• Title/Summary/Keyword: Stability calculation

Search Result 654, Processing Time 0.036 seconds

Development of New Method for the Proper Component Ratio of Combined Heat and Power in Long Term Generation Expansion Planning (전력수급기본계획에 열병합발전 설비의 적정 구성비율 결정)

  • Kim, Yong-Ha;Son, Hak-Sik;Im, Yong-Jae;Na, In-Kyu;Lee, Sung-Jun;Kim, Mi-Ye;Woo, Sung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.58-60
    • /
    • 2005
  • This paper presents a optimal power flow calculation algorithm considering voltage and transient stability. In this method, voltage stability margin and transient stability constraints is incorporated into a optimal power flow calculation formulation to guarantee adequate voltage and transient security levels in power system. The proposed method is applied to IEEE-24 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

A Study on Development of Power Transfer Capability Calculation Algorithm Considering Voltage Stability Margin (전압안정도여유를 고려한 수송능력산정 알고리즘의 개발에 관한 연구)

  • Hong, S.E.;Kim, Y.H.;Lee, Buhm;Choi, S.K.;Jung, H.S.;Moon, H.K.;Lee, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.19-21
    • /
    • 2002
  • This paper presents a power transfer capability calculation algorithm Considering Voltage Stability Margin. In this method, voltage stability margin constraints are incorporated into a power transfer capability formulation to guarantee adequate voltage security levels in interconnected Power System. The proposed method is applied to IEEE-24 Reliability Test Systems and the results shows the effectiveness of the method.

  • PDF

A Study on Development of Power Transfer Capability Calculation Algorithm Considering the Closest Saddle Node Bifurcation for Voltage Stability (최단붕괴 전압안정도여유를 고려한 수송능력산정 알고리즘의 개발에 관한 연구)

  • 김용하;정현성;나인규;조성린;이재걸
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.557-562
    • /
    • 2003
  • This paper presents a power transfer capability calculation algorithm considering the closest saddle node bifurcation for voltage stability margin. In this method, voltage stability margin constraints considering the closest saddle node bifurcation are incorporated into a power transfer capability formulation to guarantee adequate voltage security levels in an interconnected power system. The proposed method is applied to IEEE-24 reliability test system and the results show the effectiveness of the method.

A Study on Development of Power Transfer Capability Calculation Algorithm Considering A Closest Saddle Node Bifurcation For Voltage Stability (최단전압붕괴점 전압안정도여유를 고려한 수송능력산정 알고리즘의 개발에 관한 연구)

  • Kim, Y.H.;Lee, Buhm;Choi, S.K.;Jung, H.S.;Lee, S.J.;Jo, S.R.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.88-90
    • /
    • 2002
  • This paper presents a power transfer capability calculation algorithm Considering A Closest Saddle Node Bifurcation For Voltage Stability Margin. In this method, voltage stability margin constraints considering a closest saddle node bifurcation are incorporated into a power transfer capability formulation to guarantee adequate voltage security levels in an interconnected Power System. The proposed method is applied to IEEE-24 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

Analysis of Voltage Stability Using the Multiple Load Row Calculation Method with Loss Redistribution Algorithm (손실재분배 알고리즘을 이용한 조류다근계산법에 의한 전압 안정도 해석)

  • Ro, Min-Ho;Kim, Keun-Seong;Park, Sun-Jae;Chae, Myoung-Seck;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.743-745
    • /
    • 1996
  • This paper presents an approach for the analysis of static voltage stability in power system. The proposed approach is based on multiple load flow calculation method using the redistribution algorithm of transmission loss, with which more realistic load flow solution can be obtained in the near of voltage collapse point. Some simulation results of the proposed approach show that the accuracy of static voltage stability analysis can be increased.

  • PDF

Analytical Study on Fire Resistance Predictions of Prestressed Concrete Slabs (프리스트레스트 콘크리트 슬래브의 내화성능 예측에 대한 해석적 연구)

  • Min, Jeong-Ki;Park, Min Jae;Ju, Young K.
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • In fire design for floors, the three criteria of stability, integrity and insulation are required for the specified fire resistance duration. Among these, stability is not easy to confirm. For solid prestressed concrete slabs of uniform thickness, Eurocode 2 provides tabulated data and specifies an axis distance to the centroid of strands to achieve particular fire resistance ratings, but it is not clear if this data can be used for a wide range of different prestressed slab profiles. In order to verify the current code-fire ratings for precast prestressed slabs, both simple and advanced calculation methods are investigated. This paper examines the use of calculation methods, accounting for the real behaviour of unprotected simply supported prestressed concrete slabs exposed to the standard ISO 834 fire. The calculated fire resistance of each prestressed concrete slab is compared with tabulated data in Eurocode part 1.2, with detailed discussion.

