• Title/Summary/Keyword: Standard C/T

Search Result 695, Processing Time 0.027 seconds

Determination of Chaboche Cyclic Combined Hardening Model for Cracked Component Analysis Using Tensile and Cyclic C(T) Test Data (표준 인장시험과 반복하중 C(T) 시험을 이용한 균열해석에서의 Chaboche 복합경화 모델 결정법)

  • Hwang, Jin Ha;Kim, Hune Tae;Ryu, Ho Wan;Kim, Yun Jae;Kim, Jin Weon;Kweon, Hyeong Do
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.2
    • /
    • pp.31-39
    • /
    • 2019
  • Cracked component analysis is needed for structural integrity analysis under seismic loading. Under large amplitude cyclic loading conditions, the change in material properties can be complex, depending on the magnitude of plastic strain. Therefore the cracked component analysis under cyclic loading should consider appropriate cyclic hardening model. This study introduces a procedure for determining an appropriate cyclic hardening model for cracked component analysis. The test material was nuclear-grade TP316 stainless steel. The material cyclic hardening was simulated using the Chaboche combined hardening model. The kinematic hardening model was determined from standard tensile test to cover the high and wide strain range. The isotropic hardening model was determined by simulating C(T) test under cyclic loading using ABAQUS debonding analysis. The suitability of the material hardening model was verified by comparing load-displacement curves of cyclic C(T) tests under different load ratios.

Survey on 3GPP Core Network Simulator (3GPP 코어 네트워크 시뮬레이터 기술 동향)

  • S.J. Shin;D.Y. Lee;T.H. Na;C.S. Lee;T.Y. Kim
    • Electronics and Telecommunications Trends
    • /
    • v.39 no.2
    • /
    • pp.77-92
    • /
    • 2024
  • The 3GPP (3rd Generation Partnership Project) mobile communication standard has emerged as a leading standard in the market over the past 20 years, driving continuous development in protocol stacks and libraries that support the standard within simulation software for communication network research. We summarize and analyze seven communication network simulators that support the 3GPP standard specifications related to core network technologies. Through comparisons, we aim to offer valuable insights for researchers and engineers engaged into research and development related to mobile communication networks based on 3GPP standards. Our findings can provide assistance for making informed decisions on simulator selection.

PARAMETER SPACE FOR EIGENMAPS OF FLAT 3-TORI INTO SPHERES

  • Park, Joon-Sik;Oh, Won-Tae
    • Bulletin of the Korean Mathematical Society
    • /
    • v.29 no.1
    • /
    • pp.15-24
    • /
    • 1992
  • The purpose of this paper is to parameterize range-equivalence classes of all eigenmaps of flat 3-tori $T^{3}$= $R^{3}$.LAMBDA., .LAMBDA.= $c_{1}$ $e_{1}$ + $c_{2}$ $e_{2}$ + $c_{3}$ $e_{3}$, into the standard unit spheres. In this paper, we classify $A_{ 0 \lambda}$( $T^{3}$)(cf..cint.1) which is contained in $A_{\lambda}$( $T^{3}$), are belonging to $A_{ 0 \lambda}$( $T^{3}$). Moreover, as an application, we show that the only minimally imbedded flat torus into ( $S^{5}$ , can) which is contained in $A_{ 0 \lambda}$( $T^{3}$) is the generalized Clifford torus.rd torus.

  • PDF

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

RRP Loading Patterns and Standard Dimensions for Block Pattern in Membership Wholesale Clubs (Membership Wholesale Club에서의 RRP 적재패턴 및 블록패턴 표준규격에 관한 연구)

