• Title/Summary/Keyword: Standard Density of point

Search Result 70, Processing Time 0.033 seconds

Distance between the Distributions of the P-value and the Lower Bound of the Posterior Probability

  • Oh, Hyun-Sook
    • Communications for Statistical Applications and Methods
    • /
    • v.6 no.1
    • /
    • pp.237-249
    • /
    • 1999
  • It has been issued that the irreconcilability of the classical test for a point null and standard Bayesian formulation for testing such a point null. The infimum of the posterior probability of the null hypothesis is used as measure of evidence against the null hypothesis in Bayesian approach; here the infimum is over the family of priors on the alternative hypotheses which includes all density that are a priori reasonable. For iid observations from a multivariate normal distribution in $\textit{p}$ dimensions with an unknown mean and a covariance matrix propotional to the Identity we consider the difference and the Wolfowitz distance of the distributions of the P-value and the lower bound of the posterior probability over the family of all normal priors. The Wolfowitz distance is interpreted as the average difference of the quantiles of the two distrbutions.

  • PDF

Weld Defect Formation Phenomena during High Frequency Electric Resistance Welding

  • Choi, Jae-Ho;Chang, Young-Seup;Kim, Yong-Seog
    • Journal of Welding and Joining
    • /
    • v.19 no.3
    • /
    • pp.267-273
    • /
    • 2001
  • In this study, welding phenomena involved in formation of penetrators during high frequency electric resistance welding were investigated. High speed cinematography of the process revealer that a molten bridge between neighboring skelp edges forms at apex point and travels along narrow gap toward to welding point at a speed ranging from 100 to 400 m/min. The bridge while moving along the narrow gap swept away oxide containing molten metal from the gap, providing oxide-free surface for a forge-welding at upsetting stand frequency of the budge formation, travel distance and speed of the bridge were affected by the heat input rate into strip. The travel distance and its standard deviation were found to have a strong relationship with the weld defect density. Based on the observation, a new mechanism of the penetrator formation during HF ERW process is proposed.

  • PDF

A Study of the Printability Coefficients on the Newspaper (I) - A Study on the printed density and print through in the maximum transfer point - (신문용지의 인쇄적성 예수에 관한 연구 (제1보) - 최대전이점에서 인쇄 색농도 및 뒤비침 -)

  • Ha Young-Baeck;Kim Chang-Keun;Oh Sung-Sang;Youn Jong-Tae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.1 s.113
    • /
    • pp.27-33
    • /
    • 2006
  • Newsprint is quantitatively the most important printing paper. The demands for its printability are continuously increasing. It is well known that the relationship between the physically tested paper properties and newspaper printability is unsatisfactory. In order to improve the printing quality of Korean newsprint, the printability coefficients such as maximum ink requirement(Ymax), print through were investigated. Kinds of newspapers and black printing ink were tested by IGT printability tester. Experiment condition of IGT printability tester was 14 steps between $0.2{\sim}2.8g/m^2$ of ink requirement, printing pressure was 200 N and printing velocity was 1 m/sec. The properties of newspaper samples (basis weight, bulk density, roughness, smoothness, porosity, i. e.) were examined in accordance with KS and TAPPI standard testing methods. The result of this study are respected for usefulness printing quality management of Korean newsprint.

Development of Drought Index based on Streamflow for Monitoring Hydrological Drought (수문학적 가뭄감시를 위한 하천유량 기반 가뭄지수 개발)

  • Yoo, Jiyoung;Kim, Tae-Woong;Kim, Jeong-Yup;Moon, Jang-Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.669-680
    • /
    • 2017
  • This study evaluated the consistency of the standard flow to forecast low-flow based on various drought indices. The data used in this study were streamflow data at the Gurye2 station located in the Seomjin River and the Angang station located in the Hyeongsan River, as well as rainfall data of nearby weather stations (Namwon and Pohang). Using streamflow data, the streamflow accumulation drought index (SADI) was developed in this study to represent the hydrological drought condition. For SADI calculations, the threshold of drought was determined by a Change-Point analysis of the flow pattern and a reduction factor was estimated based on the kernel density function. Standardized runoff index (SRI) and standardized precipitation index (SPI) were also calculated to compared with the SADI. SRI and SPI were calculated for the 30-, 90-, 180-, and 270-day period and then an ROC curve analysis was performed to determine the appropriate time-period which has the highest consistency with the standard flow. The result of ROC curve analysis indicated that for the Seomjin River-Gurye2 station SADI_C3, SRI30, SADI_C1, SADI_C2, and SPI90 were confirmed in oder of having high consistency with standard flow under the attention stage and for the Hyeongsan River-Angang station, SADI_C3, SADI_C1, SPI270, SRI30, and SADI_C2 have order of high consistency with standard flow under the attention stage.

