• 제목/요약/키워드: Standard Apartment House

검색결과 105건 처리시간 0.021초

대학생의 미래주거 선호에 대한 연구 (A Study on University Student's Preference for own House in Future)

  • 곽경숙;김지현
    • 한국가정과학회지
    • /
    • 제9권3호
    • /
    • pp.37-45
    • /
    • 2006
  • The purpose of this study was university student's preference for own house in future according to gender. This was the investigation of which 512 university students in Jeollabukdo province. In this statistical analysis, SPSS 11.5 program was utilized to calculate percentage, mean and standard deviation. Also, these materials were verified by factor analysis, t-test and $x^2$-test. The results of this study were as follows: The university students' future housing environment preferences has been appeared to be higher in the environmental equipment and the natural scenery. In the case of the gender variables was appeared to be higher for female than male students. The future housing area most of the university students wanted the medium city or over, $25{\sim}33\;p'y{\breve{o}}ng$ apartment, 3 bed rooms, 2 bathroom. In case most students have a yard in their future house, they'd like to grow lawn and trees. Also, they wanted to live in a short distance with their future parents-in-law. Therefore, It was desirable that make a plan based on the results of this study future-residing for the new generation.

  • PDF

패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구 (A Study of Critical Items and Related Standards on Designing for Passive Apartments)

  • 이명주
    • 대한건축학회논문집:계획계
    • /
    • 제34권7호
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

공동주택의 표준자재 범용화를 위한 정보요소의 연계 및 개발방안 연구 (Study on the Linking Method of Information Factors in order to use in wide of Standard Material into Apartment Housing Construction)

  • 박근수;임석호
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.448-451
    • /
    • 2008
  • This study is under doing to suggest application manual using assembling reference plane design & standard finish material basis upon material classification code as a tool of a linkage between building design and construction standarization in order to enlarge the applicability of house building material that is produced by the module plant. We can say the goal of building standardization intend not only the improvement of construction productibility but also guarantee of subsequent performance through automatization basis upon informationalization of building design. For a etabilishing of this condition, it is neccessary to link the standardization's result of material--design--construction field. According to this neccessity, we are going to suggest information factor that can make relative business manager easily approach to the standardization practical task.

  • PDF

A LINKING METHOD OF INFORMATION FACTORS FOR ADOPTING STANDARD MATERIALS INTO APARTMENT HOUSING CONSTRUCTION

  • Geun-Soo Park;Seok-Ho Lim
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1148-1154
    • /
    • 2009
  • This study focus on the suggestion of application manual using assembling reference plane design & standard finish material basis upon material classification code. We see it will function as a tool of a linkage between building design and construction standarization in order to enlarge the applicability of house building material that is produced by the module plan. For a estabilishing of this condition, it is neccessary to link the standardization's result of material--design--construction field. According to this neccessity, we are going to suggest information factor that can make relative business manager easily approach to the standardization practical task.

  • PDF

공동주택에서 주방후드 소음과 풍량 측정 (Measurement noise and air flow of kitchen hood in the apartment)

  • 박철용;홍구표;김상훈;장동운
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.476-479
    • /
    • 2007
  • Kitchen hood was used exhausting contaminants and heat during cook. But many people do not use it easily because of the noise. Therefore this study was measured the noise when kitchen hood was working according to air flow mode. Because there are no measuring and analyzing standards in the setting house, it was referred to KS C 9304(Korean Standard). The result was shown the higher sound level than 45dB. Also it was compared the air flow that measured in the house and specified the brochure during the operation of the hood.

  • PDF

도시주택 수납공간 계획에 관한 연구 -침실별 의.침 구류 수납공간 체적산정을 중심으로- (A Study on the Plan of Storge Space in Urban Housing -base on the volume calculation of storage space for clothes and bed-clothes in each rooms-)

  • 손광제
    • 대한가정학회지
    • /
    • 제27권4호
    • /
    • pp.73-84
    • /
    • 1989
  • The purpose of this study is to induce user to use storage equipment as fixed storage space in urban housing. The object of investigation is limited to the resident of detached and apartment house in Daegu, analysised the problems and their attitueds of using storage equipments amount of cloths and bel-clothes. On the basis of these recommended the optimum volume of storage space for clothes and bed-clothes by family types. Applied to the standard of detached house, the optimum volume of storage space for clothes and bed-clothes in each rooms are as following. 1) The volume of master room is ranged 7.34M3 and 8.65M3 the average is 7.97M3. 2) Children's room is ranged 1.18M3 and 3.26M3, the average is 2.51M3 under number of users and their age. 3) The aged room is calculated average 6.53M3.

