• 제목/요약/키워드: Standard Guide

검색결과 496건 처리시간 0.028초

Review for the Curriculum and License Exam of Physical Therapists in the United States

  • Choi, Chi-Whan;Jeong, Yeon-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • 제31권4호
    • /
    • pp.184-192
    • /
    • 2019
  • Purpose: This study was conducted to review the curriculum and license examination of physical therapists in the United States. Methods: The doctor of physical therapy (DPT) curriculum was evaluated by a review Course Work Tool version 6 (CWT6) data and current physical therapy licensure examination (National Physical Therapy Exam, NPTE) category in the United States. Results: The results indicated that they were required to meet the doctor of physical therapist degree based on 'Guide to Physical Therapist Practice' of American Physical Therapy Association (APTA). This includes general education in the areas of communications and humanities, physical science, biological science, social and behavioral science, and mathematics. A minimum of one course must be completed successfully in each area of general education. Moreover, there should be at least 68 didactic credits of professional education and 22 clinical education credits, which is a minimum of two full-time clinical internships with no less than 1050 hours in total, which were supervised by a physical therapist. Regarding the physical therapy licensure examination, National Physical Therapy Exam (NPTE, 2016) consisted of a physical therapy examination (26.5%), evaluation, differential diagnosis, baseline of prognosis (32.5%), intervention (28.5%), protection, responsibility, and research (6.5%) based on the 'Guide to Physical Therapist Practice'. Conclusion: Based on the study results provided above, it is considered a standard to meet domestic reality as the Guide to Physical Therapist Practice of APTA for South Korean physical therapists.

Analysis of revised regulatory guidance on electromagnetic interference qualification for nuclear safety

  • In Beom Ahn;Jaeyul Choo ;Jae Yoon Park ;Hyunchul Ku ;Kyeong-Sik Min
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.870-875
    • /
    • 2023
  • In this paper, we analyzed the revised guidance on electromagnetic (EM) interference qualification of Regulatory Guide 1.180 (Revision 2), which is published by the U.S. Nuclear Regulatory Commission for electromagnetic compatibility qualification for nuclear safety, by comparing it with that of the previous version. We confirmed that the test methods and the acceptance criteria of both CE101 and CE102 tests for conductive emission and RE102 test for radiating emission are changed in the recently revised Regulatory Guide 1.180 (Revision 2). Furthermore, we found that the revised Regulatory Guide 1.180 provides flexibility in the use of alternative methods for EM interference (EMI) qualification, in that a mix of the various base-standards is technically allowed. In addition, the primary revision of the updated Regulatory. Guide 1.180 is that MIL-STD-461G is to be adopted as the latest base-standard, instead of MIL-STD-461E. To evaluate the influence on EMI qualification for nuclear safety due to the endorsement of MIL-STD-461G, we thoroughly analyzed the modifications in the acceptance criteria and test methods for EMI qualification, and then validated the analyzed effect on the EMI qualification, which is caused by the revision of MIL-STD-461, by performing electromagnetic simulation for equipment under RE102 test.

광중합형 복합레진과 shade guide의 색차에 관한 연구 (A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides)

