• 제목/요약/키워드: Stand-Alone Mode

검색결과 75건 처리시간 0.026초

전기자동차용 리튬이온 배터리 급속충전장치 설계와 제어 (A Design and Control of Rapid Electric Vehicle Charging System for Lithium-Ion Battery)

  • 강태원;서용석;박현철;강병익;김성훈
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.26-36
    • /
    • 2013
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charge mode, constant-current mode, and constant-voltage mode. The pre-charge mode employs the stair-case shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is specified to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 78A. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

PEBB Based Bi-directional Rapid Charging System for EV Traction Battery

  • Kang, Taewon;Chae, Beomseok;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.323-324
    • /
    • 2013
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charge mode, constant-current mode, and constant-voltage mode. The pre-charge mode employs the stair-case shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is specified to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 78A. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

  • PDF

Rapid Electric Vehicle Charging System with Enhanced V2G Performance

  • Kang, Taewon;Kim, Changwoo;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungik;Kim, Simon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.201-202
    • /
    • 2012
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charging mode, constant-current mode, and constant-voltage mode. Each mode is operated according to battery states: voltage, current and State of Charging (SOC). The proposed system is able to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 67A. The optimal discharging algorithm for Vehicle to the Grid (V2G) operation has been adopted to maintain the discharging current of 1C. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system. Experiment waveforms confirm the proposed functionality of the charging system.

  • PDF

마이크로그리드에서의 데드 밴드와 회복 제어를 적용한 배터리 에너지저장시스템 주파수 제어 (Frequency Control of Battery Energy Storage System with a Deadband and Restoration Control in Microgrid)

  • 이학주;최진영;최종찬;원동준;채우규;박중성
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1584-1589
    • /
    • 2012
  • The grid-interconnected microgrid can be able to operate with and without the utility microgrid to supply electricity. when the microgrid operates in grid-connected mode, the frequency of the microgrid synchronizes with the system frequency. In this case, the frequency of the microgrid has small variation which is able to change the output of distributed generation with a droop controller. Thus, the small variation of frequency can make the distributed generation generate unnecessary electricity consistently. In this paper, we propose a frequency droop control with a dead band so as to prevent the distributed generations from generating unnecessary output while in grid-interconnected mode. In addition, a distributed generation can have a restoration control to restore the frequency changed by a droop control as a rated frequency. Also, we state the problem of restoration control with a dead band, and propose its solution when the microgrid operates in stand alone mode. We simulate the proposed droop control using PSCAD/EMTDC to verify the validity of the control.

Sliding Mode Control of a New Wind-Based Isolated Three-Phase Induction Generator System with Constant Frequency and Adjustable Output Voltage

  • Moradian, Mohammadreza;Soltani, Jafar
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.675-684
    • /
    • 2016
  • This paper presents a new stand-alone wind-based induction generator system with constant frequency and adjustable output voltage. The proposed generator consists of a six-phase cage-rotor induction machine with two separate three-phase balanced stator windings and a three-phase space vector pulse width modulation inverter that operates as a static synchronous compensator (STATCOM). The first stator winding is fed by the STATCOM and used to excite the machine while the second stator winding is connected to the generator external load. The main frequency of the STATCOM is determined to be constant and equal to the load-requested frequency. The generator output frequency is independent of the load power demand and its prime mover speed because the frequency of the induced emf in the second stator winding is the same as this constant frequency. A sliding mode control (SMC) is developed to regulate the generator output voltage. A second SMC is used to force the zero active power exchanged between the machine and the STATCOM. Some simulation and experimental results are presented to prove the validity and effectiveness of the proposed generator system.

계통연계형 인버터의 LCL필터 최적 설계기법 (Optimized LCL filter Design Method of Utility Interactive Inverter)

  • 정상혁;최세완
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

위치기반 푸쉬서비스 플랫폼 설계 및 구현 (Design and Implementation of a Location-Based Push-Service Platform)