  • PDF

실측자료 기반의 공동주택 시간별 전력소비 패턴 분석 연구 (An Analysis of Electricity Consumption Profile based on Measurement Data in High-rise Apartment Complex)

  • 임경업;윤종호;신우철;박재상;김강식
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.127-132
    • /
    • 2011
  • Worldwide, the building energy simulation becomes inevitable step for predicting the energy consumption in building. In simulation process, the expertise is required for the accurate analysis results. In Korea, however, most of user use the inconsistent data with Korea circumstance. In this step, we need to construct the standard input data matched building in Korea. In this study, electricity consumption of apartments in Daejeon is analyzed. The yearly data of a apartment complexes of 2009 are analyzed as monthly, daily(week and weekend), timely, and completion year. With this result, we are able to predict the demand pattern of electricity in a house and make the schedule by demand pattern. The results of this study are followed. The averaged amount of electricity consumption in winter is higher than summer because of the high capacity of heating equipment. All of the house has electric base load from 0.26kWh to 0.5kWh. The average of the electricity consumption of month is shown as 326.7kWh. A week is seperated as 4 part such as week, weekend, Saturday and Sunday. During week, the average of timely electricity consumption is shown as 0.442kWh. The Saturday consumption is 0.453kWh. The Sunday is 0.461kWh.

  • PDF

공동주택에서 마스터룸(Master room) 평면 유형별 수요자 의식 조사 연구 (A Study on Demanders' Consciousness by Master Room Planning Types in Apartment House)

  • 조성우;이수용;문출성;오세규
    • 한국주거학회논문집
    • /
    • 제19권6호
    • /
    • pp.9-20
    • /
    • 2008
  • The residential environment is a place which reflects the gradual evolution of human consciousness because it is a cultural space the term, 'houses' is not relevant in this context as it literally means 'contains'. The long history of human living habits cannot be 'contained' within a space, but can be 'expressed' by a space and by the way the space is used. Furthermore, due to the way it is typically constructed, the basic characteristics of the house usually cannot be rapidly changed to accommodate new habits. However, recent changes that have taken place to the characteristics of the traditional master room suggest that traditional societal values associated with patriarchy have diminished. The current trend where priority is given to children's education also affects such a change. Existing researches related to the master room is confined to the behavioral use of the space and the composition of the physical space, while research on the master room its plane type has not been carried out. Therefore, in this study, apartment model houses are selected, and are classified according to the types of master room. An analysis is then carried out of the master room based on the occupants' requirements in terms of consciousness. Any planning modifications where required are then suggested. This research comprises the followings stages. First, an examination is carried out of existing research on the master room in order to understand its background and spatial components. A definitiones of related terms is also provided. Second, an analysis is carried out of the model houses exhibited at Suwan District, examining the typical standard that has been selected for the master room. Third, an analysis is conducted of the topics and questions to be selected for a questionnaire. Fourth, an analysis is carried out of the consciousness, satisfaction and requirements of the residents, as respondents in the questionnaire, related to the master room. and Research is then conducted of the architectural methods for planning the master room. Finally, future countermeasures for planning the master room are described based on the above analysis and research findings.

공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구 (An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom)

  • 이태강;고광필;김항;송국곤;김선우
    • 한국소음진동공학회논문집
    • /
    • 제18권6호
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

공동주택 강제 환기 시스템의 건물에너지 측면에서의 장기적 운영 방안에 관한 연구 (A Study on the Long-term Operating plan of Ventilation System of Apartment House in terms of Energy Performance)

  • 김승철;윤종호;백남춘;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.115-123
    • /
    • 2011
  • Because buildings recently built have been highly insulated and highly airtight, it is impossible to emit toxic substances from interior finishing materials only by natural ventilation. Therefore, they cause indoor air pollution and it may threaten the user"s health such as atopic dermatitis, bronchial asthma and (allergic) rhinitis. Domestically, users spend indoors 80 percent of their time of a day. With the increased interest in indoor air quality, the introduction of forced ventilation system for new-built apartment buildings has been legislated. However, toxic substances from indoor are mostly below there commended standard approximately 23 months later. Thus, this study has assumed the status of the apartment buildings 23 months later through a simulation, regarded $CO_2$ as an exclusive indoor air pollution source. In the process of effectively eliminating the $CO_2$, this study has also been conducted on an operating plan that can provide superior performance from the energy side.

  • PDF