• Title/Summary/Keyword: Spurious Energy

Search Result 64, Processing Time 0.022 seconds

A Linear Out-of-plane-deformable Curved Beam Element (면외 변형이 가능한 평면 곡선보의 선형 유한요소)

  • 김용우;문원주;권해성;민옥기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.419-429
    • /
    • 1992
  • 본 연구에서는 면외 변형이 가능한 평면 곡선보에 수정 형상함수를 적용하여 탈락성 및 지속성 에너지에 포함된 가성구속에 의한 수치해의 거동을 고찰함과 동시에, 가성구속에 의한 오차 발생 요인이 제거된, 면외 변형이 가능한 평면 곡선보의 선형 요소를 제안하고자 한다.

A Study on the Multiple Spurious Operation Analysis in Fire Events Probabilistic Safety Assessment of Domestic Nuclear Power Plant (국내 원자력발전소의 화재사건 확률론적안전성평가에서 다중오동작 분석 연구)

  • Kang, Dae Il;Jung, Yong Hun;Choi, Sun Yeong;Hwang, Mee-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.136-143
    • /
    • 2018
  • In this study, we conducted a pilot study on the multiple spurious operations (MSO) analysis in the fire probabilistic safety assessment (PSA) of domestic nuclear power plant (NPP) to identify the degree of influence of the operator actions used in the MSO mitigation strategies. The MSO scenario of the domestic reference NPP selected for this study is refueling water tank (RWT) drain down event. It could be caused by spurious operations of the containment spray system (CSS) of the reference NPP. The RWT drain down event can be stopped by the main control room (MCR) operator actions for stopping the operation of CSS pump or closing the CSS motor operated valve if the containment spray actuation signal (CSAS) is spuriously actuated. Outside the MCR, it can be stopped by operator actions for closing the CSS manual valves or motor operated valve or stopping the operation of CSS pump. The quantification result of a fire PSA model that takes into account all recovery actions for the RWT drain down event lead to risk reduction by about 95%, compared with quantification result of fire PSA model without considering them. Among the various operator actions, the recovery action for the spurious CSAS operations and the operator action for the manual valve are identified as the most important operator actions. This study quantitatively showed the extent to which the operator actions used as MSO countermeasures have affected the fire PSA quantification results. In addition, we can see the rank of importance among the operator recovery actions in quantitative terms.

Investigating spurious cracking in finite element models for concrete fracture

  • Gustavo Luz Xavier da Costa;Carlos Alberto Caldeira Brant;Magno Teixeira Mota;Rodolfo Giacomim Mendes de Andrade;Eduardo de Moraes Rego Fairbairn;Pierre Rossi
    • Computers and Concrete
    • /
    • v.31 no.2
    • /
    • pp.151-161
    • /
    • 2023
  • This paper presents an investigation of variables that cause spurious cracking in numerical modeling of concrete fracture. Spurious cracks appear due to the approximate nature of numerical modeling. They overestimate the dissipated energy, leading to divergent results with mesh refinement. This paper is limited to quasi-static loading regime, homogeneous models, cracking as the only nonlinear mode of deformation and cracking only due to tensile loading. Under these conditions, some variables that can be related to spurious cracking are: mesh alignment, ductility, crack band width, structure size, mesh refinement and load increment size. Case studies illustrate the effect of each variable and convergence analyses demonstrate that, after all, load-increment size is the most important variable. Theoretically, a sufficiently small load increment is able to eliminate or at least alleviate the detrimental influence of the other variables. Such load-increment size might be prohibitively small, rendering the simulation unfeasible. Hence, this paper proposes two alternatives. First, it is proposed an algorithm that automatically find such small load increment size automatically, which not necessarily avoid large computations. Then, it is proposed a double simulation technique, in which the crack is forced to propagate through the localization zone.

A function space approach to study rank deficiency and spurious modes in finite elements

  • Sangeeta, K.;Mukherjee, Somenath;Prathap, Gangan
    • Structural Engineering and Mechanics
    • /
    • v.21 no.5
    • /
    • pp.539-551
    • /
    • 2005
  • Finite elements based on isoparametric formulation are known to suffer spurious stiffness properties and corresponding stress oscillations, even when care is taken to ensure that completeness and continuity requirements are enforced. This occurs frequently when the physics of the problem requires multiple strain components to be defined. This kind of error, commonly known as locking, can be circumvented by using reduced integration techniques to evaluate the element stiffness matrices instead of the full integration that is mathematically prescribed. However, the reduced integration technique itself can have a further drawback - rank deficiency, which physically implies that spurious energy modes (e.g., hourglass modes) are introduced because of reduced integration. Such instability in an existing stiffness matrix is generally detected by means of an eigenvalue test. In this paper we show that a knowledge of the dimension of the solution space spanned by the column vectors of the strain-displacement matrix can be used to identify the instabilities arising in an element due to reduced/selective integration techniques a priori, without having to complete the element stiffness matrix formulation and then test for zero eigenvalues.

Extension of Field-Consistency to Plane Strain Elements (일관장 개념의 평면변형률 요소에의 확장)

  • 김용우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1799-1809
    • /
    • 1995
  • The applicability of the field-consistency paradigm, which was originally employed for analysis of locking due to constrained energy having the second power of a strain, is extended to the constrained energy having a quadratic form of strain. For the extension, nearly-incompressible plane strain problem is considered by introducing the concept of reduced minimization. The field-consistent analysis of the plane strain problem leads to a clear and systematic understanding on the relation amongst constraints imposed on element, spurious constraint -free optimal points, and integration order used.

