• 제목/요약/키워드: Stainless steel (SS)

검색결과 159건 처리시간 0.026초

Effects of Surface Machining by a Lathe on Microstructure of Near Surface Layer and Corrosion Behavior of SA182 Grade 304 Stainless Steel in Simulated Primary Water

  • Zhang, Zhiming;Wang, Jianqiu;Han, En-hou;Ke, Wei
    • Corrosion Science and Technology
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 2019
  • To find proper lathe machining parameters for SA182 Grade 304 stainless steel (SS), six kinds of samples with different machining surface states were prepared using a lathe. Surface morphologies and microstructures of near surface deformed layers on different samples were analysed. Surface morphologies and chemical composition of oxide films formed on different samples in simulated primary water with $100{\mu}g/L\;O_2$ at $310^{\circ}C$ were characterized. Results showed that surface roughness was mainly affected by lathe feed. Surface machining caused grain refinement at the top layer. A severely deformed layer with different thicknesses formed on all samples. In addition to high defect density caused by surface deformation, phase transformation, residual stress, and strain also affected the oxidation behaviour of SA182 Grade 304 SS in the test solution. Machining parameters used for # 4 (feed, 0.15 mm/r; back engagement, 2 mm; cutting speed, 114.86 m/min) and # 6 (feed,0.20 mm/r; back engagement, 1 mm; cutting speed, 73.01 m/min) samples were found to be proper for lathe machining of SA182 Grade 304 SS.

Electrochemical Advanced Oxidation of Lamotrigine at Ti/DSA (Ta2O5-Ir2O5) and Stainless Steel Anodes

  • Meena, Vinod Kumar;Ghatak, Himadri Roy
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.292-307
    • /
    • 2022
  • The study presents kinetics of degradation and mineralization of an anti-epileptic drug Lamotrigine (LAM) in the aqueous matrix by electrochemical advanced oxidation process (EAOP) on Ti/DSA (Ta2O5-Ir2O5) and Stainless Steel (SS) anodes using sodium sulphate as supporting electrolyte. On both the anodes, kinetic behaviour was pseudo-first-order for degradation as well as mineralization of LAM. On Ti/DSA anode, maximum LAM degradation of 75.42% was observed at an associated specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 100 ppm Na2SO4 concentration. Maximum mineralization attained was 44.83% at an associated specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 50 ppm concentration of Na2SO4 with energy consumption of 2942.71 kWh/kgTOC. Under identical conditions on SS anode, a maximum of 98.92% LAM degradation was marked after a specific charge (Q) of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 100 ppm concentration of Na2SO4. Maximum LAM mineralization on SS anode was 98.53%, marked at a specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 75 ppm concentration of Na2SO4, with energy consumption of 1312.17 kWh/kgTOC. Higher Mineralization Current Efficiency (MCE) values were attained for EAOP on SS anode for both degradation and mineralization due to occurrence of combined electro-oxidation and electro-coagulation process in comparison to EAOP on Ti/DSA anode due to occurrence of lone electro-oxidation process.

기성금관 수복어린이에서의 니켈내성균에 관한 연구 (A STUDY OF NI-RESISTANT BACTERIA ON THE RESTORED STAINLESS STEEL CROWN)

