• 제목/요약/키워드: Standard Illuminance

검색결과 69건 처리시간 0.022초

An Experimental Study to Determine Proper Lighting Conditions in Powder Rooms

  • Kim, Hyun-Ji;Lim, Jang-Hyeon;Kim, Hoon
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.54-62
    • /
    • 2013
  • In this study, a mock powder room was installed with variable LED lighting environments in order to conduct the experiments. The experimental conditions include luminaire type, illuminance ratio, vertical illuminance and color temperatures. The evaluation methods used were the Semantic Differential Method and a subjective evaluation on activities through observation. The SD evaluation result factor analysis categorizes ideas into three factors: brightness, emotion, and glare. The vertical bracket or the combined luminaire (luminous panel+ Vertical bracket) has better brightness than luminous panel. A vertical illuminance of 500lx is not significantly difference as compared to 600lx, allowing 500lx to be considered standard. The emotional atmosphere is evaluated as being better at lower color temperature. The luminous panel is the best for reducing glare while the vertical bracket is the worst. The best conditions differ according to the illuminance ratio of the luminous panel and vertical bracket. In the subjective evaluation (satisfaction with lighting environment, suitability to activity) the combined luminaire and 4000K received the best evaluation.

축구 경기장의 조명타워 위치에 따른 조도분포 해석 (Illuminance Distribution Analysis by Lighting Tower Position of o Soccer Stadium)

  • 김길영;최홍규;최병숙
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2004
  • 오늘날 축구는 세계적인 주목을 받는 스포츠가 되었다. 특히, 2002 KOREA-JAPAN 월드컵은 한국에 대한 깊은 인상을 심어 주었다. 축구경기장의 조명시스템 설계에 있어서 가장 주요한 기술적 목적은 경기장의 어디에서나 최적의 분포를 나타내도록 하는 것이다. 이렇듯, FIFA는 경기장의 어디에서나 선수, 청중, 방송관계자등에게 일정한 수준의 조도를 제공할 수 있도록 규정하고 있다. 본 논문에서는 경기장의 조명타워의 위치선정에 따른 최적의 수평면 조도와 수직면 조도를 찾기 위한 알고리즘을 제시하였다. 본 논문에서는 Philip's Calculux 프로그램을 이용하여 조명타워의 위치에 따라 수평면 조도, 수직면 조도, 균제도, 글레어 등을 계산하였다.

조명원리를 기반으로 한 성당조도의 적정수준 적용분석 연구 (A Study on the application of appropriate level of illuminance to the Cathedral based on lighting principles)

  • 반상철
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.685-696
    • /
    • 2017
  • 성당의 공간이미지를 조성함에 있어, 시각을 통해 심성을 변화시키는 가장 중요한 요인은 빛이라고 할 수 있다. 그리고 공간의 깊이는 빛에 의한 음영에 의해 만들어진다. 미사와 같은 종교적 행사가 행해지는 장소에 있어서 음영에 의한 깊이의 변화와 위계설정은 집중도와 신비로움 또는 성스러움의 분위기를 확보하는 데에 중요한 계획조건이 된다고 할 수 있다. 따라서 빛이 가진 종교적 의미와 인간 감성에 미치는 영향은 매우 크다고 할 수 있으며, 이에 본 연구에서는 성당의 예배공간 조명계획에 대한 요소 중 '조도'를 그 중요요소로 보았다. 조도는 시각적 환경조성에서 미묘한 공간구성상의 차이를 통해 대상과 공간의 형태, 명료함을 부여함으로써 표현된다. 조명을 통해 공간분위기를 적정한 수준에서 관리하게 되고, 공간의 존재를 확인함에 조도의 역할은 필수적이라고 할 수 있을 것이다. 이에 따라, 관련 기준을 종합 분석하여 조도의 기준과 범위를 설정하고, 현대적인 디자인 적용이 시작되었다고 할 수 있는 80년대 이후 서울 강남지역에 건립된 성당들을 대상으로 조도와 관련된 요소들을 분석하고 각 성당의 전례공간과 회중석의 조도를 측정하여 이를 비교분석함으로써 적정수준의 적용여부를 검토확인하고 이를 추후 계획지침으로 활용하도록 제안하고자 하였다.

조명환경구역 구분을 위한 도심상업지역 보행자 도로의 조도분포 실태조사 (A Study on the Illuminance Distribution on the Pedestrian Road at the Central Business District for Classifying lighting Environments)

  • 이종식;박진철;김원우
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.1-13
    • /
    • 2009
  • 본 연구의 목적은 도심상업지역의 조도실태를 조사하여, CIE 조명환경구역 규정이 국내에 적용 가능한가를 검토하는 것이다. 현장조사를 통하여 도심상업지역 보행자 도로의 수평면 조도와 수직면 조도를 측정하였고, 조명환경에 대한 보행자의 만족도를 조사하기 위하여 설문을 실시하였다. 조사가 이루어진 장소는 모두 4곳으로 보행자 도로의 조명상태와 야간의 보행자 수가 각각 다른 곳이었다. 조도측정 결과 인구유동 및 조명상태에 따라 조도값이 차이를 보이고 있었으며, 설문조사 결과 보행자도로의 조도가 보행자의 조명환경 만족도에 영향을 미치는 것으로 나타났다. 마지막으로 CIE 조명환경구역의 조도 규정은 국내 도심상업지역에 적용할 수 있는 것으로 나타났다.

