• Title/Summary/Keyword: Standard DC

Search Result 321, Processing Time 0.025 seconds

A Study of Power Conversion System for Energy Harvester Using a Piezoelectric Materials (압전소자를 이용한 에너지 하베스터용 전력변환장치 연구)

  • An, Hyunsung;Kim, Young-Cheol;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1059-1065
    • /
    • 2017
  • In this paper, the energy harvester with a piezoelectric materials is modeled as the electric equivalent circuit, and performances of a standard DC method and a Parallel-SSHI method are verified through experiment under variable force and load conditions. Piezoelectric generator consists of mass, damper and spring constant, and it is modeled by electrical equivalent circuit with RLC components. Standard DC and Parallel-SSHI are used as power conversion methods, and standard DC consists of full-bridge rectifier and smoothing capacitor. Parallel-SSHI method is composed of L-C resonant circuit, zero-crossing detector and full-bridge rectifier. In case of simulation under $100k{\Omega}$ load condition, the harvested power is $500{\mu}W$ in Standard DC and $670{\mu}W$ in Parallel-SSHI, respectively. In experiment, the harvested power under $100k{\Omega}$ load condition is $420{\mu}W$ in standard DC and $602{\mu}W$ in Parallel-SSHI. Harvested power of Parallel-SSHI is improved by approximately 40% more than that of standard DC method.

A Study of Energy Harvester Using a Parallel SSHI Method (병렬 SSHI 기법을 이용한 에너지 하베스터 연구)

  • An, Hyunsung;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.463-464
    • /
    • 2016
  • 본 논문은 압전소자 발전기를 이용하여 하베스팅 에너지 발전량을 증대시키기 위한 에너지 하베스팅 방법을 제안하였다. 기존의 풀브리지 정류기만을 이용한 standard DC 방법에 압전소자와 병렬로 공진을 위한 인덕터와 MOSFET를 연결하여 parallel SSHI 회로를 구성하였으며, 또한 변위센서와 비교기를 통해 스위치 시점을 결정한다. 시뮬레이션 분석을 위해 압전발전기를 등가회로로 모델링하였으며, standard DC방법과 parallel SSHI 방법의 성능을 비교하여 parallel SSHI 방법이 standard DC 방법보다 약 13%의 전력이 증대된 것을 확인 하였다.

  • PDF

Design and Development of 30W Military Grade DC-DC Converter for Guided Weapon and Aircraft (유도무기 및 항공기 탑재장비용 30W급 군사용 DC-DC 변환장치 개발)

  • Park, Sang-Min;Joo, Dong-Myoung;Chae, Soo-Yong;Kim, Hyung-Jung;Lee, Byoung-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1341-1350
    • /
    • 2017
  • In this paper, a high reliability 30W DC-DC converter is designed considering military standard (MIL-STD) for military applications such as guided weapon and aircraft. The performances and specifications of conventional military grade DC-DC converter are practically analyzed. The requirements for military grade DC-DC converter are established in consideration of MIL-STD and analysis results of conventional product. Two isolated DC-DC converter, forward and fly-back converter, are designed and compared to determine topology. From experimental results under various operating conditions, the forward topology satisfied performances and specifications of MIL-STD for military DC-DC converter.

Development of an Input Impedance Evaluation of the AC-DC Transfer Standard for Low Level AC Voltage Standard (교류 저전압 표준용 교류-직류 변환기의 입력임피던스 평가기술 개발)

  • Kwon, Sung-Won;Jung, Jae-Kap;Lee, Sang-Hwa;Kim, Myung-Soo;Kim, Han-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.229-234
    • /
    • 2008
  • An AC-DC transfer standard(TS) is used for the AC voltage standard in the range of 2 mV to 1000 V below 1 MHz. Micro-potentiometer(${\mu}Pot$) is used to evaluate the ac-dc transfer difference(ADD) of the TS below 200 mV range. The ADD of the TS were changed by the loading effect caused from the input impedance change of the TS depend on frequency. An input impedance evaluation technique of the TS using ${\mu}Pot$ has been developed.

Automated Black-Box Test Case Generation for MC/DC with SAT (SAT를 이용한 MC/DC 블랙박스 테스트 케이스 자동 생성)

  • Chung, In-Sang
    • The KIPS Transactions:PartD
    • /
    • v.16D no.6
    • /
    • pp.911-920
    • /
    • 2009
  • Airbone software must comply the DO-178B standard in order to be certified by the FAA. The standard requires the unit testing of safety-critical software to meet the coverage criterion called MC/DC(Modified Condition/Decision Coverage). Although MC/DC is known to be effective in finding errors related to safety, it is also true that generating test cases which satisfy the MC/DC criterion is not easy. This paper presents a tool named MD-SAT which generates MC/DC test cases with SAT(SATisfiability) technology. It can be employed for generating diverse test cases in tools implementing various testing techniques including decision table based test, cause-effect graphing, and state-based test.

Protective Insulation Monitoring Device in IT Earth Systems (IT접지방식의 보호를 위한 활선절연저항 감시기)

  • Kim, Yong-Jung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.209-213
    • /
    • 2015
  • With the increasing popularity of renewable generation systems and the advancement of power electronics, DC distribution systems have recently received considerable research attention. DC distribution has numerous advantages, including reliability, power quality, and efficiency. Owing to these advantages, DC distribution has been applied to data centers and power quality-sensitive electronic load conditions. Because grounding electrodes in DC are much more susceptible to corrosion than in AC, the IT system defined in IEC Standard 60364 may be a good candidate for an earthing method for DC distribution systems. In addition, IEC Standard 61557 specifies the requirements for insulation monitoring devices (IMD) for protection of the IT system, which continuously monitors the insulation resistances between the power lines and the earth. This paper discusses the development and evaluation of IMD to promote the reliability of distribution systems and increase safety of humans and facilities.