  • 정샛별;이긍호
    • 대한소아치과학회지
    • /
    • 제27권2호
    • /
    • pp.274-282
    • /
    • 2000
  • 소아의 유구치 수복에 흔히 사용하는 stainless steel crown은 주성분으로 $70\sim90%$의 니켈과 $5\sim15%$의 크롬을 함유하고 있다. 이 중 니켈 자체가 일으킬 수 있는 allergy반응이나 발암성등의 부작용이 성인에서는 활발하게 연구되고 있으며, 특히 니켈이 포함된 합금을 이용한 보철물 주변에 병원성이 있는 니켈내성 Enterococci가 존재한다는 보고가 있어 성인과는 구강환경이 다른 소아에서도 stainless steel crown 주변에 니켈내성균주가 존재하는지를 확인하고자 이 실험을 시행하였다. 유구치에 stainless steel crown(Anatom primary crown, Sankin)을 6개월 이상 장착한 환자 15명과 유구치 협면에 치아우식증이 없는 환자 15명의 치은열구액에서 채취한 시료를 BHI 한천배지, 니켈배지 및 Bile-esculin azide(BEA) 한천 배지에 도말하였다. BEA한천배지에서 자란 enterococci를 니켈내성정도를 확인하기위해 3, 5, 10, 30, 50mM 니켈배지에 접종한후 성장상태를 관찰하였다. 실험군에서는 BHI 한천배지에서 507,350개의 균주가 분리되었으며, 이 중 니켈내성세균(3mM)은 53,864 균주였다. 대조군에서는 BHI 한천배지에서 414,590 균주가, 니켈내성세균(3mM)은 37,523 균주가 분리되었다. BEA한천배지에서는 실험군의 경우 95개가 분리되었으며, 대조군에서는 20개의 균주만이 분리되었다. BHI 한천배지에서 분리된 총 균주 수를 100으로 놓았을 때 3mM 니켈배지에서 분리된 균주는 실험군에서는 10.62%, 대조군에서는 9.05%를 차지하여 두 군간에 뚜렷한 차이는 없었으며, 3mM 니켈배지에서 자란 총 균주 수와 BEA 한천배지에서 배양된 enterococci를 3mM 니켈배지로 옮겨 배양했을 때와 비교하면, 실험군에서 0.13%, 대조군에서 0.03%로 모두 1%이하의 분포를 차지하였다.

  • PDF

식중독 미생물의 biofilm 형성에 대한 계피, 정향 및 레몬그래스 정유의 억제 효과 (Inhibitory Effects of Cinnamon, Clove and Lemongrass Essential Oils against Biofilm Formation by Food Poisoning Bacteria)

  • 김형은;김용석
    • 한국식품위생안전성학회지
    • /
    • 제36권5호
    • /
    • pp.430-439
    • /
    • 2021
  • 항균활성이 뛰어난 식물 정유를 이용하여 식품가공 기구 및 용기에 다양하게 사용되는 polyethylene과 stainless steel 표면에 형성된 식중독 6종의 biofilm 형성에 대한 억제 효과를 연구하였다. 식물 정유 20종의 식중독 미생물에 대한 항균활성을 disk diffusion 방법으로 평가한 결과 cinnamon > clove > lemongrass > peppermint > pine needle 순으로 항균활성을 나타냈다. Cinnamon과 clove 정유의 최소억제농도(MIC)와 최소살균농도(MBC)는 각각 0.63-1.25 mg/mL과 1.25-2. mg/mL의 범위를 나타냈으며, lemongrass 정유의 MIC와 MBC는 각각 1.25-2.50 mg/mL과 2.50-5.00 mg/mL로 약간 낮은 항균활성을 나타냈다. 정유 3종의 biofilm 형성 예방효과는 식중독 미생물과 polyethylene 및 stainless steel에 따라 다소 차이가 있었지만, 0.5% 농도의 cinnamon, clove와 lemongrass 정유를 식품접촉 표면에 미리 코팅하였을 때 biofilm 형성에 영향을 주는 것을 확인하였다. 정유의 농도가 증가할수록 모든 식중독 미생물에 대해서 biofilm 형성을 유의적으로 억제하였으며(P<0.05), 0.5% cinnamon과 clove 정유 처리에 의해 L. monocytogenes ATCC 19112와 S. aureus KCCM 11812의 biofilm이 형성되지 않았다. Polyethylene과 stainless steel coupon 표면에 형성된 식중독 미생물의 biofilm의 제거 효과를 측정한 결과, 식중독 미생물의 종류에 따라 차이가 있었지만 정유의 농도가 증가할수록 biofilm 제거 효과는 높아졌으며, 대체로 clove 정유의 biofilm 제거율이 높은 것으로 나타났다. 본 연구를 통하여 0.5%의 cinnamon과 clove 정유는 polyethylene과 stainless steel 표면에 식중독 미생물이 형성하는 biofilm을 예방, 성장 억제 및 제거할 수 있는 천연 소재로 적용이 가능한 것으로 나타났다.