  • Jung, Sung-Tae;Han, Kyu-Chul
    • Journal of Distribution Science
    • /
    • v.13 no.7
    • /
    • pp.41-51
    • /
    • 2015
  • Purpose - This study analyzes loading efficiency by loading pattern for package standardization and reduction of logistics costs, along with the creation of revenue for the revenue review panel (RRP) of Membership Wholesale Clubs (MWC). The study aims to identify standard dimensions that can help improve the compatibility of the pallets related to display patterns preferred by the MWC and thereby explore ways to enhance logistics efficiency between manufacturers and retailers through standardization. Research design, data, and methodology - The study investigates and analyzes the current status based on actual case examples, i.e., manufacturer A and Korea's MWC (A company, B company, and C company), and thus devises improvement measures. To achieve this, the case of manufacturer A delivering to MWC was examined, and the actual pallet display patterns for each MWC were investigated by visiting each distribution site. In this study, TOPS (Total Optimization Packaging Software, USA) was used as the tool for pallet loading efficiency simulations the maximum allowable dimension was set to 0.0mm to prevent the pallet from falling outside the parameters, and the loading efficiency was analyzed with the pallet area. In other words, the study focused on dimensions (length x width x height) according to the research purpose and thereby deduced results. Results - The analysis of pallet loading patterns showed that the most preferred loading patterns for loading efficiency according to product specification, such as pinwheel, brick, and block patterns, were used in the case of the general distribution products, but the products were configured with block patterns in most cases when delivered to MWCs. The loading efficiency by loading pattern was analyzed with respect to 104 nationally listed standard dimensions. Meanwhile, No.51 (330 × 220mm) of KS T 1002 (1,100 × 1,100mm) was found to be the dimension that could bring about an improved loading efficiency, over 90.0% simultaneously in both the T-11 and T-12 pallet systems in a loading pattern configuration with the block pattern only, and the loading efficiency simulation results also confirmed this as the standard dimension that can be commonly applied to both the T-11 pallet (90.0%) and the T-12 pallet (90.7%) systems. Conclusions - The loading efficiency simulation results by loading pattern were analyzed: For the T-11 pallet system, 17 standard dimension sizes displayed the loading efficiency of 90.0% or more as block patterns, and the loading capacity was an average of 99.0%. For the T-12 pallet system, 35 standard dimension sizes displayed the loading efficiency of more than 90% as block patterns (the average loading efficiency of 98.6%). Accordingly, this study proposes that the standard dimensions of 17 sizes with the average loading efficiency of 99.0% should be applied in the use of the T-11 pallet system, and those of 35 sizes with the average loading efficiency of 98.6% should be reviewed and applied in the use of the T-12 pallet system.

Confidence Interval for Capability Process Indices by the Resampling Method (재표집방법에 의한 공정관리지수의 신뢰구간)

  • 남경현
    • Journal of Applied Reliability
    • /
    • v.1 no.1
    • /
    • pp.55-63
    • /
    • 2001
  • In this paper, we utilize the asymptotic variance of $C_{pk}$ to propose a two-sided confidence interval based on percentile-t bootstrap method. This confidence interval is compared with the ones based on the standard and percentile bootstrap methods. Simulation results show that percentile-t bootstrap method is preferred to other methods for constructing the confidence interval.l.

  • PDF

Standardization of diagnosis of cold hypersensitivity of hands and feet by D.I.T.I.

  • Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2004
  • Cold hypersensitivity means a condition feeling cold at a temperature when one should not feel so. Cold hypersensitivity has been diagnosed based on the patient's subjective complaints. But these days, cold hypersensitivity can be diagnosed by the help of D.I.T.I.(Digital Infrared Thermal Imaging) This study is designed to verify the validity of diagnosis of cold hypersensitivity by D.I.T.I. Thermographic findings of 100 outpatients who visited the Kangnam Korean Hospital, KyungHee University, Seoul, Korea, from June 2000 to November 2000 were analyzed. The experimental group consisted of 50 patients who complained cold hypersensitivity, and for the control group, 50 patients who did not complain cold hypersensitivity. For the diagnosis of cold hypersensitivity of the hands, thermographic measurements were performed on two pairs of areas(palm-upper arm and back of hand-upper arm). And for that of the feet, other two pairs of areas(anterior thigh-top of the feet and posterior thigh-heel). When the criterion for thermal deviation between the palm and the upper arm was appointed as higher than $0.3^{\circ}C$, the sensitivity was 94.0% and the specificity, 90.0%. And when the criterion for that between the anterior thigh and the top of feet was appointed higher than $2.0^{\circ}C$, the sensitivity was 94.0% and the specificity, 76.0%. Through this study, the diagnostic standard for cold hypersensitivity of hands and feet could be presented.

