• Title/Summary/Keyword: Stack Data Type

Search Result 34, Processing Time 0.027 seconds

The damping efficiency of vortex-induced vibration by tuned-mass damper of a tower-supported steel stack

  • Homma, Shin;Maeda, Junji;Hanada, Naoya
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.333-347
    • /
    • 2009
  • Many tower-supported steel stacks have been constructed in Japan, primarily for economic reasons. However the dynamic behavior of these stacks under a strong wind is not well known and the wind load design standard for this type of a stack has not yet been formulated. In light of this situation, we carried out wind response observation of an operating tower-supported steel stack with and without a tuned-mass damper. The observation revealed the performance of the tuned-mass damper installed on the stack in order to control the wind-induced vibration. Based on the observed data, we performed a wind tunnel test of a specimen of the stack. In this paper we report the results of the wind tunnel test and some comparisons with the results of observation. Our findings are as follows: 1) the tuned-mass damper installed on the specimen in the wind tunnel test worked as well as the one on the observed stack, 2) the amplitude of the vortex-induced vibration of the specimen corresponded approximately to that of the observed stack, and 3) correlation between Scruton number and reduced amplitude, y/d, (y is amplitude, d is diameter) was confirmed by both the wind tunnel test and the observed results.

Detecting SQL Injection Logs Leveraging ELK Stack (ELK Stack을 활용한 SQL Injection 로그 탐지)

  • Min, Song-ha;Yu, Hyun-jae;Lim, Moon-ju;Kim, Jong-min
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.337-340
    • /
    • 2022
  • SQL Injection attacks are one of the older attack techniques and are the dominant type of hacking attempts against web services. There have been many attempts to hack SQL injection attacks by exposing data or obtaining privileges. In this paper, we implement a log analysis system that can respond to SQL injection attacks in real time using the open source ELK Stack. did. By providing a visualization of SQL injection attack log data through the implemented system, it is expected that users will be able to easily grasp the degree of attack risk and quickly prepare for attacks.

  • PDF

Effect of Field Orientation on Magnetization Loss in a Stacked Bi-2223 Conductor (자장방향이 적층 Bi-2223도체의 자화손실에 미치는 영향)

  • 류경우;김현준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-82
    • /
    • 2003
  • The ac loss is an important issue in the design of high-Tc superconducting power devices such as transformers and cables. In these devices many Bi-2223 tapes are closely stacked together and exposed to alternating magnetic fields that can have different orientations with respect to a tape. In such arrangement the magnetization loss is influenced by the screening current induced in adjacent tapes and thus different from that in a single tape. This stacking effect was experimentally investigated by measuring the magnetization loss in a stack, which consists of a number of tapes. First the magnetization loss in the single tape was measured in order to confirm the reliability of the loss data measured in the stack. The results for the single tape coincide well will the loss characteristics described in other previous works. For the stack In parallel and longitudinal magnetic fields the measured loss is Independent of both the number of tapes and stacking type. The longitudinal magnetization loss Is well explained rather by the slab model for decoupled filaments. For the tall stack in perpendicular field the measured loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is unaffected. These loss behaviors in the tall stack are well described by the slab model for full coupling.

Design of Object-Oriented Cideo Controller based on Stack (스택기반 객체 지향형 영상 제어기 설계)

  • 박주현;김영민
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.7
    • /
    • pp.69-77
    • /
    • 1998
  • In this paper, a controller is designed for efficient controlling of video data with object-oriented feature. The need of controlling video data in an object unit is on the rise for the reason of rapidly growing demand for high-quality video services. We propose a programmable architecture with stack buffers which can minimize a scheduling overhead by having separate buffes for genral data and return addresses. The buffers are veyr useful for move and copy operations for multitasking and task switching. The controller offers extended instructions that process several data types including 32bit integrer type. Operation speed of the controller is from 77MHz to 44MHz.

  • PDF

Automated Test Data Generation for Testing Programs with Multi-level Stack-directed Pointers (다단계 스택 지향 포인터가 있는 프로그램 테스트를 위한 테스트 데이터 자동 생성)

  • Chung, In-Sang
    • The KIPS Transactions:PartD
    • /
    • v.17D no.4
    • /
    • pp.297-310
    • /
    • 2010
  • Recently, a new testing technique called concolic testing receives lots of attention. Concolic testing generates test data by combining concrete program execution and symbolic execution to achieve high test coverage. CREST is a representative open-source test tool implementing concolic testing. Currently, however, CREST only deals with integer type as input. This paper presents a new rule for automated test data generation in presence of inputs of pointer type. The rules effectively handles multi-level stack-directed pointers that are mainly used in C programs. In addition, we describe a tool named vCREST implementing the proposed rules together with the results of applying the tool to some C programs.