Development of a Computation Code for the Verification of the Vulnerability Criteria for Surf-riding and Broaching Mode of IMO Second-Generation Intact Stability Criteria (IMO 2세대 선박 복원성 기준에 따른 서프라이딩/ 브로칭 취약성 기준 검증을 위한 계산 코드 개발)

  • Shin, Dong Min;Oh, Kyoung-gun;Moon, Byung Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.518-525
    • /
    • 2019
  • Recently, the Sub-Committee on SDC (Ship Design and Construction) of IMO have discussed actively the technical issues associated with the second-generation intact stability criteria of ships. Generally, second generation intact stability criteria refer to vulnerability five modes ship stability which occurs when the ship navigating in rough seas. As waves passes the ship, dynamic roll motion phenomenon will affect ship stability that may lead to capsizing. Multi-tiered approach for second generation of intact stability criteria of IMO instruments covers apply for all ships. Each ship is checked for vulnerability to pure loss of stability, parametric roll, and broaching/surf-riding phenomena using L1(level 1) vulnerability criteria. If a possible vulnerability is detected, then the L2(level 2) criteria is used, followed by direct stability assessment, if necessary. In this study, we propose a new method to verify the criteria of the surf-riding/broaching mode of small ships. In case, L1 vulnerability criteria is not satisfied based on the relatively simple calculation using the Froude number, we presented the calculation code for the L2 criteria considering the hydrodynamics in waves to perform the more complicated calculation. Then the vulnerability criteria were reviewed based on the data for a given ship. The value of C, which is the probability of the vulnerability criteria for surf-riding/broaching, was calculated. The criteria value C is considered in new approach method using the Froude-Krylov force and the diffraction force. The result shows lower values when considering both the Froude-rylov force and the diffraction force than with only the Froude-Krylov force was considered. This difference means that when dynamic roll motion of ship, more exact wave force needs considered for second generation intact stability criteria This result will contribute to basic ship design process according to the IMO Second-Generation Intact Stability Criteria.

Development on Evaluation Technique of Stability for Safety Elevation in Fishing(Stow-Neting)Vessel (어선(안강망) 안정성능 향상을 위한 복원성 평가기법 개발)

  • 박제웅;이희준;김주남
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.4 no.2
    • /
    • pp.53-62
    • /
    • 1998
  • International Maritime Organizatin(IMO) has been chosen some of agreements for regulating the international stability criteria of fishing vessels and recommended that each goverment adopts theirs into the domestic law. As a result, 77/93 Fishing Safety Agreement was ratified. Among the above agreement, contents of stability was not only applied to domestic law, but also strenghten considerably compared with existing stability criteria. And even if the calculation guide of stability with recommendations was regualted, Analysis of stability on domestic fishing vessels never have been used according to such a caculation method. Moreover, the caculation of stability criteria caused by strong wind, rolling effect and deck inflow was not considered in the existing basic design program. Therefore, the development of stability criteria program available for such a caculation has been of vital impotance. This research has developed a stability criteria program under 77/93 Fishing Safety Agreement. Also through development of stability criteria program, the stability performance of fishing vessel with 69ton stow-nesting was evaluated.

  • PDF

Stability Analysis of Cable Yarding with Self-Propelled Carriage (자주식 반송기를 이용한 가선집재작업의 안정성분석)

  • Oh, Jae-Heun;Park, Mun Seub;Kim, Jae Won;Cha, Du Song
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.4
    • /
    • pp.495-500
    • /
    • 2006
  • Stability of cable yarding with self-propelled carriage was discussed by theoretical tension calculation and field test. To verify usefulness of theoretical stability evaluation of cable yarding operation, skyline tension and stump anchoring force were measured and compared with theoretical calculation. As results, we know that measured skyline tension was similar to theoretical calculated tension. From these results, overall stability of cable logging operation could be evaluate. The stump anchoring force correlated closely with the stump diameters. The inclination angles that the stumps show the maximum anchoring force were ranged 5-10 degrees. It was conclude that the stumps have lost the function as an anchor when the inclinations was so large that they could be observed.

A Study on Development of Power Transfer Capability Calculation Algorithm Considering Voltage Stability Margin (전압안정도 여유를 고려한 수송능력산정 알고리즘의 개발에 관한 연구)

  • Kim, Yong-Ha;Lee, Bum;Moon, Hyuk-Ki;Jung, Hyun-Sung;Cho, Sung-Rin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.18-24
    • /
    • 2003
  • This paper presents a power transfer capability calculation algorithm considering voltage stability margin. In this method, voltage stability margin constraints are incorporated into a power transfer capability formulation to guarantee adequate voltage security levels in an interconnected power system The proposed method is applied to IEEE-24 reliability test systems and the results show the effectiveness of the method.