• Title/Summary/Keyword: Standard $deviation(\sigma)$

Search Result 91, Processing Time 0.026 seconds

A study on the process optimization of microcellular foaming injection molded air-conditioner drain pen (화학적 초미세 발포 사출성형을 이용한 에어컨 드레인 펜의 공정 최적화에 대한 연구)

  • Kim, Joo-Kwon;Kwak, Jae-Seob;Kim, Jun-Min;Lee, Jun-Han;Kim, Jong-Sun
    • Design & Manufacturing
    • /
    • v.11 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • In this study, we applied microcellular foaming injection molding process to improve the performance of system air-conditioner drain fan which had been produced by injection molding process and studied the optimization of process conditions through 6-sigma process and response surface method (RSM) to reduce weight and deformation of products. Additive type, melt temperature, mold temperature, and injection screw shape were selected as the factor affecting the weight and deformation of the products by carrying out analysis of trivial many through ANOVA and design of experiment (DOE) method. Among the effect factor, we set the addictive type to Long G/F and screw shape to foaming screw which had the highest level of weight reduction and deformation reduction. The amount of foaming agent gas was set at 60 ml, which was the limit beyond which the weight of product did not decrease any more. For melt temperature and mold temperature, we studied the conditions where both weight and deformation were minimized using the RSM. As a result, we set the melt temperature to $250^{\circ}C$, fixed mold temperature to $20^{\circ}C$, and moving mold temperature to $40^{\circ}C$. The improvement effect was analyzed by appling the selected optimal conditions to the production process using the microcellular foaming injection molding. The results showed that the mean weight of product was measured to be 1,420g which was 19% lower than that measured in the current process. The standard deviations of the weights were found to be similar to those in the current process and it showed a low dispersion. The mean deformation was measured to be 0.9237mm, which represented a 57% reduction compared to the mean deformation in the current process, and the standard deviation decreased from 0.3298mm to 0.1398mm. Moreover, we analyzed the process capability for deformation, and the results showed that the short-term process capability increased from 2.73 to 6.60 which was even higher than targeted level of 6.0.

Analysis of Response Spectrum of Ground Motions from Recent Earthquakes (최근 발생지진 관측자료를 이용한 응답스펙트럼 분석)

  • Kim, Jun-Kyoung
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.490-497
    • /
    • 2009
  • The horizontal and vertical response spectra using the observed ground motion from the recent 5 macro earthquakes were analysed and then were compared to both the seismic design response spectra(Reg Guide 1.60), applied to the domestic nuclear power plants, and the Korean Standard Design Response Spectrum for general structures and buildings(1997). 74 horizontal and 89 vertical observed ground motions, without considering soil types, were used for normalization with respect to the peak acceleration value of each ground motion. The results showed that the horizontal MPOSD(Mean Plus One Sigma Standard Deviation) response spectra revealed much higher values for the whole frequency bands above 1 Hz than Reg. Guide(1.60). For the vertical response spectra, the results showed slightly higher than just between 7 and 8 Hz frequency band. The results were also compared to the Korean Standard Response Spectrum for the 3 different soil types and showed that the horizontal MPOSD response spectra revealed much higher values for the whole periods below 2 second(0.5 Hz) than those of SE soil type. The vertical response spectra showed similar to the values of the Korean Standard Response Spectrum of SD soil type. These spectral values dependent on frequency could be related to characteristics of the domestic crustal attenuation and the effect of each site amplification. However, through the qualitative improvements and quantitative enhancement of the observed ground motions, the conservation of horizontal seismic design response spectrum should be considered more significantly for the whole frequency bands above the 1 Hz.

Determination of 3-D Positions on TBMs Using the Precise GPS Data analysis SW, GAMIT/GLOBK (정밀 GPS 해석 S/W GMAIT/GLOBK를 활용한 TBM의 3차원 위치 결정)

  • Yoo, Kyung-Wan;Yang, In-Tae;Lee, Dong-Ha
    • Journal of Industrial Technology
    • /
    • v.36
    • /
    • pp.71-76
    • /
    • 2016
  • In this study, we determined the precise coordinates of TBMs (Tidal Bench Marks), which used as the national reference points in coastal area of Korea, using a GPS data analysis SW for the academic and scientific applications, GAMIT/GLOBK. For accurate 3-D positioning of TBM locations, we performed the GPS point surveying according to the national surveying policy and also acquired the GPS data for 48 TBMs located in the western and southern coastal part of Korea. Considering the results of baseline analysis to each observation session obtained from GAMIT module, the baseline analysis was realized to be done precisely because the values of Normalized RMS (NRMS) were mostly less than ${\pm}0.20mm$. Before the network adjustment using GLOBK module, we evaluated the suitability of observations for each session by applying the chi-squared test (${\chi}^2$ test) to the degree of freedom in observed session. An overall distributions of ${\chi}^2$ test were less than 1.0 for all sessions, and the statistical of ${\chi}^2$ test showed the average, 0.267 with minimum and maximum value, 0.063 and 0.653, respectively. Finally, we analyzed the network adjustment for 48 TBMs to reduce the residuals of baseline analysis on each point by connecting with 42 permanent GPS stations in Korea. In the network adjustment procedure, we set up the weighted values of each permanent station to be allocated between 0.9 and 1.14, and also removed the observed points having residual exceeds 4-times of standard deviation ($4{\sigma}$).

