• Title/Summary/Keyword: Spray transfer

Search Result 209, Processing Time 0.023 seconds

An Efficient Chloride Ingress Model for Long-Term Lifetime Assessment of Reinforced Concrete Structures Under Realistic Climate and Exposure Conditions

  • Nguyen, Phu Tho;Bastidas-Arteaga, Emilio;Amiri, Ouali;Soueidy, Charbel-Pierre El
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.2
    • /
    • pp.199-213
    • /
    • 2017
  • Chloride penetration is among the main causes of corrosion initiation in reinforced concrete (RC) structures producing premature degradations. Weather and exposure conditions directly affect chloride ingress mechanisms and therefore the operational service life and safety of RC structures. Consequently, comprehensive chloride ingress models are useful tools to estimate corrosion initiation risks and minimize maintenance costs for RC structures placed under chloride-contaminated environments. This paper first presents a coupled thermo-hydro-chemical model for predicting chloride penetration into concrete that accounts for realistic weather conditions. This complete numerical model takes into account multiple factors affecting chloride ingress such as diffusion, convection, chloride binding, ionic interaction, and concrete aging. Since the complete model could be computationally expensive for long-term assessment, this study also proposes model simplifications in order to reduce the computational cost. Long-term chloride assessments of complete and reduced models are compared for three locations in France (Brest, Strasbourg and Nice) characterized by different weather and exposure conditions (tidal zone, de-icing salts and salt spray). The comparative study indicates that the reduced model is computationally efficient and accurate for long-term chloride ingress modeling in comparison to the complete one. Given that long-term assessment requires larger climate databases, this research also studies how climate models may affect chloride ingress assessment. The results indicate that the selection of climate models as well as the considered training periods introduce significant errors for mid- and long- term chloride ingress assessment.

Design of Rotary Atomizer Using Characteristics of Thin Film Flow on Solid Surfaces (완전접촉 경계면 위의 박막유동 특성을 이용한 회전무화기의 형상 설계)

  • Park, Boo Seong;Kim, Bo Hung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.12
    • /
    • pp.1473-1482
    • /
    • 2013
  • A disc-type rotary atomizer affords advantages such as superior paint transfer efficiency, uniformity of paint pattern and particle size, and less consumption of compressed air compared to a spray-gun-type atomizer. Furthermore, it can be applied to all types of painting materials, and it is suitable for large-scale processes such as car painting. The painting quality, which is closely related to the atomizer performance, is determined by the uniformity and droplet size in accordance with the design of the bell disc surface. This study establishes the basics of how to design a surface by modeling the operating bell disc's RPM, diameter, surface angle, and film thickness considering dye characteristics such as the viscosity, density, and surface affinity.

Empirical Analysis on the Cooling Load and Evaporation Efficiency of Fogging System in Greenhouses (온실의 냉방부하 및 포그시스템의 증발효율 실험분석)

  • Nam, Sang-Woon;Seo, Dong-Uk;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • In order to develop the cooling load estimation method in the greenhouse, the cooling load calculation formula based on the heat balance method was constructed and verified by the actual cooling load measured in the fog cooling greenhouse. To examine the ventilation heat transfer in the cooling load calculation formula, we measured ventilation rates in the experimental greenhouse which a cooling system was not operated. The ventilation heat transfer by a heat balance method showed a relatively good agreement. Evaporation efficiencies of the two-fluid fogging system were a range of 0.3 to 0.94, average 0.67, and it showed that they increased as the ventilation rate increased. We measured thermal environments in a fog cooling greenhouse, and calculated cooling load by heat balance equation. Also we calculated evaporative cooling energy by measuring the sprayed amount in the fogging system. And by comparing those two results, we could verify that the calculated and the measured cooling load showed a relatively similar trend. When the cooling load was low, the measured value was slightly larger than calculated, when the cooling load was high, it has been found to be smaller than calculated. In designing the greenhouse cooling system, the capacity of cooling equipment is determined by the maximum cooling load. We have to consider the safety factor when installed capacity is estimated, so a cooling load calculation method presented in this study could be applied to the greenhouse environmental design.

Pest Control Effect using Unmanned Automatic Pesticide Spraying Device in Vegetable Greenhouse (시설채소 온실에서 무인 자동 약제 살포장치를 이용한 해충 방제효과)

  • Lee, Jung Sup;Lee, Jae Han;Bang, Ji Wong;Kim, Jin Hyun;Jang, Hye Sook
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.52-59
    • /
    • 2022
  • Pest control treatment was carried out using an unmanned automatic pesticide spraying system that can spray pesticides on crops while moving autonomously to control pests in vegetable greenhouse. As a result of examining the control effect on tomato and strawberry on thrips (Frankliniella occidentalis) and greenhouse whitefly (Trialeurodes vaporariorum) pests, 85.6% of yellow flower thrips were found in tomatoes and 87.5% in strawberries, and 81.7% (tomato) and 80.6% (strawberry) of greenhouse whitefly. In addition, the control effect according to the pesticide treatment method showed a control effect of 81.7% of the chemical spraying treatment by manpower and 83.9% of the automatic moving pesticide spraying treatment (F=22.1, p < 0.001). When comparing the control effect between the two treatment sections, there was no significance, but the automatic transfer spraying treatment showed a 2.2% higher effect. On the other hand, as a result of comparing the spraying time of the drug, the automatic unmanned control sprayer had a spraying time of 5 min/10a, which took about 25 min less than the conventional manpower spraying time of 25-30 min/10a. Based on these results, it was judged that the automatic transfer spraying method could be usefully used for efficient pest control in the facility greenhouse during the peak period of development.

