• 제목/요약/키워드: Square Wave Stripping

검색결과 53건 처리시간 0.02초

네모파 흡착 벗김 전압전류법에 의한 플루오로퀴놀론 계 항생제의 검출 (Determination of Fluoroquinolone Antibacterial Agents by Square Wave Adsorptive Stripping Voltammetry)

  • 부한길;송연주;박세진;정택동
    • 전기화학회지
    • /
    • 제13권1호
    • /
    • pp.63-69
    • /
    • 2010
  • 플루오로퀴놀론 계 항생제들의 전기화학적 거동을 카본 페이스트 전극 (carbon paste electrode ; CPE)을 사용하여 순환 전압전류법 (cyclic voltammetry)과 네모파 흡착 벗김 전압전류법 (square wave adsorptive stripping voltammetry)으로 연구하였다. Enrofloxacin (ENR), Norfloxacin (NOR), Ciprofloxacin (CIP), Ofloxacin (OFL), Levofloxacin (LEV) 등 5가지 플루오로퀴놀론 계 항생제에 대한 전기화학적 분석을 수행하였다. pH 4.5인 아세트산 완충 용액 (acetate buffer) 에서 플루오로퀴놀론 계 항생제의 산화 전위는 Ag/AgCl 기준 전극에 대하여 각각 ENR : 0.952V, NOR : 1.052 V, CIP : 1.055 V, OFL : 0.983 V, LEV : 0.990 V 의 값을 나타내었으며, 네모파 흡착 벗김 전압전류법에 의한 산화 전류는 $0.2\;{\mu}M$에서 $1\;{\mu}M$ 사이의 농도영역에서 각 항생제의 농도와 선형을 나타내었다.

Voltammetric Assay of Silver Ions in Frog's Tissue

  • Ly, Suw-Young;Lee, Jin-Hui;Lee, Chang-Hyun
    • 한국응용과학기술학회지
    • /
    • 제30권1호
    • /
    • pp.139-145
    • /
    • 2013
  • The electrochemical analysis of silver ion was performed using cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry, and electrode cell systems were fabricated with graphite pencil electrode (GE) of working, reference and counter electrodes. Also electrolyte was the use of sea water as electrolyte solutions instead of ionic controlled solutions. The optimum analytical conditions for the cyclic and stripping parameters were determined using GE. The results approached the microgram working ranges of SW(ug/L) and CV(ug/L) Ag, and the optimum conditions were applied to frog's tissue and the food samples.

FPGA SoC를 이용한 네모파 전압전류법의 주파수 변화에 따른 계측 분석 (Determination of Frequency for decision of heavy metal ion concentration in Square Wave Voltammetry with FPGA SoC)

  • 이재춘
    • 디지털산업정보학회논문지
    • /
    • 제14권4호
    • /
    • pp.101-107
    • /
    • 2018
  • In the stripping scan square wave voltammetry (SV+SWV) polarography that is often used to analyze the concentration of heavy metals in water, we must measure the point where the faradic current that flows by the pure oxidation-reduction reaction at the electrode is greater than the capacitive current, the frequency cannot be too high. Therefore we wanted to find the frequency range that can be measured. In order to do this, we came up with a method to analyze the signal using FPGA Soc. With this method, the frequency of the square wave was increased from 10Hz to 400Hz by 10Hz, and the measuring time of the square wave was changed from 96.695% to 96.765% by 0.005% while 1600 experiments were conducted. As a result, the frequency of the square wave maintained a stable area of potential-current within 320Hz and it was possible to measure the potential-current signal when calculating the measuring time within the frequency range of 96.7155%.

Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode

  • Ly, Suw-Young;Lee, Hyun-Kuy;Kwak, Kyu-Ju;Ko, Jun-Seok;Lee, Jeong-Jae;Cho, Jin-Hee;Kim, Ki-Hong;Kim, Min-Seok;Lee, So-Jung
    • Toxicological Research
    • /
    • 제24권3호
    • /
    • pp.227-233
    • /
    • 2008
  • To detect lead ions using electrochemical voltammetric analysis, Infrared Photo-Diode Electrode(IPDE) was applied via cyclic and square wave stripping voltammetry. Lead ions were deposited at 0.5 V(versus Ag/AgCl) accumulation potential. Instrumental measurements systems were made based on a simple and compact detection system. The stripping voltammetric and cyclic voltammetric optimal parameters were searched. The results yielded a cyclic range of $40{\sim}240mgl^{-1}$ Pb(II) and a square wave stripping working range of $0.5{\sim}5.00mgl^{-1}$ Pb(II). The relative standard deviation at 2 and 4 $mgl^{-1}$ Pb(II) was 0.04% and 0.02%(n=15), respectively, using the stripping voltammetric conditions. The detection limit was found to be 0.05 $mgl^{-1}$ with a 40 sec preconcentration time. Analytical interference ions were also evaluated. The proposed method was applied to determine lead ions in various samples.

Germanium(Ⅳ)-Morin 착물에 대한 네모파 양극벗김 전압전류법적 연구 (Square-Wave Anodic Stripping Voltammetric Study of Germanium(Ⅳ)-Morin Complex)

  • 손세철;박용준;조기수
    • 대한화학회지
    • /
    • 제41권11호
    • /
    • pp.590-593
    • /
    • 1997
  • Germanium(IV)-Morin 착물에 대한 네모파 양극벗김 전압전류법적 연구를 0.5 M 황산 지지전해질에서 수행하였다. Germanium(IV)-Morin 착물의 피크전위는 - 0.606 V vs. Ag/AgCl에서 나타났다. Germanium(IV)-Morin 착물의 피크전류 크기에 미치는 지지전해질의 황산 농도, Morin의 농도, 축적전위 및 축적시간의 의존성 등에 대하여 논의하였다. 또한, Germanium(IV)-Morin 착물의 피크전류 크기에 영향을 주는 금속 양이온들의 방해효과도 조사하였다. 이 방법을 적용시켜 축적시간을 60초로 하였을 때 Germanium(IV)의 검출한계는 $3.76{\times}10^{-7}M(27 {\mu}g/L)$ 이었으며, 0.4 mg/L($5.5{\times}10^{-6}$ M)의 Germanium(IV) 분석에 대한 상대표준편차(n=8)는 3.2% 이었다.

  • PDF

FPGA를 이용한 네모파 전압전류법의 계측시간 분석 (Determination of measuring time for decision of heavy metal ion concentration in Square Wave Voltammetry with FPGA)

  • 이재춘
    • 디지털산업정보학회논문지
    • /
    • 제12권4호
    • /
    • pp.25-31
    • /
    • 2016
  • In this research, to analyze the concentration of heavy metal ions in water, we tried to find the measuring time at which the faradaic electric currents flowing by the pure oxidation-reduction reaction from the pushing up mercury electrode of the stripping scan square wave voltammetry(SV+SWV) methods system becomes larger than the capacitance electric current. In order to do this, a method for analyzing signals using FPGA has been designed and we conducted 120 experiments using it. As a result, when the frequency of the square wave is 40Hz, The valid potential-current signal was measured from 96.6667% to 96.7155% of the end of the pulse of the forward and reverse, and the optimal signal was measured at 96.6667%. In addition, the experiment was carried out 40 times by changing the pulse height of the square wave from 10Mv to 40Mv. As a result, at a size smaller than 40Mv, there is little change in the magnitude of the potential-current, and an invalid signal was generated when it is out of this size.

DNA 고정 탄소나노튜브 페이스트전극의 물고기 세포속 테트라싸이클린에 정량 (Measuring Oxytetracycline Using a Simple Prepared DNA Immobilized on a Carbon Nanotube Paste Electrode in Fish Tissue)

  • 이수영;이장현;정영삼
    • 대한화학회지
    • /
    • 제51권5호
    • /
    • pp.412-417
    • /
    • 2007
  • DNA를 고정한 탄소나노튜브 페이스트 전극으로 옥시테트라싸이클린 항생제의 분석조건을 연구하였다. 사각 파형 벗김 전압전류법과 순환 전압 전류법을 사용하여 최적조건에서 1-10 ngL?1의 정량 가능 범위에 도달하였다. 벗김법 0.1 mgL?1 농도에서 15번 반복 측정하여 0.068%의 상대표준편차였으며, 벗김법 최적 분석 조건에서 0.4 ngL?1의 검출 한계를 얻었다. 개발된 결과를 양식어류의 세포에서 응용하였다.