  • 심재민;이응재;주용완;남광우;류근호
    • 한국공간정보시스템학회 논문지
    • /
    • 제11권4호
    • /
    • pp.47-55
    • /
    • 2009
  • 최근 이동전화, 와이브로, HSDPA 등 무선인터넷 기술이 발전하면서 이용자의 위치, 상황을 고려한 교통, 관광, 쇼핑 및 긴급구조 등의 맞춤형서비스들이 주목받고 있다. 이용자의 상황에 맞는 맞춤형서비스 제공을 위해서는 무선 단말기를 장착하고 이동하는 이동객체의 연속적으로 변화하는 위치 정보, 시간 정보, 그리고 속도 변화와 같은 동적인 특성 등을 종합적으로 고려해야 한다. 이 논문은 이동객체가 발생시키는 컨텍스트 처리를 위한 트리거의 유형을 정의하고 이러한 트리거를 처리하기 위한 방법들을 설계하고 이용자의 위치에 따라 정보를 제공하기 위한 이동객체의 컨텍스트 트리거를 포함하는 위치기반 푸쉬서비스 플랫폼을 제안한다. 제안된 시스템은 휴대폰 및 텔레매틱스 단말 내장형 GPS의 Ms-assisted 측위 모드 또는 Stand-alone 측위 모드를 기반으로 단말에서 이동객체 스트립 정보를 수집하고, 이용자 단말 에이전트를 통해 이용자의 컨텍스트를 추출하여 이를 서버에 전송하도록 분산 처리 기능을 갖는다.

  • PDF

하이브리드 전기추진시스템 구축을 위한 SEIG의 출력 특성 분석 (Behavior Analysis of a Self Excited Induction Generator with Various Loads for a Hybrid Electric Propulsion System)

  • 양주호;최교호;이재민;정석권
    • 동력기계공학회지
    • /
    • 제22권1호
    • /
    • pp.41-47
    • /
    • 2018
  • This paper analyzes the output characteristics of a self excited induction generator with isolated mode according to change of its speeds and loads for building a hybrid electric propulsion system in special purpose ships by using power take off. The induction generators are being considered as an alternative choice to the well-developed generators because of their lower unit cost, inherent ruggedness, operational and maintenance simplicity. However, the generator working by stand alone has a few problems that the reactive power is required to establish the air gap magnetic flux, and the induced voltage and magnetizing current fluctuate when the load is varied. In spite of its advantages, basic design data of the capacitor bank and behaviors of the output characteristics of the generator are not sufficient for the system. Based on the operating condition(speed range of main engine) of the target boat, a reduced experimental equipment system was constructed to analyze the output characteristics of the SEIG. And a suitable capacitor bank of a stand-alone generator and its output characteristics under various loads was investigated in detail through these experiments. According to the experimental result, it was confirmed that the capacitor bank should be $70{\mu}F{\sim}100{\mu}F$, and the proper SEIG induced voltage should be DC 80 V ~ 250 V in order to storage electrical energy into a battery.

전류원 인버터의 병렬운전에 의한 축전지 없는 태양광 시스템의 구성 (Stand-Alone PV System by Parallel Operation Control of Current-Source Inverter without Battery)

  • 박성준;김종달
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권6호
    • /
    • pp.291-297
    • /
    • 2003
  • This paper presents a current-source-inverter based on a buck-boost configuration and its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150 [W] prototype equipped with digital signal processor TMS320F241.

의료 정보(심전도 데이터) 전송을 위한 무선 LAN MAC 계층 구현에 관한 연구 (A Study on the Implementation of Wireless LAN MAC(medium access control) Layer for a Medical Information Transmission)

  • 류점수;고성일;김영길
    • 전자공학회논문지S
    • /
    • 제34S권12호
    • /
    • pp.50-59
    • /
    • 1997
  • A wireless LAN medical information transmission system is useful for patients who need mobility in a local area environment. This paper proposes a method using WLAN(wireless local area network) and implements a stand-alone system with MAC(meidum access control) layer protocol referenced IEEE 802.11 draft standard. The system consists of a 8bit-microprocessor which handles media access control protocol and a WL100(GEC Plessey) chip which takes care of phsical layer specific routines and uses a RF module DE6003(GEC Plessey). The major features of the implemented system are the CSMA/CA protocol used a consecutive DATA-ACK trasmission method which yields more effective bandwidth allocation for asyncronous traffic transmission and the modified PCF protocol for time-bounded traffic transmission, which operates in ad-hoc network topology apart from IEEE 802.11 draft standard confirm PCF mode operate in infrastruture topology.

  • PDF