  • 임경민;이민호;송광엽
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.13-22
    • /
    • 2009
  • 심미적인 특성을 가진 복합레진은 전치부 수복용 재료로 많이 이용되고 있다. 복합레진 수복 시 만족스러운 결과를 얻기 위해서는 색조의 선택이 중요한 역할을 한다. 현재 대부분의 수복용 복합레진은 Vita Lumin 색조견본(shade guide)이나 각각의 회사에서 제공하는 색조견본을 사용하고 있으나, 색조 견본 사이의 색차와 수복물과 견본 사이에 색차가 예상되어 그 차이를 규명하여 임상적인 선택 시에 도움이 되고자 하였다. 4종의 광중합 복합레진(Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), $Esthet{\cdot}X$ ($E{\cdot}X$))과 A2와 A3의 색조 견본을 사용하였다. 각 재료마다 3개의 시편과 1개의 색조 견본을 제작하였다. Teflon 주형(깊이 1.35 mm, 직경 8 mm)에 각각의 복합레진을 채우고 응축한 후에 중합하여 젖은 사포로 연마하였다. 색조 견본을 연마용 stone과 고무를 이용하여 1.35 mm 두께로 연마하였다. 컴퓨터에 의해 조절되는 spectrophotometer(color i5, GretagMacbeth, USA)를 이용하여 시편과 색조견본의 색의 특성을 CIELAB coordinates ($L^*$, $a^*$, $b^*$)로 평가하였다. CIELAB 계측을 통하여 복합레진과 색조 견본의 색차(${\Delta}E^*ab$)를 비교 평가 하였다. 광원으로는 CIE standard D65를 사용하였다. 다음과 같은 결과를 얻었다. 1. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편의 $L^*$, $a^*$, $b^*$ 값 간에 유의할 만한 수준의 차이를 나타냈다(p<0.05). 2. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 3. 동일한 shade로 설계된 여러 제조회사의 복합레진과 제조회사에서 제공되는 shade guide 및 Vita Lumin shade guide 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 4. 임상에서 보다 나은 색 조화를 얻어 심미성을 향상시키기 위해서는 실제 수복물로 제작한 custom shade guide의 제작이 필요할 것으로 생각된다. 제조사에 의해 제공되는 색조 견본이나 Vita Lumin 색조 견본은 임상의에게 복합레진의 색조 선택 시에 정확한 기준을 제공하지는 않았고, 대부분의 제품에서 인지할 수 있는 색차가 있었다. 그러므로 보다 나은 색조 선택을 위해 수복용 레진으로 제작한 맞춤형 색조 견본을 사용하는 것을 추천한다.

한반도 남동부 미소지진을 이용한 응답스펙트럼 분석 (Analysis of Response Spectra using Microearthquakes of Southeastern Korean Peninsula)

  • 김연중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.27-32
    • /
    • 2000
  • Microearthquake records with magnitude 2.6~3.1 recorded in the southeastern part of the Korean peninsula during 1994~1998 are analyzed. Total of 42 records consisted of 12 events instrumented at 7 stations. The response spectra with the above data shows that the frequency range of the dominant response is about 10~25Hz and are compared with the standard response spectrum. The result implies that the characteristics of the microearthquake ground motion differ from those of standard response spectrum presented in US NRC Reg. Guide 1.60 especially at higher frequencies.

  • PDF

Effects of different split application and adapted fertilization cultivation for established GAP guide book in acorus graminens S.

  • Kim, Myeong Seok;An, Ho Sub;Kim, Gil Ja;Kim, Yong Soon;Choi, Jin Gyung;Park, Heung Gyu;Kim, Hyun Woo;Kim, Seong Il;Kim, Young Guk;Park, Chun Geun;Chang, Jae Gi
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.225-225
    • /
    • 2017
  • This study is to investigate the effect of split application and adapted fertilization application cultivation in stable medicinal herbs production of Acorus graminens S. And it accomplished one's purpose to GAP guide manual established standard method of cultivation technology, contribute to the enlargement of farm's income. Method of fertilization application were conducted under five condition compose to standard application(N-P-K-Compost: fermented mixed oil cake fertilizer applied at $4-2-6-300kg.10a^{-1}$, twofold application(N-P-K-Compost applied at $8-4-12-600kg.10a^{-1}$) cultivation. Compost (fermented mixed oil cake fertilizer) and fused phosphate applied at 100% of basal fertilizer in April 14. The split application level of standard application and twofold application(N-K) applied at 100%, 50%, 40% of basal fertilizer in April 14, 50% and 40% of top dressing were three times application (N-K) in June 1, July 15, August 15, 25% and 20% respectively. Transplanting with Naju varieties in May 12 by growing pot seedling for 40 days in 2015. Planting density were spaced 30 cm apart in rows 30 cm apart with black vinyl mulching on open cultivation. Plot design randomized block 3 repetition. Therefore, growth characteristics by 50% and 40% of top dressing were three times application (N-K) compared to standard application and twofold application (N-K) applied at 100% basal fertilizer, aerial part as a result were so many such amount of growth as number of leaf per plant, etc., Length of diameter and main root of subterranean part growth increment rising highest. Dried roots yields treated standard fertilizer 100% application($250kg.10a^{-1}$) compared to 100% from twofold application (N-K) applied at 50% basal fertilizer, 50% and 40% of top dressing were three times application increased by 16%, 20%. respectively.