  • PDF

A Comparison of Calibration Methods for the COCOMO II Post-Architecture Model (COCOMOII의 후구조 모델에 대한 캘리브레이션 방법 비교)

  • Yoon, Myoung-Young
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.05a
    • /
    • pp.135-143
    • /
    • 2000
  • The COCOMO Ⅱ model is well-suited for the new software development life cycle such as non-sequential and rapid-development processes. The traditional regression approach based on the least square criterion is the most commonly used technique for empirical calibration in the COCOMO Ⅱ model. But it has a few assumptions frequently violated by software engineering data sets. It is true that the source data is also generally imprecise in reporting size, effort, and cost-driver ratings, particularly across different organizations. And that the outlier for the source data is a peculiarity and indicates a data pint To cope with difficulties, in this paper, we propose a new regression method for calibrating COCOMO Ⅱ post-architecture model based on the minimum relative erro(MRE) criterion. The characteristic of the proposed method is insensitive to the extreme values of the data in the empirical calibration. As the experimental results, It is evident that our proposed calibration method MRE was shown to be superior to the traditional regression approach for model calibration, as illustrated by the values obtained for standard deviation(^σ), and prediction at level L PRED(L) measures.

  • PDF

Analysis of Response Spectrum of Ground Motions from Odaesan Earthquake (2007/01/20) (오대산지진(2007/01/20) 관측자료를 이용한 응답스펙트럼 분석)

  • Kim, Jun-Kyoung
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.871-877
    • /
    • 2007
  • The response spectrum was studied using the observed pound motion from the Odaesan Earthquake (2007/01/20), and then the results were compared to the seismic design response spectra (Reg Guide 1.60) applied to the domestic nuclear power plants. For the response spectrum analysis, 21 horizontal and 8 vertical observed Pound motions were used for normalization and statistical analysis. The results showed that the MPOSD (Mean Plus One Sigma Standard Deviation) response spectra above 10 Hz revealed higher values than the design response spectra and those below 10 Hz revealed much lower values fur both horizontal and vertical response spectra. These results suggest that the response spectra (Reg. Guide 1.60), used as seismic design code for nuclear facilities in Korea, especially above about 10 Hz, should be reexamined fur apllication to the nuclear power plants structures operated in the Korean Peninsula.

Point-diffraction interferometer for 3-D profile measurement of light scattering rough surfaces (광산란 거친표면의 고정밀 삼차원 형상 측정을 위한 점회절 간섭계)

  • 김병창;이호재;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.5
    • /
    • pp.504-508
    • /
    • 2003
  • We present a new point-diffraction interferometer, which has been devised for the three-dimensional profile measurement of light scattering rough surfaces. The interferometer system has multiple sources of two-point-diffraction and a CCD camera composed of an array of two-dimensional photodetectors. Each diffraction source is an independent two-point-diffraction interferometer made of a pair of single-mode optical fibers, which are housed in a ceramic ferrule to emit two spherical wave fronts by means of diffraction at their free ends. The two spherical wave fronts then interfere with each other and subsequently generate a unique fringe pattern on the test surface. A He-Ne source provides coherent light to the two fibers through a 2${\times}$l optical coupler, and one of the fibers is elongated by use of a piezoelectric tube to produce phase shifting. The xyz coordinates of the target surface are determined by fitting the measured phase data into a global model of multilateration. Measurement has been performed for the warpage inspection of chip scale packages (CSPs) that are tape-mounted on ball grid arrays (BGAs) and backside profile of a silicon wafer in the middle of integrated-circuit fabrication process. When a diagonal profile is measured across the wafer, the maximum discrepancy turns out to be 5.6 ${\mu}{\textrm}{m}$ with a standard deviation of 1.5 ${\mu}{\textrm}{m}$.

A Metal Enhanced Flow-Injection Chemiluminescence Method for the Rapid Determination of Norfloxacin in Pharmaceutical Formulations and Serum Sample

  • Kamruzzaman, Mohammad;Ferdous, Taslima;Alam, Al-Mahmnur;Lee, Sang-Hak;Kim, So-Yeun;Kim, Young-Ho;Kim, Sung-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.639-644
    • /
    • 2011
  • A simple and highly sensitive chemiluminescence method to determine norfloxacin (NFLX) has been proposed by measuring the chemiluminescence (CL) intensities using a flow injection (FI) system. The CL intensity of the luminol-$H_2O_2$ system is strongly enhanced by the addition of Cu (II) in alkaline condition. The CL intensity is substantially increased after the injection of NFLX into the luminol-$H_2O_2$-Cu (II) system. The enhancement effect is attributed to a catalytic effect of Cu (II) due to the interaction with NFLX which forms a complex with the catalyst. Under the optimal conditions, the sensitizing effect of the CL intensity is proportional to the concentration of NFLX in the range of $1.5{\times}10^{-9}-5.9{\times}10^{-7}molL^{-1}$ (r = 0.9994) with a detection limit ($3{\sigma}$) of $2.98{\times}10^{-10}molL^{-1}$. The proposed method had good reproducibility with the relative standard deviation (RSD, n = 5) of 1.6% for $1{\times}10^{-7}molL^{-1}$ of NFLX. The possible reaction mechanism of the CL reaction is also discussed. This method has been successfully applied for the determination of trace amount of NFLX in pharmaceutical preparations and serum samples.