수장공간의 조도기준에 대한 연구 (A Study on the Illuminance Recommendations for a Museum Storage Area)

  • 김홍범
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.1-6
    • /
    • 2002
  • 박물관의 수장공간은 박물관의 가장 기초적인 기능을 수행하는 핵심 공간의 하나이다. 그럼에도 불구하고 일반적인 사무실이나 공장의 창고로 생각하여 소홀히 다루어지는 경우가 많다. 본 논문에서는 수장고의 조명계획시에 검토해야 할 요소를 살펴보고, 조명의 정량적인 기준인 조도에 대해서 검토하였다. 자료의 보존을 고려한다면 조도가 낮을수록 바람직하나, 자료관리를 감안한다면, 현재의 권장조도기준이 상대적으로 낮음을 알 수 있었다. 따라서 수장공간의 조도기준을 200[㏓]로 상향조정하고, 여타의 부속공간은 국부조명에 의해 조절하는 것이 타당하다.

대구·경북 지역 거실 조명 실태조사 (A Study on the Actual Conditions of Living Room Lighting in Daegu and Gyeongbuk Districts)

  • 조영미;안옥희;김현진
    • 한국주거학회논문집
    • /
    • 제23권3호
    • /
    • pp.13-20
    • /
    • 2012
  • This research study was conducted to determine the actual conditions of living room lighting in Daegu and Gyeongbuk districts. For this study, 112 households were surveyed. The results of this study are as follows: Firstly, fluorescent light was used as the general illumination of living rooms, and the ratio of not using local sources of illumination was high. Secondly, the standard illuminance was found to be 221. The illuminance was the value that satisfied the activities for togetherness and entertainment, but did not reach the illuminance necessary for other activities, such as reading, make-up, and sewing. In addition, the uniformity of brightness used as a measure of uniformity in examining the results was normal. Thirdly, both the brightness and the satisfaction of lighting in the living room space were indicated to be normal. In addition, in regard to housing lighting, 'stability', and 'brightness of lighting' were indicated as important considerations and 'brightness of lighting', 'shadow' and 'management of lighting' were indicated as problem areas.

주유소 조명 실태와 조도패턴 분석 (Survey on the Current Lighting Level at the Gas Stations and its Analysis on the Illuminance Pattern)

  • 주윤석;임종국;여인선
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.1-6
    • /
    • 1999
  • 이 논문에서는 주유소 조명시설의 실태를 조사하고 주유소의 각 영역별 조도를 측정하여 그 결과를 KS와 IESNA의 기준과 비교하고 주유소의 전체적인 조명패턴을 분석하였다. 주유지역에 있어서 조도는 KS에 제시된 값보다 상당히 높은 반면 IESNA의 기준보다는 대체로 낮음을 알 수 있었다. 그 외의 지역 또한 조도값에 있어서 서로 많은 차이가 발생함을 확인하였다. 이러한 결과로부터 주유소 조명시설의 적절한 유지·보수에 의해 불필요한 에너지 낭비를 줄일 수 있고, 이러한 점을 고려한 설계과정의 필요함을 알 수 있었다. 또한 KS규격에 있어서 다른 나라의 기준과 비교하여 각 영역별 작업특성을 고려한 철저한 평가와 기준설정이 이루어져야 하겠다.

  • PDF

창호일체형 광선반 시스템 채광성능 평가 (Daylighting Performance Evaluation of window Integrated Light Shelf System)

  • 정유근
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.41-46
    • /
    • 2007
  • The lightshelf system, a horizontal shading and light redirect device, should improve the visual environment by optimal light distributions and intense illumination levels of a interior. This study aims to evaluate the daylighting performance of window integrated lightshelf systems by computer simulations. For the study, the standard office plan is analyzed through the field surveys. And then, the various lightshelf types attached window systems are picked out from existed research results. The max, minimum and average illuminance levels of interiors and illuminance distributions are evaluated by Lightsacpe 3.2 programs based on the installing height, shape type and moving angle of lightshelfs. As results, it is suggested that the optimum lightshelf shapes are the height 1.8m and the width 600mm. Also, in mixed lightshelf, the outside width 600mm, inside width 400 are efficient on indoor daylighting performance.

조도 감지기를 이용한 절전형 간판 자동 전원 제어기 (The Energy-Efficient Automatic Power Controller of The Signboard using Illuminance Detector)

  • 라승탁;임송환;이승호
    • 전기전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.188-191
    • /
    • 2016
  • 본 논문에서는 조도 감지기를 이용하여 사용자가 설정한 조도량에 따라 점등되는 방식의 절전형 간판 자동 전원 제어기를 제안한다. 조도량 설정 방식은 사용자의 편리성을 감안하여 조도량 단위별 구간 분류 알고리즘을 통해 설정 과정이 누구나 쉽게 조작이 가능한 가변저항 방식을 제안한다. 자동 점등의 기준이 되는 조도량의 데이터는 조도 감지기가 측정한 조도량을 무선 통신을 통해 간판 자동 전원 제어기에 보내어 간판의 점등을 제어하게 된다. 본 논문에서 제안된 조도 감지기를 이용한 절전형 간판 자동 전원 제어기의 성능을 평가하기 위하여 공인 시험기관에서 외부의 빛이 모두 차단된 상태에서 시험한 결과, 각 구간별로 오차율이 ${\pm}3%$ 이하로 측정되어 우수한 성능을 나타내었다.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.