국내산(國內産) 명일엽(明日葉)의 부위별 게르마늄 함량(含量) (Germanium(IV) Content in the Korean Angelica keiskei Koidz)

  • 정승일;한완수
    • 한국약용작물학회지
    • /
    • 제7권1호
    • /
    • pp.11-15
    • /
    • 1999
  • 국내에서 재배 수확되는 명일엽에 지역별, 부위별로 게르마늄 함량을 네모파 산화전극 벗김전압 전류법을 이용하여 조사한 결과 재배된 지역에 따라 게르마늄의 함량이 공시재료간 잎은 3.8배 정도, 줄기는 5배 정도였다. 명일옆(明日葉)의 채취부위별 게르마늄 함량은 잎부분에서 386ppm로 가장 높았으며 줄기에서 29ppm으로 13.3배 잎에서 더 높았다.

  • PDF

Integrated Microdisk Gold Electrode Modified with Metal-porphyrin and Metal-phthalocyanines for Nitric Oxide Determination in Biological Media

  • Kim, Il-Kwang;Bae, Hyun-Ok;Oh, Gi-Soo;Chung, Hun-Taeg;Kim, Young-Jin;Chun, Hyun-Ja
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권11호
    • /
    • pp.1579-1584
    • /
    • 2003
  • An integrated gold microdisk electrode was constructed and modified with metal-porphyrin or metal-phthalocyanines for NO determination in biological media. Microanalysis of NO using square wave anodic stripping voltammetry in $1\;{\times}\;10^{-2}$ M $HClO_4$ was optimal when the accumulation potential was 0.1 V, frequency 100 Hz, and the scan rate was 200 mV/s. When the electrode was modified with metal-porphyrin or metal-phthalocyanines, the anodic peak currents of NO increased due to the catalytic oxidation of NO. In case of Fe(II)-phthalocyanine modified electrode, the peak currents remarkably increased and the sensitivity was high. The calibration curve had good linearity in the range from $3.6\;{\times}\;10^{-5}$ M to $7.2\;{\times}\;10^{-7}$ M, and the detection limit was $5.7\;{\times}\;10^{-7}$ M. For the structural stability and increased sensitivity, Fe(II)-phthalocyanine modified gold microdisk electrode coated with Nafion was applied to determination of NO released from cultured macrophase.

Analysis of Cu in Mezcal Commercial Samples using Square Wave Anodic Stripping Voltammetry

  • Salinas, Gerardo;Ibanez, Jorge G.;Vasquez-Medrano, Ruben;Frontana-Uribe, Bernardo A.
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권4호
    • /
    • pp.276-281
    • /
    • 2018
  • High concentration of copper in mezcal, a representative Mexican spirituous alcoholic beverage, is a serious problem due to the damage that it may cause to human health. A cyclic voltammetry and square wave anodic stripping voltammetry study of copper (II) in three commercial mezcal samples based on glassy carbon electrode response was undertaken. The analysis was developed using a simulated matrix solution ($EtOH/H_2O$ (1:1), 0.1 M $LiClO_4$ and AcOH/AcONa 0.05 M/0.008 M), with Cu (II) concentrations in the range 0 - 1 ppm. Direct electrochemical analysis of mezcal samples was complicated by the presence of different organic compounds in the matrix. The analytical signal of Cu (II) in the spirituous was notably improved and the interferences caused by organic compounds were minimized, by diluting the mezcal samples 10% with $EtOH/H_2O$ (1:1) solution. An efficient quantification of Cu (II) was obtained from the calibration curve by the SWASV and using the internal standard method (Cd (II)) in commercial samples (1.2-6.7 ppm); the results were correlated satisfactorily with the values obtained by AAS.