Estimation of Monkman-Grant Parameter for Type 316LN and Cr-Mo Stainless Steels (316LN 및 Cr-Mo 스테인리스강의 Monkman-Grant 파라메타 평가)

  • Kim, Woo-Gon;Kim, Sung-Ho;Lee, Kyung-Yong;Ryu, Woo-Seog
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.223-230
    • /
    • 2001
  • The Monkman-Grant (M-G) and its modified parameters were estimated for modified type 316LN and $9{\sim}12Cr-1Mo$ steels with chemical variations. Several sets of creep data were obtained by constant-load creep tests in $550-650^{\circ}C$ ranges. The relation parameters, m, $m^*$, C and $C^*$ were proposed and discussed for two alloy systems. In creep fracture mode, type 316LN steel showed domination of the intergranular fracture caused by growth and coalescence of cavities. On the other hand, the Cr-Mo steel showed transgranular fracture of the ductile type caused from softening at high temperature. In spite of the basic differences in creep fracture modes as well as creep properties, the M-G and its modified relations demonstrated linearity within the $2{\sigma}$ standard deviation. The value of the m parameter of the M-G relation was 0.90 in the 316LN steel and 0.84 in the Cr-Mo steel. The value of the $m^*$ parameter of the modified relation was 0.94 in the 316LN steel and 0.89 in Cr-Mo steel. The modified relation was superior to the M-G relation because the $m^*$ slopes almost overlapped regardless of creep testing conditions and chemical variations to the two alloy systems.

  • PDF

Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

  • Mani, Karthick Raj;Upadhayay, Sagar;Das, K.J. Maria
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.90-100
    • /
    • 2017
  • Purpose: To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. Materials and Methods: We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous integrated boost technique. IMRT and VMAT plans were performed with jaw tracking (JT) and with static jaw (SJ) technique by keeping the same constraints and priorities for a particular patient. Target conformity, dose to the critical structures and low dose volumes were recorded and analyzed for IMRT and VMAT plans with and without JT for all the patients. Results: The conformity index average of all patients followed by standard deviation (${\bar{x}}{\pm}{\sigma}_{\bar{x}}$) of the JT-IMRT, SJ-IMRT, JT-VMAT, and SJ-VMAT were $1.72{\pm}0.56$, $1.67{\pm}0.57$, $1.83{\pm}0.65$, and $1.85{\pm}0.64$, and homogeneity index were $0.059{\pm}0.05$, $0.064{\pm}0.05$, $0.064{\pm}0.04$, and $0.064{\pm}0.05$. JT-IMRT shows significant mean reduction in right parotid and left parotid shows of 7.64% (p < 0.001) and 7.45% (p < 0.001) compare to SJ-IMRT. JT-IMRT plans also shows considerable dose reduction to thyroid, inferior constrictors, spinal cord and brainstem compared to the SJ-IMRT plans. Conclusion: Significant dose reductions were observed for critical structure in the JT-IMRT compared to SJ-IMRT technique. In JT-VMAT plans dose reduction to the critical structure were not significant compared to the SJ-IMRT due to relatively lesser monitor units.

Highly Sensitive Luminescence Assessment of Bile Acid Using a Balofloxacin-Europium(III) Probe in Micellar Medium

  • Cai, Huan;Zhao, Fang;Si, Hailin;Zhang, Shuaishuai;Wang, Chunchun;Qi, Peirong
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.4145-4149
    • /
    • 2012
  • A novel and simple method of luminescence enhancement effect for the determination of trace amounts of bile acid was proposed. The procedure was based on the luminescence intensity of the balofloxacin-europium(III) complex that could be strongly enhanced by bile acid in the presence of sodium dodecyl benzene sulfonate (SDBS). Under the optimum conditions, the enhanced luminescence intensity of the system exhibited a good linear relationship with the bile acid concentration in the range $5.0{\times}10^{-9}-7.0{\times}10^{-7}\;mol\;L^{-1}$ with a detection limit of $1.3{\times}10^{-9}\;mol\;L^{-1}$ ($3{\sigma}$). The relative standard deviation (RSD) was 1.7% (n = 11) for $5.0{\times}10^{-8}\;mol\;L^{-1}$ bile acid. The applicability of the method to the determination of bile acid was demonstrated by investigating the effect of potential interferences and by analyzing human serum and urine samples. The possible enhancement mechanism of luminescence intensity in balofloxacin-europium(III)-bile acid-SDBS system was also discussed briefly.