Improvement of Finite Element for Mindlin Plate Bending (Mindlin 평판 유한요소의 개선)

  • 김선훈;최창근
    • Computational Structural Engineering
    • /
    • v.1 no.2
    • /
    • pp.83-90
    • /
    • 1988
  • The present work is concerned with the improvement of finite element for the analysis of plate bending structures. The element formulation is based upon Mindlin plate concept. The displacement field of this element is formed by adding nonconforming modes to two rotational displacement components of a 'heterosis plate element. The element has the requisite numbers of zero eigenvalues associated with rigid body modes to avoid the spurious zero energy mode. It is shown that the results obtained by the element converged to the exact solutions very rapidly as the mesh is refined and exhibited reliable solutions through numerical studies for standard benchmark problems. This element is shown to overcome the shear locking problem completely in very thin plate situation even for irregular meshes.

  • PDF

Analysis of multiple spurious operation scenarios of Korean PHWRs using guidelines of nuclear power plants in U.S.

  • Kim, Jaehwan;Jin, Sukyeong;Kim, Seongchan;Bae, Yeonkyoung
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1765-1775
    • /
    • 2019
  • Multiple spurious operations (MSOs) mean multiple fire induced circuit faults causing an undesired operation of one or more systems or components. The Nuclear Energy Institute (NEI) of the United States published NEI 00-01 as guidelines for solving MSOs. And this guideline includes MSO scenarios of pressurized water reactor (PWR) and boiling water reactor (BWR). Nuclear power plant operators in U.S. analyzed MSOs under MSO scenarios included in NEI 00-01 and operators of PWRs in Korea also analyzed MSOs under the scenarios of NEI 00-01. As there are no pressurized heavy water reactors (PHWRs) in the United States, MSO scenarios of PHWRs are not included in the NEI 00-01 and any feasible scenarios have not been developed. This paper developed MSO scenarios which can be applied to PHWRs by reviewing the 63 MSO scenarios included in NEI 00-01. This study found that seven scenarios out of the 63 MSO scenarios can be applied and three more scenarios need to be developed.

A Computer Program for 2-D Fluid-Structure-Soil Interaction Analysis (2차원 유체- 구조물-지반 상호작용해석 전산프로그램)

  • 김재민
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.427-434
    • /
    • 2000
  • This paper presents a computer program for a 2-D fluid-structure-soil interaction analysis. With this computer program the fluid can be modeled by a spurious free 4-node displacement-based fluid element which uses rotational penalty and mass projection technique in conjunction with the one point reduced integration scheme to remove the spurious zero energy modes. The structure and near field soil are discretized by the standard finite elements while the unbounded far field soil are discretized by the standard finite elements while the unbounded far field soil is represented by the frequency dependent dynamic infinite elements. Sine this method models directly the fluid-structure-soil system it can be applied to the dynamci analysis of 2-D liquid storage structure with complex geometry. For the purpose of verification dynamic analyses for tanks on a rigid foundation and on compliant embankment are carried out. Comparison of the present results with those by ANSYS program shows good agreement.

  • PDF

Earthquake Response Analysis for 2-D Fluid-Structure-Soil Systems (2차원 유체-구조뭍-지반계의 지진응답해석)

  • 윤정방;장수혁;김재민;홍선기
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.289-296
    • /
    • 2000
  • This paper presents a method of seismic analysis for a 2-D fluid-structure-soil interaction systems. With this method, the fluid can be modeled by spurious free 4-node displacement-based fluid elements which use rotational penalty and mass projection technique in conjunction with the one point reduced integration scheme to remove the spurious zero energy modes. The structure and the near-field soil are discretized by the standard 2-D finite elements, while the unbounded far-field soil is represented by the dynamic infinite elements in the frequency domain. Since this method directly models the fluid-structure-soil interaction systems, it can be applied to the dynamic analysis of a 2-D liquid storage structure with complex geometry. Finally, results of seismic analyses are presented for a spent fuel storage tank embedded in a layered half-space and a massive concrete dam on a layered half-space.

  • PDF

Earthquake Response Analysis for 2-D Fluid-Structure-Soil Systems (2차원 유체-구조물-지반계의 지진응답해석)

  • 윤정방;장수혁;김재민
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.132-137
    • /
    • 2001
  • This paper presents a method of seismic analysis for a 2-D fluid-structure-soil interaction systems. With this method, the fluid can be modeled by spurious free 4-node displacement-based fluid elements which use rotational penalty and mass projection technique in conjunction with the one point reduced integration scheme to remove the spurious zero energy modes. The structure and the near-field soil are discretized by the standard 2-D finite elements, while the unbounded far-field soil is represented by the dynamic infinite elements in the frequency domain. Since this method directly models the fluid-structure-soil interaction systems, it can be applied to the dynamic analysis of a 2-D liquid storage structure with complex geometry. Finally, results of seismic analyses are presented for a spent fuel storage tank embedded in a layered half-space and a massive concrete dam on a layered half-space.

  • PDF