400mA Current-Mode DC-DC Converter for Mobile Multimedia Application (휴대용 멀티미디어 기기를 위한 400mA급 전류 방식 DC-DC 컨버터)

  • Heo, Dong-Hun;Nam, Hyun-Seok;Lee, Min-Woo;Ahn, Young-Kook;Roh, Jeong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.8
    • /
    • pp.24-31
    • /
    • 2008
  • Power converters are becoming an essential block in modem mobile multimedia application. This paper presents a high performance DC-DC buck converter for mobile applications. Controller of DC-DC buck converter is designed by current-mode control method. An current-mode DC-DC converter is implemented in a standard $0.18{\mu}m$ CMOS process, and the overall die size was $1.2mm^2$. The peak efficiency was 86 % with a switching frequency of $1\sim1.5MHz$ and a maximum load current of 400mA.

Development of Analysis Model for Metro Railway DC Electric Power System (도시철도 DC 급전시스템 해석 모델 개발)

  • Cha, Jun-Min;Kim, Hyung-Chul
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1411-1417
    • /
    • 2006
  • The DC electric power system is the most important power source in a metro railway system. As metro railway system is expanded recently, the importance of DC electric power system is emphasized. Furthermore, the study for systemization and standardization of design and operation technique in DC electric power system is undergoing nowadays. For these studies, the development of standard analysis model for metro railway electric power system is required. In this paper, a standard analysis model for metro railway electric power system which is using PSCAD/EMTDC program is developed. The developed model is explained and the validity is shown by using the case studies.

  • PDF

An 18-Pulse Full-Wave AC-DC Converter for Power Quality Improvement

  • Singh, Bhim;Gairola, Sanjay
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.109-120
    • /
    • 2008
  • In this paper, a novel delta/double-fork transformer based 18-pulse full-wave AC-DC converter is designed, modeled, simulated and developed to feed isolated DC varying loads. The proposed AC-DC converter is used for low voltage and large current DC loads in applications such as electrowinning, where isolation is required mainly for stepping down the supply voltage. The proposed converter improves power quality at AC mains and meets IEEE-519 standard requirements at varying loads.

A STUDY ON BONE STRENGTH AND THE DEGREE OF CONVERSION OF DENTIN BONDING AGENTS (수종 상아질 접착제의 결합강도와 중합률에 관한 연구)

  • Kim, Byung-Hyun;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.68-93
    • /
    • 1998
  • The physical properties of polymer are greatly influenced by the extent to which a resin cures. The presence of un reacted monomer can, have a plasticizing effect on the polymer, thereby altering the physical and mechanical properties of dentin bonding agent (DBA). If the DBA does not polymerize sufficiently, it will leave a weak bonding layer and lead to lower bond strength. The purpose of this study was to evaluate the shear bond strengths(SBS) and the degree of conversion (DC) of 4 commercialy avilable dentin bonding systems which are composed of 2 multi-bottle systems [Scotchbond Multi-Purpose (SMP), AeliteBond(AB)] and 2 onebottle systems [SingleBond(SB), One-Step(OS)]. For shear bond strength measurement, labial surfaces of freshly extracted bovine incisors were ground with # 600 grit SiC paper to expose dentin. Four different groups of samples were formed, with 10 samples. being made for each of the 4 commercial DBA in each group according to the curing sequences of DBA and overlayer thickness of composites: Group I (standard cure and 1mm thick composites) : The DBA was light cured and the composites of 1mm thickness was applied ; Group II (standard cure and 2mm thick composites) : The DBA was light cured and the composites of 2mm thickness was applied; Group III (simultaneous cure and 1mm thick composites) : The DBA was not light-cured and simultaneously cured with composites of 1mm thickness; Group N (simultaneous cure and 2mm thick composites) : The DBA was. not light-cured and simultaneously cured with composites of 2mm thickness. The SBS was measured immediately after the composites was bonded to the bovine dentin using an Instron machine. The DC of the DBA was examined in a thin film under simulated conditions of the experimental groups according to the curing sequences and overlayer thickness of composites in the SBS test. using a Fourier transform Infrared(FTIR) spectrometer. The following results were obtained from SBS tests and DC measurements 1. In SBS tests, the multi-bottle DBA(SMP, AB) had a generally higher bond strength values than the one bottle DBA(SB, OS). In DC measurements, the one bottle DBA(SB, OS) had a significantly higher DC than the multi-bottle DBA(SMP, AB). 2. In all DBAs except OS, there was no significant difference between the bond strength of group I (standard cure and 1mm thick composites) and that of group III (simultaneous cure and 1mm thick composites). SMP, SB in Group I had a significantly higher DC than those in group III, but AB, OS in group I had a significantly lower DC than those in group III 3. All DBAs in Goup II (standard cure and 2mm thick composites) had significantly higher bond strength and DC than those in Group N (simultaneous cure and 2mm thick composites). 4. In all DBAs, there was no significantly different SBS and DC between Group I and Group II, but all DBAs in Group III had significantly higher SBS and DC than those in Group IV.

  • PDF