References
- Lee N, Puri DR, Blanco AI, Chao KS. Intensity-modulated radiation therapy in head and neck cancers: an update. Head Neck 2007;29:387-400. https://doi.org/10.1002/hed.20332
- Ng J, Shuryak I. Minimizing second cancer risk following radiotherapy: current perspectives. Cancer Manag Res 2014;7:1-11.
- LoSasso T, Chui CS, Ling CC. Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. Med Phys 1998;25:1919-27. https://doi.org/10.1118/1.598381
- Cadman P, McNutt T, Bzdusek K. Validation of physics improvements for IMRT with a commercial treatmentplanning system. J Appl Clin Med Phys 2005;6:74-86. https://doi.org/10.1120/jacmp.v6i2.2083
- Feng Z, Wu H, Zhang Y, Zhang Y, Cheng J, Su X. Dosimetric comparison between jaw tracking and static jaw techniques in intensity-modulated radiotherapy. Radiat Oncol 2015;10:28. https://doi.org/10.1186/s13014-015-0329-4
- International Commission on Radiation Units and Measurements. Prescribing, recording, and reporting photonbeam intensity-modulated radiation therapy (IMRT): contents (ICRU Report 83). J ICRU 2010;10:NP.
- Snyder KC, Wen N, Huang Y, et al. Use of jaw tracking in intensity modulated and volumetric modulated arc radiation therapy for spine stereotactic radiosurgery. Pract Radiat Oncol 2015;5:e155-62. https://doi.org/10.1016/j.prro.2014.09.002
- Joy S, Starkschall G, Kry S, et al. Dosimetric effects of jaw tracking in step-and-shoot intensity-modulated radiation therapy. J Appl Clin Med Phys 2012;13:136-45. https://doi.org/10.1120/jacmp.v13i2.3707
- Kim JI, Park JM, Park SY, Choi CH, Wu HG, Ye SJ. Assessment of potential jaw-tracking advantage using control point sequences of VMAT planning. J Appl Clin Med Phys 2014;15:160-8.
- Schmidhalter D, Fix MK, Niederer P, Mini R, Manser P. Leaf transmission reduction using moving jaws for dynamic MLC IMRT. Med Phys 2007;34:3674-87. https://doi.org/10.1118/1.2768864
- Lee CC, Wu A, Garg M, et al. A new approach to reduce number of split fields in large field IMRT. Med Dosim 2011;36:1-5. https://doi.org/10.1016/j.meddos.2009.10.001
- Chao KS, Deasy JO, Markman J, et al. A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: initial results. Int J Radiat Oncol Biol Phys 2001;49:907-16. https://doi.org/10.1016/S0360-3016(00)01441-3
- Trotti A. Toxicity in head and neck cancer: a review of trends and issues. Int J Radiat Oncol Biol Phys 2000;47:1-12. https://doi.org/10.1016/S0360-3016(99)00558-1
Cited by
- Assessment of the modulation degrees of intensity-modulated radiation therapy plans vol.13, pp.1, 2018, https://doi.org/10.1186/s13014-018-1193-9
- Dosimetric Comparison Between Jaw Tracking and No Jaw Tracking in Intensity-Modulated Radiation Therapy vol.18, pp.None, 2019, https://doi.org/10.1177/1533033819841061
- A 3D-printed patient-specific applicator guide for use in high-dose-rate interstitial brachytherapy for tongue cancer: a phantom study vol.64, pp.13, 2017, https://doi.org/10.1088/1361-6560/ab277e
- Development of an Assemblable, Daily, Quality-Assurance Device for Line-Scanning Proton Therapy vol.75, pp.4, 2017, https://doi.org/10.3938/jkps.75.344
- Dosimetric comparison of jaw tracking in intensity modulated and volumetric modulated arc radiotherapy for carcinoma of cervix vol.25, pp.3, 2017, https://doi.org/10.2478/pjmpe-2019-0021
- Comparison of O-ring and General Linacs for Treatment Planning of Volumetric Modulated Arc Therapy vol.76, pp.4, 2017, https://doi.org/10.6009/jjrt.2020_jsrt_76.4.339
- The use of collimator angle optimization and jaw tracking for VMAT‐based single‐isocenter multiple‐target stereotactic radiosurgery for up to six targets in the Varian Eclipse tre vol.22, pp.9, 2017, https://doi.org/10.1002/acm2.13360
- Comparison of combinations of irradiation techniques and jaw conditions in intensity‐modulated radiotherapy for lung cancer vol.22, pp.10, 2017, https://doi.org/10.1002/acm2.13416