance limitation and the increased number of agents, it may be difficult to provide continuous connectivity. Recently, body area devices have been equipped with various applicable agents, which can even handle agents on behalf of the manager. A BAD may act as an intermediary device to increase system efficiency and performance. In this study, a device called "proxy", which can be installed as software on BAD devices, is proposed. The data measured by an agent can be sent to the proxy first, and subsequently be sent to the manager again. Agents and the manager are not aware of the proxy existence and work normally without the proxy. Furthermore, a new smart proxy and modified manager are proposed. The smart proxy acts as one agent handling measurement data from several agents, which can transmit a significant amount of data at once. The proxy and smart proxy maintain compatibility with existing devices that conform to the 20601 standard. The proposed schemes are verified and the complexities of devices are analyzed. The analysis shows no significant difference among the proxy, smart proxy, and manager. Simulations exhibit that the proposed schemes can improve the system performance.

중년여성의 신체 형태 특징 유형별 기성복 만족도 (A Study on the Satisfaction/Dissatifaction with the Fit of Ready-to-Wear Clothing Based on Middle Aged Women's Body Shapes)

  • 박우미;위은하
    • 한국의류산업학회지
    • /
    • 제5권3호
    • /
    • pp.235-243
    • /
    • 2003
  • This study is to figure out where the current satisfaction with ready-to-wear clothes based on middle-aged women's body shapes is at and to propose basic considerations in its production for coming up with a better sizing system to maximize customer's satisfaction. The data obtained from measurement and questionnaire by 126 middle- aged (35-59) women which were located in Gwangju. Followings are summary of this research, 1)The satisfaction level with lower -wear is relatively lower-wear than that of upper-wear in most parts of body. 2) The results by way of putting score show three different groups. Group 1 has characteristics of front body silhouette in the small ratio of shoulder width/bust width, shoulder width/waist width and big ratio of shoulder width/hip width. And Group 3 has characteristics of front silhouette, small ratio of hip girth/thigh girth. Group 2 has a standard shape. 3) The satisfaction level with lower-wear based on middle-aged women's body shapes shows slight difference. In this category, Group 2 has higher satisfaction level than that of Group 1, while Group 1 has better shape than Group 3. 4) The items of clothes which should be considered current less satisfaction on their size and pattern are skirt and pants. In the meantime, specific body parts for the same criteria are hip girth, thigh girth. And the 43.7% of middle-aged women who responded to this study requires improvement on the fit of lower-wear.

한국성인의 기관 길이 측정에 관한 연구 (A Study on the Measurement of the Normal Tracheal Length in Korea adults)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • 제28권8호
    • /
    • pp.766-771
    • /
    • 1995
  • The trachea is defined as the airway from the inferior border of the cricoid cartilage to the top of the carinal spur. This paper would confirm the normal tracheal length of Korean adults through the actual measurement using the fiberoptic bronchoscopy. The subjects of this study were 25 patients, 13 males and 12 females between the age of 20 to 69 without abnormality on the neck, trachea, mediastinum and lung pharenchyme on the preoperative chest X-ray, who received the operations from the period of July to September, 1994. For those patients who had heart diseases, the cardiothoracic ratio was below 50%. The measurement was performed on the patients with endotracheal intubation under the general anesthesia in supine and neutral position. The tracheal length was calculated by the difference between the length from the tip of the endotracheal tube [E-tube to carina and to the needle which was inserted into the E-tube at the lower border of the palpated cricoid cartilage, by inserting the broncoscopy through the E-tube. The result was as follow : 1 The measured tracheal length for men was 11.8 0.2 cm[mean standard deviation and women was 10.5 0.3 cm, and that was longer than this [p<0.01 . The average was 11.2 1.0 cm and the standard error was 0.20 cm. 2 According to the correlation between the tracheal length to weight, height[Ht , age, and body surface area[BSA respectively, the Ht [p=0.003 , age [p=0.055 , and the BSA[p=0.017 were significant, while weight was not [p=0.314 . 3 From the regression analysis of the tracheal length[T.L. to the Ht, Age, and the BSA which were significant, the following equation was derived.i Ht : T.L.= -1.29 + 0.076 x Ht [P=0.003 ii Age: T.L.= 10.04 + 0.028 x Age [P=0.055 iii BSA : T.L.= 5.60 + 3.48 x BSA [P=0.017 iv In multi-regression : T.L. = -4.15 + 0.034 x Age + 0.085 x Ht [P=0.0002]

  • PDF

Test-retest Reliability and Concurrent Validity of a Headphone and Necklace Posture Correction System Developed for Office Workers

  • Gyu-hyun Han;Chung-hwi Yi;Seo-hyun Kim;Su-bin Kim;One-bin Lim
    • 한국전문물리치료학회지
    • /
    • 제30권3호
    • /
    • pp.174-183
    • /
    • 2023
  • Background: Office workers experience neck or back pain due to poor posture, such as flexed head and forward head posture, during long-term sedentary work. Posture correction is used to reduce pain caused by poor posture and ensures proper alignment of the body. Several assistive devices have been developed to assist in maintaining an ideal posture; however, there are limitations in practical use due to vast size, unproven long-term effects or inconsistency of maintaining posture alignment. We developed a headphone and necklace posture correction system (HANPCS) for posture correction using an inertial measurement unit (IMU) sensor that provides visual or auditory feedback. Objects: To demonstrate the test-retest reliability and concurrent validity of neck and upper trunk flexion measurements using a HANPCS, compared with a three-dimensional motion analysis system (3DMAS). Methods: Twenty-nine participants were included in this study. The HANPCS was applied to each participant. The angle for each action was measured simultaneously using the HANPCS and 3DMAS. The data were analyzed using the intraclass correlation coefficient (ICC) = [3,3] with 95% confidence intervals (CIs). Results: The angular measurements of the HANPCS for neck and upper trunk flexions showed high intra- (ICC = 0.954-0.971) and inter-day (ICC = 0.865-0.937) values, standard error of measurement (SEM) values (1.05°-2.04°), and minimal detectable change (MDC) values (2.92°-5.65°). Also, the angular measurements between the HANPCS and 3DMAS had excellent ICC values (> 0.90) for all sessions, which indicates high concurrent validity. Conclusion: Our study demonstrates that the HANPCS is as accurate in measuring angle as the gold standard, 3DMAS. Therefore, the HANPCS is reliable and valid because of its angular measurement reliability and validity.