Introduction on the Contamination Design Standard(Revision Proposal) of 345kV/154kV Transmission System in KEPCO (345kV/154kV 직접접지계 송전설비의 내오손 설계기준(안) 해설)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Min, B.W.;Lee, O.B.;Shin, T.W.;Park, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.262-264
    • /
    • 2002
  • This paper shows the design standard of KEPCO on the contamination design for 345 kV and 154 kV transmission tower. Up to now, because the design standard of KEPCO on the insulation design contains 154 kV transmission system only, we had investigated the 343 kV system for the revision of design standard, with respect to the contamination design, we have used the same design philosophy which were adopted to the 765 kV transmission tower. In order to determine the number of insulator discs, we had investigated the withstand voltage of discs according to the level of ESDD(Equivalent Salt Deposit Density) and kinds of disc types. The TOV(Power Frequency Temporary Overvoltage) were estimated by EMTP(Electromagnetic Transient Program) for both 154 kV and 345 kV transmission system. The overvoltage level was appeared 1.35 p.u. between phase to ground for both 154 kV and 345 kV transmission system, but finally this factor was not applied to the design standard considering current design standard and economic point of view. With regard to classification of contamination area of 345 kV transmission system, we added the clean area which was not specified in the current design practise.

  • PDF

Quincunx Sampling Method for Performance Improvement of 2D High-Density Wavelet Transformation (2차원 고밀도 이산 웨이브렛 변환의 성능 향상을 위한 Quincunx 표본화 기법)

  • Lim, Joong-Hee;Shin, Jong-Hong;Jee, Inn-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.179-191
    • /
    • 2013
  • The quincunx lattice is a non-separable sampling method in image processing. It treats the different directions more homogeneously and good frequency property than the separable two dimensional schemes. The high density discrete wavelet transformation is one that expands an N point signal to M transform coefficients with M > N. In two dimensions, this transform outperforms the standard discrete wavelet transformation in terms of shift-invariant. Although the transformation utilizes more wavelets, sampling rates are high costs. This paper proposed the high density discrete wavelet transform using quincunx sampling, which is a discrete wavelet transformation that combines the high density discrete transformation and non-separable processing method, each of which has its own characteristics and advantages. Proposed wavelet transformation can service good performance in image processing fields.

DBSCAN-based Energy-Efficient Algorithm for Base Station Mode Control (에너지 효율성 향상을 위한 DBSCAN 기반 기지국 모드 제어 알고리즘)

  • Lee, Howon;Lee, Wonseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1644-1649
    • /
    • 2019
  • With the rapid development of mobile communication systems, various mobile convergence services are appearing and data traffic is exploding accordingly. Because the number of base stations to support these surging devices is also increasing, from a network provider's point of view, reducing energy consumption through these mobile communication networks is one of the most important issues. Therefore, in this paper, we apply the DBSCAN (density-based spatial clustering of applications with noise) algorithm, one of the representative user-density based clustering algorithms, in order to extract the dense area with user density and apply the thinning process to each extracted sub-network to efficiently control the mode of the base stations. Extensive simulations show that the proposed algorithm has better performance results than the conventional algorithms with respect to area throughput and energy efficiency.

A Comparison Study on the Method of Pollution Evaluation of Water Quality in the Stream (하천 수질의 오염도평가 방법의 비교 연구)