  • PDF

Adjustable Ghajar Guide Technique for Accurate Placement of Ventricular Catheters : A Pilot Study

  • Yoon, Sang-Youl;Kwak, Youngseok;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권5호
    • /
    • pp.604-609
    • /
    • 2017
  • Objective : An adjustable Ghajar guide is presented to improve the accuracy of the original Ghajar guide technique. The accuracy of the adjustable Ghajar guide technique is also investigated. Methods : The coronal adjustment angle from the orthogonal catheter trajectory at Kocher's point is determined based on coronal head images using an electronic picture archiving and communication system. For the adjustable Ghajar guide, a protractor is mounted on a C-shaped basal plate that is placed in contact with the margin of a burrhole, keeping the central $0^{\circ}$ line of the protractor orthogonal to the calvarial surface. A catheter guide, which is moved along the protractor and fixed at the pre-determined adjustment angle, is then used to guide the ventricular catheter into the frontal horn adjacent to the foramen of Monro. The adjustable Ghajar guide technique was applied to 20 patients, while a freehand technique based on the surface anatomy of the head was applied to another 47 patients. The accuracy of the ventricular catheter placement was then evaluated using postoperative computed tomography scans. Results : For the adjustable Ghajar guide technique (AGT) patients, the bicaudate index ranged from 0.23 to 0.33 ($mean{\pm}standard$ deviation [SD] : $0.27{\pm}0.03$) and the adjustment angle ranged from $0^{\circ}$ to $10^{\circ}$ ($mean{\pm}SD:5.2^{\circ}{\pm}3.2^{\circ}$). All the AGT patients experienced successful cerebrospinal fluid diversion with only one pass of the catheter. Optimal placement of the ventricular catheter in the ipsilateral frontal horn approximating the foramen of Monro (grade 1) was achieved in 19 patients (95.0%), while a suboptimal trajectory into a lateral corner of the frontal horn passing along a lateral wall of the frontal horn (grade 3) occurred in 1 patient (5.0%). Thus, the AGT patients experienced a significantly higher incidence of optimal catheter placement than the freehand catheterized patients (95.0% vs. 68.3%, p=0.024). Moreover, none of the AGT patients experienced any tract hemorrhages along the catheter or procedure-related complications. Conclusion : The proposed adjustable Ghajar guide technique, using angular adjustment in the coronal plane from the orthogonal trajectory at Kocher's point, facilitates accurate freehand placement of a ventricular catheter for hydrocephalic patients.

모듈형 퍼스널 로봇의 소프트웨어 아키택처 개발 (Development of Software Architecture for Modular Personal Robot)

  • 김홍석;양광웅;최무성;원대희;이호길
    • 제어로봇시스템학회논문지
    • /
    • 제10권12호
    • /
    • pp.1264-1270
    • /
    • 2004
  • In this paper, a standard robot design methodology is suggested and a software architecture for modular robot is introduced. The robot is modularized by several functions, and the module is produced according to a standard proposal. Each module requires standard interface for communicate in distributed environments. Software architecture was developed to support distributed component environment, and application development support tools are developed for user convenience. Many robot softwares are developed in a library form so that, they are being used widely robot application software development. Also a device driver was developed for the mostly used sensor and actuator. It is verified that the modular robot can be applied in various fields through guide, errand and guard scenario.