Pressure Loss Analysis of the 75 kW MCFC Stack with Internal Manifold Separator (75 kW 용융탄산염 연료전지 (MCFC) 스택 내 압력 손실 해석)

  • Kim, Beom-Joo;Lee, Jung-Hyun;Kim, Do-Hyeong;Kang, Seung-Won;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.5
    • /
    • pp.367-376
    • /
    • 2008
  • To obtain the data of the pressure loss and differential pressure at the inside of the stack that was composed of 126 cells with 7,500 cm2 electrode area, 75kW molten carbonate fuel cell system has been operated. Computational fluid dynamics was applied to estimate reactions and thermal fluid behavior inside of the stack that was adopted with internal manifold type separator. The pressure loss coefficient K showed 72.29 to 84.01 in anode and 6.34 to 8.75 in cathode at low part of cells at the inside of 75 kW MCFC stack respectively. Meanwhile, the pressure loss coefficient of the higher part of cells at the interior of the stack showed 15.36 and 56.44 in anode and cathode respectively. These results mean that there is no big total pressure difference between anode and cathode at the inner part of 75 kW MCFC stack. This result will be reflected in 250kW MCFC system design.

Study on the Behaivor of Bubbles in Array Type Flow Channels (균일형 유로에서 기포의 거동에 관한 연구)

  • Jung, Youngguan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.84-90
    • /
    • 2013
  • The hydrogen or oxygen gas producted by electrolysis become many bubbles in the electrolyte, but exact data on the behavior of these bubbles in the separator of an electrolysis stack didn't become known. In this study, the flow visualization experiment on the behavior of bubbles in the flow pattern of the array type separator is performed by using of a visible alkaline electrolysis stack and a stereoscopic microscope. As the results, a fine size bubbles adhered to the surface of the flow pattern grow to large sized bubbles until each bubble's buoyance is lager than the sum of external force and weight. And then the large bubbles flow into the upper area of the separator. Bubbles adhered to the surface of the vertical flow pattern grow quickly than them adhered to the surface of the horizontal flow pattern. Also, he electrolysis efficiency is declined because many multi-size bubbles occupied the wide volume in the flow pattern.

A Study on the Realization of Protocol Stack for I/O Elements Control for Multi-devices and Field Level

  • Kwak, Chang-Yong;Kim, Tae-Hwa;Kwon, Soon-Jae;Son, Jeong-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.52.1-52
    • /
    • 2001
  • System establishment using a network may be a decisive factor both for creating a flexible production system and increasing reliability and serve as a basis for setting up of a management system that will make the designing, maintenance, and repair easier. It is therefore imperative to develop a protocol which is simple to use for communications and connections among different devices. The objectives of this study is to establish communications protocol stack that will enable to conduct an effective monitoring of production facilities and to secure flexibility of reduction control system, and to improve the working ratio of the production facilities by centralization of communications system through effective collecting and storing of the diversified data of multi-type and multi-device production facilities.

  • PDF

A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated High Frequency Signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lee, Dong-Jun;Kim, Chul-Hwan;Kim, Il-Dong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.924-931
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range. High frequency signals caused by sudden changes in system voltage that occurs in the immediate post-fault period are generally outside the bandwidth of receptibility of most protection scheme. In this respect, a specially designed stack tuner is connected to the coupling capacitor of CVT, in order to capture the high frequency signals. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the protected zone, and to discriminate the fault type. In this paper, modal transform is not applied to fault generated signals, because signals which are converted by modal transform are not have an information of each phase any longer. Instead, using peak voltage value of data windows is able to discriminate fault type. The paper concludes by presenting fault detection and discrimination of various faults on transmission line which are based on extensive simulation studies carried out on a typical 154kV Korean transmission line, using the EMTP software.

  • PDF

Development of a Commercial-scale RDF Boiler with Chain type Stoker (실증규모 체인스토커식 RDF전용보일러 개발)

  • Choi, Yeon-Seok;Kim, Byung-Gil;Roh, Nam-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.813-816
    • /
    • 2009
  • A commercial-scale RDF boiler that its burning capacity is 400 kg-RDF/hr and steam production capacity is 2 ton/hr. It has a chain type stoker and waste heat recovery system. Heat exchanger is vertical water-pipe so that soot blowing and removal is convenient during operation. Dry scrubber, bag filter and activated carbon tower have been installed for the reduction of air pollutant gases and dust. Analysing data of pollutants from stack such as $SO_x$. $NO_x$ and dioxin shows so good results that the boiler system could comply the regulated emission limits.

  • PDF