• Title/Summary/Keyword: Stand-alone System

Search Result 455, Processing Time 0.022 seconds

Development of Stand-alone Performance Test System for an Intake-diffuser of the Waterjet Propulsion (Waterjet 추진장치의 흡입구유도관 단독성능 시험기법 개발)

  • Ahn Jong-Woo;Kim Ki-Sup;Park Young-Ha;Kim Kyung-Youl
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.6
    • /
    • pp.15-23
    • /
    • 2004
  • In order to investigate efficiency and flowfield charateristics of the intake-diffuser for the ship waterjet propulsion, new experimental verification technology was set up in the cavitation tunnel. 1-hole and 5-hole pilot tubes were designed and manufactured to measure the pressure and velocity distributions at intake-diffuser entrance and impeller inlet. The calibration of the 5-hole pilot tubes is conducted at the cavitation tunnel The cavitation inception occurs at the intake lip, and the occurrence position depends on IVR (Inlet Velocity Ratio) condition. The present experimental device will be applied sufficiently for the development of the design and performance improvement technologies.

Improvement Alternative of Korean Environmental Assessment through the EA of the European Union (유럽연합의 EA에 비춰본 한국의 환경평가제도 개선 방안)

  • Kim, Im-Soon;Han, Sang-Wook;Park, Joo-Hyun
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.139-155
    • /
    • 2006
  • The introduction of Strategic Environmental Assessment (SEA) has strengthened and extended the value of Environmental Impact Assessment (EIA) as a fundamental tool for sustainable development. In particular, SEA helps to overcome the limitation of project EIA as a stand alone approach that is applied relatively late in the decision making cycle. SEA is applied to proposals of policy, plan, and/or programme when major alternatives are open. In Korea, similar to SEA, the Prior Environmental Review System (PERS) was introduced to overcome the limitations of the EIA, by checking the environmental impacts on major policy and administrative actions in the early stage of decision making process. SEA appears in various national, regional and international laws. SEA is addressed specifically in the UNECE SEA protocol to the Espoo Convention on Environmental Impact Assessment in a transboundary context, as well as the European Commission SEA Directive (2001/42/EC). SEA is a valuable tool for integrating sustainability decisions into country's policies, plans and programmes. This paper reviews the policy direction for implementation of the SEA and efficient Environmental Assessment (EA) through integration of the PERS and the EIA.

Survey of Electro-Optical Infrared Sensor for UAV

  • Jang, Seung-Won;Kim, Joong-Wook
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.1
    • /
    • pp.124-134
    • /
    • 2008
  • The rising demand for the high efficiency and high covertness in UAV motivates the miniature design of the high performing mission sensors, or payloads. One of the promising payload sensors, EO/IR sensor has evolved satisfying its demands and became the main stand-alone mission sensor for 200kg-range UAV. One aspect in development of EO/IR sensor concerns lack of specification criterions to represent its performance. Even though the high demand and competition among each manufacturer caused EO/IR features subject to rapid change collateral to new technology, the datasheets maintained the conventional outdated formats which leave some of the major components in ambiguity. Making comparisons or predicting actual performance with such datasheets is hardly worthwhile; yet, they could be important reference guide for the potential customers what to expect for the upcoming EO/IR. According to UAS Roadmap 2007-2032 published by DoD, one of the main potential customers as well as a main investor of EO/IR technology, EO/IR is expected to play key roll in solving urgent problems, such as see and avoid system. This paper will examine the recent representative EO/IR specialized in UAS missions through datasheets to find out current trend and eventually extrapolate the possible future trend.

  • PDF

Optimized LCL filter Design Method of Utility Interactive Inverter (계통연계형 인버터의 LCL필터 최적 설계기법)

  • Jung, Sang-Hyuk;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

A Study of the Integrated Operation for Databases with Different Data Structures (상이한 데이터 구조의 데이터베이스간 통합 운영방안 연구 - 기초학문자료센터를 중심으로 -)

  • Ko, Young-Man;Bae, Kyung-Jae
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.45 no.3
    • /
    • pp.69-85
    • /
    • 2011
  • This study reviewed theories for database integration, which combines heterogeneous data structures, and suggested a practical method to integrate databases of Korean Research Memory(KRM) and Infrastructural Basic Research(IBR) as a case study. In order to broadly distribute the outcomes of IBR, it is essential to be connected to and integrated with the database of KRM. As a solution, it was suggested that the current database of IBR should follow standard guidelines as a XML database, and its future database should be integrated with the database of KRM or be established as a stand-alone system

Performance Analysis of a Smart Antenna Test-bed Operating in a IS2000 Environment (IS2000 환경에서 스마트 안테나 Test-bed의 성능분석)

  • 임흥재;최승원
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1061-1070
    • /
    • 2002
  • In this paper, we present a performance analysis of the smart antenna test-bed operating in a IS2000 1x through a test-bed that has been implemented on a DSP(TMS320C6711) board. The test-bed consists of a PC (for generating the RX data), beam-former(i.e., a stand-alone PCB for weight computation), and an interfacing module. The performance improvements compared to a normal base station system consisting of a single antenna are shown in terms the BER(bit error rate) in the wide-band CDMA channel.