  • PDF

For the chlorophyll decrease and formation of Chlorolla variegata by Glucose-Culture (II) Influence of temperature and pH (Chlorella Variegata Beijerinck 의 Glucose 배양에 있어서의 Chlorophyll 증감관계에 관한연구 (제 2 ) .pH 의 영향에 대한)

  • 이현순
    • Korean Journal of Microbiology
    • /
    • v.5 no.1
    • /
    • pp.20-23
    • /
    • 1967
  • I studied about temperature and pH concentration having influence upon chlorophyll decrease on the Glucose culture of Chlorella variegata Beijerinck(211/10a). I cultured under $25^{\circ}C$(standard), $15^{\circ}C$ and $35^{\circ}C$ and compared with each other. The culture of $15^{\circ}C$ didn't have any large difference with the standard culture($25^{\circ}C$) but the culture of $35^{\circ}C$ had a large amount of chlorophyll decrease without carbohydrate accumulation, stimulation of cell division and nitrogen-deficiency. Chlorella variegata had optimum pH 6.5-7 and was a little weak in all phenomenon under pH 8 rather than under pH 6.5-7. Under pH 5 they had deep chlorophyll decrease without phephytin.

  • PDF

Vibration Serviceability Evaluation of Prestressed Concrete Girder Bridge (공용중인 PSC 거더 교량의 진동사용성 평가)

  • Park, Sun-Joon;Kang, Sung-Hoo;Kim, Bo-Hwoan;Kim, Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.781-786
    • /
    • 2009
  • The thesis shows that we gauged vibration of vehicular load regarding WPC girder bridge and researched into dynamic characteristics(natural frequency, vibration acceleration) of WPC girder bridge. By the basic of that, we researched on vibration serviceability by looking over and being compared to vibration criteria we had before. In the thesis, the gauged vibration made an analysis of vertical acceleration through FFT method and evaluated vibration serviceability about vibration sense the body feels by means of the standard of ISO assessment standard and Meister assessment standard by referring to analysis data. This research on bridge is WPC girder bridge of 90m span, width of 5.5m, and the experiment was gauged by a fluent which is right way and inverse way about dump truck of gross 270kN. Acceleration was located in the middle of 1st span, 2nd span, 3rd span. As a result of appraisal standard of Meister, the vibrations of the bridge have distributed between "Level C, Strongly Perceptible" and "Level B, Disturbing". Also the vibration can be attacked with unpleasant feeling. As a result of appraisal standard of ISO, from vibration influence didn't come to 60s, and reduced comfort boundary in part of most rigorous standard that such a case didn't happen.

  • PDF

Vibration Serviceability Evaluation of Prestressed Concrete Girder Bridge (공용중인 PSC 거더 교량의 진동사용성 평가)

  • Kang, Sung-Hoo;Kim, Bo-Hwoan;Park, Sun-Joon;Kim, Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.4
    • /
    • pp.331-337
    • /
    • 2010
  • The thesis shows that we gauged vibration of vehicular load regarding WPC girder bridge and researched into dynamic characteristics(natural frequency, vibration acceleration) of WPC girder bridge. By the basic of that, we researched on vibration serviceability by looking over and being compared to vibration criteria we had before. In the thesis, the gauged vibration made an analysis of vertical acceleration through FFT method and evaluated vibration serviceability about vibration sense the body feels by means of the standard of ISO assessment standard and Meister assessment standard by referring to analysis data. This research on bridge is WPC girder bridge of 90 m span, width of 5.5 m, and the experiment was gauged by a fluent which is right way and inverse way about dump truck of gross 270 kN. Acceleration was located in the middle of 1st span, 2nd span, 3rd span. As a result of appraisal standard of Meister, the vibrations of the bridge have distributed between "level C, strongly perceptible" and "level B, disturbing". Also the vibration can be attacked with unpleasant feeling. As a result of appraisal standard of ISO, from vibration influence didn't come to 60s, and reduced comfort boundary in part of most rigorous standard that such a case didn't happen.