보전성 경영 프로그램 개발을 위한 지침 (Guide-line for Developing a Maintainability Program)

  • 이낙영;김종걸;권영일;홍연웅;전영록;나명환
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2001년도 정기학술대회
    • /
    • pp.269-269
    • /
    • 2001
  • Maintainability refers to the ease with which maintenance work can be done. It involves the process of ensuring that products can be easily and safely maintained and that the maintenance support requirement is minimized. When a product has a reasonably long life, the cost of operation and support during that life can greatly exceed the initial capital cost. The value to the customer of optimizing maintainability should be evident. Some effort and expense applied to achieving a product which can be easily and cheaply maintained will make very significant savings in the life cycle costs. In this paper, the International Standard IEC 60300-3-10, which is the application guide for maintainability, is considered. This standard can be used to implement a maintainability program covering the initiation, development and in-service phases of a product. It provides guidance on how the maintenance aspects of the tasks should be considered in order to achieve optimum maintainability. The elements of a maintainability program, which are maintenance policy and concept, maintainability studies, project management, design for maintainability, analysis and prediction methods, maintenance verification and validation, analysis of life cycle cost, maintenance support planning, and collection and analysis of maintenance data, are fully discussed in this paper.

  • PDF

수중소음 관리 기준 설정을 위한 소고 (A Study on the Establishment of Management Criteria for Underwater Noise)

  • 임대규;신영철;전양배
    • 화약ㆍ발파
    • /
    • 제28권2호
    • /
    • pp.119-132
    • /
    • 2010
  • 각종 토목공사가 수행됨에 유발되는 소음 및 진동에 관한 민원사례가 증가하고 있다. 일반적으로 육상부보안물건에 대한 관리기준과 피해 발생시 분쟁을 해결하는 객관적 기준자료는 다수 확보된 상태이다. 그러나 수중 소음에 관한 객관적 자료나 기준은 부족한 상태이다. 수중 생태의 환경 검토는 국외의 경우 수중소음계를 이용한 수중소음계측 방식 및 계측 결과값에 대한 항목(최대소음레벨, 실효치, 노출소음레벨)별 관리기준을 제시하고 있으며, 청각역치 연구 결과를 토대로 관리기준을 제시하고 있다. 그러나 국내에서는 수중생태에 관한 연구자료 및 피해정도를 판단할 수 있는 관리기준의 설정이 미흡한 상태이다. 따라서 본 연구는 수중 소음 측정 장비를 활용한 합리적인 수중소음 관리기준 설정을 위한 방향을 모색하고자 한다.

GC/MS를 이용한 혈액 중 유기인제류 농약의 동시 분석에 관한 방법의 유효화 (Method Validation for the Simultaneous Analysis of Organophosphorous Pesticides in Blood by GC/MS)

  • 박미정;양자열;김기욱;박유신;정희선;이상기
    • Environmental Analysis Health and Toxicology
    • /
    • 제20권4호통권51호
    • /
    • pp.297-302
    • /
    • 2005
  • The purpose of this study was to provide the standard method for the analysis of organophosphorous pesticides such as chlorpyrifos, diazinon, malathion and parathion in blood. We performed method validation for these pesticides in blood according to EURACHEM (A focus For Analytical Chemistry in Europe) guide. For the analysis of the pesticides, we used solid-phase extraction ,column (Waters Oasis $HLB^{(R)}$. After the extraction, the supernatants were evaporated to dryness under the nitrogen stream. They were analyzed by gas chromatography/mass spectrometry (GC/MS) after reconstituting with ethanol. Terbufos was used as an internal standard. To validate this method, we performed verification procedures with the following parameters: selectivity, linearity of calibration, accuracy, precision, limit of detection and quantification. Validation data according to Eurachem guide were adequate for our purpose for the analysis of chlorpyrifos, diazinon, malathion and parathion in blood.