A Study and Implementation of Network Synchronization Module for Wired and Wireless based Multimedia Embedded Systems (유무선 기반 멀티미디어 임베디드 시스템을 위한 네트워크 동기화 모듈 연구 및 구현)

  • Kim, Hong-Kyu;Moon, Seung-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.12
    • /
    • pp.1198-1206
    • /
    • 2007
  • It is common to use PC or Digital picture frame in stand-alone fashion to view images, movies, or to listen MP3 musics which are considered as multimedia contents, However, such existing methods have weakness for expanding network requirements or augmenting extra data, in such case inevitably requiring external devices. With keeping in mind for such expansion, in this study, we have suggested a new concepts of network module which may utilize an image server for data transmission, in the proposed module, data alarm packet was defined for alerting incoming data from the image server and it became possible to synchronize between the image server and device not only in wired but also in wireless environments through UART. The method consists of a control module for an image server and a synchronization module between the server and the device. We have also tested the feasibility for future commercial usages such as advertisements through performance evaluations.

Control of MPPT and DC-DC converter for a stand alone solar power system using a single digital controller (단일 디지털 제어기를 이용한 독립형 태양광 발전 시스템의 MPPT 및 DC-DC컨버터 제어)

  • Jin, Ho-Sang;Kim, Hee-Jun;Ahmad, Jawad
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.115-117
    • /
    • 2009
  • 본 논문은 단일 디지털 제어기를 이용하여 독립형 태양광 발진 시스템에 사용되는 태양전지에서 발생한 전력을 수집하고 필요에 따라 에너지 저장 장치에 전력을 저장하는 Boost 컨버터가 최대전력점에서 동작하도록 제어하면서, 이 전압을 부하에 필요한 전압 값으로 변환하는 Buck 컨버터를 동시에 제어하는 방법을 제안한다. 제안된 독립형 태양광 발전 시스템의 구성은 에너지를 발생하는 태양전지, 최대전력 점을 추종(MPPT)하도록 하는 Boost 컨버터, 부하에 적합한 준위의 전압을 공급하는 Buck 컨버터가 직렬로 연결되어 있다. 제안된 방법은 디지털 제어기의 제어변수 값들을 바꿈으로써 전체시스템의 출력특성을 쉽게 제어할 수 있어, 사용되는 태양전지 어레이의 종류와 환경조건 변화에 따라 쉽게 제어변수 값들을 조정할 수 있다. 또한 하나의 디지털 제어기로 최대전력점 제어부 및 Buck과 Boost 컨버터의 피드백 제어부를 구성하여 시스템의 구조가 간단해지기 때문에 소형 및 경량화를 이룰 수 있다.

  • PDF

Design and Verification of Improved Cascaded Multilevel Inverter Topology with Asymmetric DC Sources

  • Tarmizi, Tarmizi;Taib, Soib;Desa, M.K. Mat
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1074-1086
    • /
    • 2019
  • This paper presents the design and implementation of an improved cascaded multilevel inverter topology with asymmetric DC sources. This experimental inverter topology is a stand-alone system with simulations and experiments performed using resistance loads. The topology uses four asymmetric binary DC sources that are independent from each other and one H-bridge. The topology was simulated using PSIM software before an actual prototype circuit was tested. The proposed topology was shown to be very efficient. It was able to generate a smooth output waveform up to 31 levels with only eight switches. The obtained simulation and experimental results are almost identical. In a 1,200W ($48.3{\Omega}$) resistive load application, the THDv and efficiency of the topology were found to be 1.7% and 97%, respectively. In inductive load applications, the THDv values were 1.1% and 1.3% for an inductive load ($R=54{\Omega}$ dan L=146mH) and a 36W fluorescent lamp load with a capacitor connected at the dc bus.

The influence of the water ingression and melt eruption model on the MELCOR code prediction of molten corium-concrete interaction in the APR-1400 reactor cavity

  • Amidu, Muritala A.;Addad, Yacine
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1508-1515
    • /
    • 2022
  • In the present study, the cavity module of the MELCOR code is used for the simulation of molten corium concrete interaction (MCCI) during the late phase of postulated large break loss of coolant (LB-LOCA) accident in the APR1400 reactor design. Using the molten corium composition data from previous MELCOR Simulation of APR1400 under LB-LOCA accident, the ex-vessel phases of the accident sequences with long-term MCCI are recalculated with stand-alone cavity package of the MELCOR code to investigate the impact of water ingression and melt eruption models which were hitherto absent in MELCOR code. Significant changes in the MCCI behaviors in terms of the heat transfer rates, amount of gases released, and maximum cavity ablation depths are observed and reported in this study. Most especially, the incorporation of these models in the new release of MELCOR code has led to the reduction of the maximum ablation depth in radial and axial directions by ~38% and ~32%, respectively. These impacts are substantial enough to change the conclusions earlier reached by researchers who had used the older versions of the MELCOR code for their studies. and it could also impact the estimated cost of the severe accident mitigation system in the APR1400 reactor.