• Title/Summary/Keyword: Stack Protection

Search Result 54, Processing Time 0.027 seconds

A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated high frequency signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lim, Byung-Ho;Kim, Chul-Hwan;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1376-1378
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range In this respect, this paper describes the basis of a Protection technique for transmission lines which utilises high-frequency components. Fault-generated signals caused by post-fault and the signal derived from stack tuner is connected to the coupling capacitor of CVT. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the Protected zone, and to discriminate the fault type on transmission line.

  • PDF

An Analysis of Carbon-14 Metabolism for Internal Dosimetry at CANDU Nuclear Power Plants (중수로 원전 종사자의 방사선량 평가를 위한 $^{14}C$ 인체대사모델 분석)

  • Kim, Hee-Geun;Lee, Hyung-Seok;Ha, Gak-Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.207-213
    • /
    • 2003
  • Carbon-14 is one of the major radionuclides released by CANDU Nuclear Power Plants(NPPs). It is almost always emitted as gas through the stack. From CANDU NPPs about 95% of all carbon-14 is released as carbon dioxide. Carbon-14 is a low energy beta emitter which, therefore, gives only a small skin dose from external radiation. As carbon dioxide Is physiologically rather inert gases for man's metabolism, the inhalation dose is probably less than 1 % of the ingestion dose. But this source of carbon-14, formed in a closed, nor-oxidative environment, was subsequently released into the workplace as an insoluble particulate when these systems were opened lip for re-tubing at CANDU NPPs. As a part of the improvement of dosimetry program at Wolsong Nuclear Power Plants, the carbon-14 metabolism based on references was investigated and studied to setup the internal dosimetry program due to inhalation of carbon-14.

A Study on the Change of Condensable Particulate Matter by the SO2 Concentration among Combustion Gases (연소 배출가스 중 SO2 농도에 따른 응축성먼지 변화에 관한 연구)

  • Yu, JeongHun;Lim, SeulGi;Song, Jihan;Lee, DoYoung;Yu, MyeongSang;Kim, JongHo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • Particulate matter (PM) emitted from fossil fuel-combustion facilities can be classified as either filterable or condensable PM. The U.S. Environmental Protection Agency (EPA) defined condensable PM as material that is in the phase of vapor at the stack temperature of the sampling location which condenses, reacts upon cooling and dilution in the ambient air to form solid or liquid in a few second after the discharge from the stack. Condensable PM passed through the filter media and it is typically ignored. But condensable PM was defined as a component of primary PM. This study investigates the change of condensable PM according to the variation in the sulfur dioxide of combustion gas. Domestic oil boilers were used as the source of emission ($SO_2$) and the level of $SO_2$ concentration (0, 50, 80, and 120 ppm) was adjusted by diluting general light oil and marine gas oil (MGO) that contains sulfur less than 0.5%. Condensable PM was measured as 2.72, 6.10, 8.38, and $13.34mg/m^3$ when $SO_2$ concentration in combustion gas were 0, 50, 80, and 120 ppm respectively. The condensable PM tended to increase as the concentration of $SO_2$ increased. Some of the gaseous air pollutants emitted from the stack should be considered precursors of condensable PM. The gas phase pollutants which converted into condensable PM should reduced for condensable PM control.

A Study on the Configuration of BOP and Implementation of BMS Function for VRFB (VRFB를 위한 BOP 구성 및 BMS 기능구현에 관한 연구)

  • Choi, Jung-Sik;Oh, Seung-Yeol;Chung, Dong-Hwa;Park, Byung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.74-83
    • /
    • 2014
  • This paper proposes a study on the configuration of balancing of plant(BOP) and implementation of battery management system(BMS) functions for vanadium redox flow battery(VRFB) and propose a method consists of sensor and required design specifications BOP system configuration. And it proposes an method of the functions implementation and control algorithm of the BMS for flow battery. Functions of BMS include temperature control, the charge and discharge control, flow control, level control, state of charge(SOC) estimation and a battery protection through the sensor signal of BOP. Functions of BMS is implemented by the sensor signal, so it is recognized as a very important factor measurement accuracy of the data. Therefore, measuring a mechanical signal(flow rate, temperature, level) through the BOP test model, and the measuring an electrical signal(cell voltage, stack voltage and stack current) through the VRFB charge-discharge system and analyzes the precision of data in this paper. Also it shows a good charge-discharge test results by the SOC estimation algorithm of VRFB. Proposed BOP configuration and BMS functions implementation can be used as a reference indicator for VRFB system design.

Field Experimental Study on a Soft Protecting Method for Coastal Erosion Prevention (유연재를 이용한 연안잠식방지에 대한 현장실험 연구)

  • Peng, Ta-Hsiung;Jan, Chyan-Deng
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.216-222
    • /
    • 2010
  • The structural methods used to protect coastal erosion are usually very expensive in construction as well as in spending on maintaining the structures from damage. Those structures like embankments, breakwaters, jetties etc. are commonly constructed with concretes (rigid methods) to protect coastal erosion. But those rigid methods are not effective always, because the wave energy and impact force on the structures could not be effectively reduced by those methods. For avoiding sediment erosion on coastal areas by the way of reducing wave energy, a flexible breakwater is introduced which will reduce energy and protect coastline economically and environmentally. The flexible device is a combination of flexible wire nets and stack of rings made of used vehicle tires and soft blades on surfaces. This flexible wire net is placed in between two stacks of rings. The stack of rings is mainly used to hold the flexible wire nets and the flexible wire net is mainly used to reduce wave energy and helps to deposit sediments in coastal area. For a field experiment study, the above-mentioned flexible breakwater of coastal protection has been set up at the Shuang-Chun coastal area in Tainan County since June 10, 2009. The length of the flexible device is 50.0 meters and the height is 2.0 meters. The function of the device has been examined by Typhoon Linfa during June 19~22, 2009 and by Typhoon Morakot during August 6~10, 2009. The result shows that the flexible breakwater has effectively trapped sediments and let them deposit on coastal. The depth of sediment deposition around the device was about 0.5 to 0.8 meters.