  • Lee, Ho-Beom;Lee, Jung-Ki;Shin, Dae-Yewn
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.398-403
    • /
    • 2005
  • This study is undertaken to find the optimal method to make the decision on the degree of water pollution by comparison of K-WQI, KOE-WQI that is made for index with the water quality index and water quality environment standard of the Frame Act on Environment Policy as the result of survey for water quality reality on the major point of the Yeongsan river from 2002 to 2004. The water quality of major rivers has some differences depending on seasons. however, under the water quality standard by the $BOD_5$ density, most of rivers displayed the water quality level of $II{\sim}III$ grading, and on K-WQI that is classified by indexing for 10 categories of pH, DO, $BOD_5,\;COD,\;SS,\;T-N,\;NH_3-N,\;NO_{3^-}$ N, T-P, and E-Coli and classified into 5 groups from 100 points to 40 points, they displayed the score distribution of the first grade in water quality for $85{\sim}100$ points to the second grade in water quality for $70{\sim}84$ points. On KOE-WQI that is classified by indexing for 5 categories of pH, DO, $BOD_5$, COD and T-coli and classified into 5 groups from 90 points or above for outstanding and 29 points or below for very bad, and the water quality distribution is made ranged from the first grade in water quality for 90 points or more to the third grade in water quality for $69{\sim}50$ points. In addition, for the contribution of the water quality decline, the Environmental standard has significant dependency on the $BOD_5$ density, with K-WQI contributing in various water quality decline depending on the environment around the river area of $BOD_5,\;T-N,\;NH_3-N,\;NO_3-N,\;T-P$, and E-Coli, and KOE-WQI acting os the factor contributing to lower the water quality decline by $BOD_5$, COD, and T-coli. As such, the current water quality environment standard has high dependency on $BOD_5$ and KOE-WQI excludes some nitrogen and phosphorus that considers the river environment that the grade in water quality is set by some category, and K-WQI reflected well of the ecology environment of rivers with the diversity of the assessment factor as well as to have the low dependency of specific factor to be objective.

FRACTURE TOUGHNESS CHARACTERISTICS IN HIGH ENERGY DENSITY BEAM WELDED JOINT OF HIGH TENSILE STEELS

  • Ro, Chan-Seung;Yamada, Tomoaki;Mochizuki, Masahito;Ishikawa, Nobuyuki;Bang, Han-Sur;Toyoda, Masao
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.583-588
    • /
    • 2002
  • The purpose of the study is to evaluate fracture toughness on the Laser and the electron beam welded joints of high tensile steels (HT500, HT550, HT650) by using 3-point bend CTOD and Charpy impact test. WM (weld metal) CTOD tests have been carried out using two kinds of CTOD specimen, the Laser beam welding (108mm length, and 24mm width, and 12mm thickness) and the electron beam welding (l71mm length, and 38mm width, and 19mm thickness). WM Charpy impact specimen is a standard V-notch type, and the temperature of the experiment is changed from -45 to 20 degree of centigrade. FE-analysis is also performed in order to investigate the effect of stress-strain fields on fracture characteristics. Results of the standard V-notch Charpy test are influenced by strength mis-match effect and the absorbed energy vE depends on crack path, and The transition temperature of Laser beam welded joints is more higher than that of electron beam welded joints. Results of the 3-point bend test give low critical CTOD and the crack path is in the weld metal of al specimens. These results indicate fracture toughness characteristics of the welded joints and transition temperature of HT500 are similar both a Laser beam welded joint and an electron beam welded joint. But the fracture toughness and the transition temperature of the electron beam welded joints of HT550 and HT650 are higher than those o the Laser beam welded joints.

  • PDF

Appropriate image quality management method of bone mineral density measurement (골밀도 측정의 올바른 질 관리방법)

  • Kim, Ho-Sung;Dong, Kyung-Rae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1141-1149
    • /
    • 2009
  • In Bone Mineral Density(BMD) measurements, accuracy and precision must be superior in order to know the small changes in bone mineral density and actual biological changes. Therefore the purpose of this study is to increase the reliability of bone mineral density inspection through appropriate management of image quality from machines and inspectors. For the machine management method, the recommended phantom from each bone mineral density machine manufacturer was used to take 10~25 measurements to determine the standard amount and permitted limit. On each inspection day, measurements were taken everyday or at least three times per week to verify the whether or not change existed in the amount of actual bone mineral density. Also evaluations following Shewhart control chart and CUSUM control chart rules were made for the bone mineral density figures from the phantoms used for measurements. Various forms of management became necessary for machine installation and movement. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. There were two measurement methods followed: patients were either measured twice with 30 measurements or three times with 15 measurements. An important point to make regarding measurements is that after the first inspection and any other inspection following, the patient was required to come off the inspection table completely and then get back on for any further measurements. With a 95% confidence level, the precision error produced from the measurement bone mineral figures produced a precision error of 2.77 times the minimum of the biological bone mineral density change (Least significant change: LSC). In order to assure reliability in inspection, there needs to be good oversight of machine management and measurer for machine operation and inspection error. Accuracy error in machines needs to be reduced to under 1% for scientific development in bone mineral density machines.

  • PDF