Stainless steel hand file과 Ni-Ti rotary file을 이용한 근관 형성시 근단부 근관 형태의 순차적 변화에 대한 평가 (Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography)

  • 이우진;이정호;전경아;서민석;유연지;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.231-237
    • /
    • 2011
  • 연구목적: 본 연구에서는 micro CT를 사용하여 SS K-file, Profile, LightSpeed로 #25부터 #40 크기까지 근관을 형성할 때 근단부 근관 형태의 연속되는 변화를 평가하였다. 연구 재료 및 방법: 30개 하악 대구치의 근심 근관을 ProFile, LightSpeed와 SS K-file로 #25번에서 #40번까지 순차적으로 근관 형성하였고, 매 단계 확대 후 micro CT를 시행하였다. 치근단 1, 2, 3, 5 mm 에서 근관 중심 변위와 삭제되지 않은 단면의 비율을 측정하여 'repeated nested design' 분석방법과 Mann-Whitney test로 유의 수준 p = 0.05에서 검정하였다. 결과: SS K-file군에서 #30 이상 근관 형성 후 유의할 만한 근관 중심 변위가 증가하였고, 근관 형성 과정 어느 단계에서도 삭제되지 않은 면적의 비율이 유의성 있게 감소되지 않았다. ProFile군에서는 치근단 1, 2 mm에서 #40 file로 근관 형성 후 근관 중심 변위가 크게 증가하였고, 치근단 1 mm에서 #35 크기로 근관 형성한 후에 삭제되지 않은 면적의 비율이 유의성 있게 감소하였다. LightSpeed군에서는 급격한 근관 중심 변위를 관찰할 수 없었고, 근관 중심 변위가 ProFile군보다 적게 관찰되었다. 결론: SS K-file, Profile, LightSpeed에서 형성되는 근관의 변이 정도는 근단부 근관 형성 크기에 따라 다르게 나타났다.

Type 316L 스테인리스강의 고온 기계적 거동 (High-Temperature Mechanical Behaviors of Type 316L Stainless Steel)

  • 김우곤;이형연
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.92-99
    • /
    • 2020
  • High-temperature mechanical behaviors of Type 316L stainless steel (SS), which is considered as one of the major structural materials of Generation-IV nuclear reactors, were investigated through the tension and creep tests at elevated temperatures. The tension tests were performed under the strain rate of 6.67×10-4 (1/s) from room temperature to 650℃, and the creep tests were conducted under different applied stresses at 550℃, 600℃, 650℃, and 700℃. The tensile behavior was investigated, and the modeling equations for tensile strengths and elongation were proposed as a function of temperature. The creep behavior was analyzed in terms of various creep equations: Norton's power law, modified Monkman-Grant relation, damage tolerance factor(λ), and Z-parameter, and the creep constants were proposed. In addition, the tested tensile and creep strengths were compared with those of RCC-MRx. Results showed that creep exponent value decreased from n=13.55 to n=7.58 with increasing temperature, λ = 6.3, and Z-parameter obeyed well a power-law form of Z=5.79E52(σ/E)9.12. RCC-MRx showed lower creep strength and marginally different in creep strain rate, compared to the tested results. Same creep deformation was operative for dislocation movement regardless of the temperatures.

금침과 스테인레스침을 이용한 온침에서의 부위별 온도측정 연구 (The Study on Temperature Measurement of Warm Needling Using Stainless Steel Needle and Gold Needle)

  • 여수정
    • Korean Journal of Acupuncture
    • /
    • 제30권3호
    • /
    • pp.178-184
    • /
    • 2013
  • Objectives : The warm needling technique is the method combining the effects of acupuncture needle with those of moxibustion. We need to standardize the characteristics of the warm needling technique, in order to get more systematic and objective results in operation and effects and then get more clinical abilities in these fields. Methods : In this study, using labview system on the warm needling technique, we measured and compared partial temperature changes according to the kind of needle. We studied relations of moxa cones of various sizes with the peak combustion temperature. Results and Conclusions: When we measured the warm needling's partial temperature, temperature measured at 1 and 2 cm below the head, according to the kind of needle, gold needle got the higher result on the peak than SS304 stainless steel needle. In the case of combustion of the moxa cones, cones weighing 0.4 g and 0.8 g, respectively, and the apex ignition method with gold needle showed the higher result than the apex ignition method with stainless steel needle, when we measured the effective stimulus time at 2 cm below the head and the mean temperature during the effective stimulus time. Although more research to standardize the characteristics of the warm needling technique will be needed, we suggest, according to these results, that warm needling of gold needle combined with moxa cone of 0.4 or 0.8 g is effective.