A Study on the Insulation Resistance Measurement Technique for Electrical Safety of Green Car (친환경자동차의 전기안전을 위한 절연저항 측정에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon;Moon, Hyun-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.597-601
    • /
    • 2009
  • Green car such as a hybrid electrical vehicle and fuel cell vehicle is developed as a commercial target. UN/ECE/WP29 is developing GTR of HFCV and establishing the regulation and standard of electrical safety by ELSA. The regulation and standard about Electrical safety of vehicle are prescribed in ISO, UN/ECE, FMVSS, Japanese Attachment and so on, in case of insulation resistance is referred to keep more than 100/Vdc, 500/Vac. However, accurate method to measure insulation resistance agreeable to structure of vehicle does not exist now, it is actually that correctness of measurement drops according to the feature of battery and fuel cell stack. In this paper, the method to measure insulation resistance for protection against electrical shock by direct contact or indirect contact in Green Car will be indicated by making a comparison between the insulation measurement in standard of electrical safety and the experiment results for HEV and HFCV.

A Study on the Smoke Proof Measure of High Rise Buildings. (건축화재시 피난대책에 관한 연구 -고층건물의 제연을 중심으로-)

  • 이영재;이근영
    • Fire Science and Engineering
    • /
    • v.4 no.1
    • /
    • pp.3-12
    • /
    • 1990
  • This study is to Present the air Pressurization system of staircase as a way to decrease the injury of human life which is suffocated by smoke when the fire break out in building. 1) The best among an air pressurization system of stairshaft Is multiple air Injection system established to be situated an air injection point in each layer. 2) If the air pressurization system is also applied to the elevator accessory room to use commonly, it can prevent from the smoke spreading and pollution inside building caused by stack effect of elevator shaft. 3) For the reasonable and safe escape and air pressurization system must be carried out from the project of basic shape of building under the close cooperation with architect and fire protection expert.

  • PDF

A Study on Application of Shaft-box Type Double Skin to Apartment Building (공동주택에 대한 Shaft Box형 이중외피의 적용에 관한 연구)

  • Roh, Ji Wooung
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.75-81
    • /
    • 2013
  • The balcony of our apartment building consists of unique construction similar to double skin. It is announced broadly that double skin is very effective system in improvement of natural ventilation and indoor thermal environment, and outdoor sound protection. So, for the improvement of indoor climate and energy saving, many peoples studied about environmental performance of our balcony construction. This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. Proto-type was decided by analyzing various types of exiting apartments. Shaft box type balcony was created by setting up shaft space at a part of balcony. Air flow and contribution of air temperature were simulated, performance of shaft box type balcony was compared with existing balcony. Finally, we confirmed that shaft box type balcony has many possibility for improvement of indoor environment.

Solid State Pulsed Power Modulator and Its Application (반도체 스위치기반 펄스전원 기술 개발 및 응용)

  • Ryoo, Hong-Je;Jang, Sung-Roc
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.193-194
    • /
    • 2015
  • In this paper, the solid state pulsed power modulator developed in KERI, which is based on IGBT technologies are overviewed. During last ten years, several kinds of solid state modulators were developed in KERI such as IGBT stacks with step up transformer, full IGBT stack based marx generator, modified IGBT marx generator and high repetitive solid state modulator. Basic principle of the design is described and each pros and cons are compared. KERI's solid state pulsed power modulators has lot of advantages for industrial pulsed power application focused on everlasting life cycle and high repetitive, and shows superior arching protection ability.

  • PDF

MMU-less Memory Management for Stack Protection in Thread-based Operating System (MMU가 없는 Thread기반 운영체제에서 스택 보호를 위한 메모리 관리 기법)

  • Lee, Young-Rim;Kim, Young-Pil;Yoo, Chuck
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10a
    • /
    • pp.409-413
    • /
    • 2006
  • 현재 많은 센서 네트워크 운영체제에서는 메모리 제약 때문에 스레드 스택을 공유한다. 하지만 대부분의 대상 플랫폼에서는 MMU가 없어서 하드웨어적으로 스택 보호가 이루어지기 어렵다. 이러한 문제를 해결하기 위해 본 논문에서는 운영체제 바이너리 코드 안에 존재하는 스택 연산 명령어들을 스택 보호 기능을 가진 래퍼 함수호출로 바꾸어 주었다. 이 래퍼 함수는 스택의 오버플로우/언더플로우를 관리해 주고 오리지널 코드에 있던 명령어를 실행한 후 원래 실행 흐름으로 돌아가게 한다. 본 논문에서는 이러한 동작을 수행하는 Post-Compile Processing Tool의 구조와 세부 메커니즘을 제안한다. 이 툴은 직접 바이너리를 조작하므로 개발의 유연성을 살리고, 정적인 조작만 가하기 때문에 실행시간 오버헤드가 적다. 또한 임베디드 플랫폼 환경과 같이 하드웨어 자원의 제약이 있는 구조에 적합하다.

  • PDF