초내식성 스테인레스강의 금속이온용출특성 및 세포적합성 (Metal Ion Release Behaviour and Cytotoxicity of a Super Stainless Steel)

  • 김철생;박진수;허억;강곤
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.11-18
    • /
    • 1996
  • The toxic metal ion release behaviour and the cytotoxicity of a super stainless steel (S.S.S, 22cr-20Ni -6Mo-0.25N) were investigated The measurement of the amount of static and wear- induced trace metal ion released from the steels was conducted in Hank's balanced salt solution using an electrothermal atomic absdrption spectrometry equiped with Uaphite furnace. And the in vitro cytotoxicity of the materials was assesed in cell culture. The static dissolution rates of Fe and Cr ions from the S.S.S were significantly lower than those of 316L SS. However, the Ni ion release from the S.S.S during the first 4 weeks was yester than that from 316L 55 by 15-45%. Also, the wear-in- duces dissolution rates from the steels were not correlated either with their elemental composition rates or with the static metal ion release rates. The S.S.S did not deteriorate the osteoblasts viability. And no toxic response was observed from the macrophages cultured for 7 days in RFMI 1640 medium immersed with the S.S.S specimens.

  • PDF

알루미늄 기지 자동차에 쓰이는 탄소강 리벳과 그라파이트간의 갈바닉 부식 방지 연구 (Study on Prevention of Galvanic Corrosion between Carbon Steel Rivets and Graphite Used in Aluminum Matrix Automobiles)

  • 서동일;이재봉
    • Corrosion Science and Technology
    • /
    • 제16권3호
    • /
    • pp.128-140
    • /
    • 2017
  • Aluminum alloy matrix may be used for manufacturing lighter automobiles. However, galvanic corrosion may occur between the rivet joint combining aluminum alloy matrix and a CFRP (carbon fiber reinforced plastic) laminate. The possibility of galvanic corrosion may be investigated by measuring galvanic couple currents. Two types of galvanic current measuring methods were used. One method is to use potentiodynamic polarization curves and the other is the ZRA (zero resistance ammeter) method. For galvanic corrosion experiments graphite, a major component of CFRP, was used with carbon steel (rivets) and 6061 aluminum alloys. Regardless of carbon steel, Ni deposited carbon steel, and 316L stainless steels we also investigated the possibility of reduction in galvanic corrosion. Results revealed that even though Ni deposited carbon steel or 316L stainless rivet may slightly increase galvanic current density between those and Al matrix, substitute rivets for carbon steel may be considerably useful for reducing overall galvanic corrosion.

ITER 일차벽의 Cu/SS Mock-up에 대한 고열부하 시험 (High Heat Flux Test of Cu/SS Mock-up for ITER First Wall)

  • 이동원;배영덕;홍봉근;이종혁;박정용;정용환
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.325-330
    • /
    • 2006
  • ITER (International Thermonuclear Experimental Reactor) 조달용 일차벽의 제조 건전성을 검증하기 위해서, 일차벽을 구성하는 Cu/SS mock-up을 제작하여 고열부하 시험을 수행하였다. Cu/SS mock-up은 CuCrZr과 SS316L이 사용되었으며, 두 금속은 $1050^{\circ}C$, 150 MPa의 조건에서 고온등방가압법 (HIP, Hot Isostatic Pressing) 과정을 통해 접합되었다. 시험에 사용된 고열부하 장치는 일본 원자력연구소의 JEBIS (JAEA Electron Beam Irradiation Stand)를 이용하였으며, 시험 조건은 FEM 코드인 ANSYS 해석을 통해 결정하였다. 시험은 $5MW/m^2$의 고열부하를 15초간 인가하고, 30초간 냉각하는 방법으로 수행되었으며, 시험 종료 후 얻어진 시험결과와 해석결과가 잘 일치함을 확인하였다.