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

FT-transgenic spray-type Chrysanthemum (Dendranthema grandiflorum Kitamura) showing early-flowering (FT 유전자 형질전환 스프레이 국화 (Dendranthema grandiflorum (Ramat.) Kitamura)의 조기개화성)

  • Lee, Su-Young;Han, Bong-Hee;Hur, Eun-Joo;Shin, Hak-Kee;Lee, Il-Ha;Lee, Eun-Kyung;Kim, Seung-Tae;Kim, Won-Hee;Kwon, O-Hyeon
    • Journal of Plant Biotechnology
    • /
    • v.39 no.3
    • /
    • pp.140-145
    • /
    • 2012
  • The flowering locus T (FT) gene, of which expression will be controlled at high temperature by heat shock promoter (it printed as to HSproFT), was introduced into spray-type chrysanthemum (Dendranthema grandiflorum (Ramat.) Kitamura) 2 cultivars ('Pink PangPang' and 'Pink Pride' by co-cultivation with Agrobacterium tumefaciens strain C58C1 harboring pCAMBIA2300 containing the HSproFT gene. After leaf segments of the 2 cultivars were infected with the A. tumafaciens with C58C1 as explants, shoots were regenerated from the explants cultured on the $1^{st}$ selection medium (MS basal salts + 1.0 mg/L BA, 0.5 mg/L IAA + 10 mg/L kanamycin + 0.7% plant agar, pH 5.8). The shoots were transferred into the $2^{nd}$ selection medium (MS basal salts + 1.0 mg/L BA, 0.5 mg/L IAA + 20 mg/L kanamycin + 0.7% plant agar, pH 5.8). One hundred seventeen plantlets from 'Pink PangPang' and 5 ones from 'Pink Pride' were confirmed as transformants by PCR analysis. Twenty six of the transformants and non-transformants were acclimatized and established well in a green house. Eights of 26 transgenic lines showed flower bud 1.7~10 days earlier than nontransgenic plants, and 24 of them flowered 1~6 days earlier than non- transgenic plants. The shape and color of flower of all HSproFT-transgenic lines were not different with those of non- transgenic plants.

Pesticide residues in chili pepper seeds and their transfer into the seed oil (고추씨 중 농약 잔류와 고추씨 기름으로 농약의 이행)

  • Lee, Mi-Gyung;Kim, Jong Seong
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.317-322
    • /
    • 2016
  • A pesticide mix solution containing difenoconazole, lambda-cyhalothrin, and lufenuron was applied 3 times on field grown chili pepper at a fivefold overdose dilution concentration of the spray solution at a pre-harvest interval of 7 day. Difenoconazole, lambda-cyhalothrin, and lufenuron were detected at 4.43, 0.334, and 1.56 mg/kg, respectively, in raw chili pepper. Washing with water reduced the residue levels to 91.4, 94.3, and 85.3%, respectively. In dried chili pepper, the residues of difenoconazole, lambda-cyhalothrin, and lufenuron were 22.2 mg/kg (processing factor, Pf =5.01), 1.65 mg/kg (Pf =4.94), and 6.54 mg/kg (Pf =4.19). In the seeds, difenoconazole and lambda-cyhalothrin were not detected, and lufenuron was detected at 0.0075 mg/kg (n=1) and <0.005 mg/kg (n=2). Thus the pesticide residues in the seeds was negligible. In the seed oil, difenoconazole and lufenuron residues were 0.0263 and 0.0295 mg/kg, respectively (concentration factors=5.26 and 4.72). These concentration factors supported the theoretical concentration factor of 6.8, assuming that all of compound present in the seed are transferred into the oil.

Development of Accident Response Information Sheets for Hydrogen Fluoride (불화수소에 대한 사고대응 정보시트 개발)

  • Yoon, Young Sam;Park, Yeon Shin;Kim, Ki Joon;Cho, Mun Sik;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • We analyzed the demand of competent authorities requiring adequate technical information for initial investigation of chemical accidents. Reflecting technical reports on chemical accident response by environmental agencies in the U.S. and Canada, we presented information on environmental diffusion and toxic effects available for the first chemical accident response. Hydrogen fluoride may have the risk potential to corrode metals and cause serious burns and eye damages. In case of inhalation or intake, it could have severe health effects. The substance itself is inflammable, but once heated, it decomposes producing corrosive and toxic fume. In case of contact with water, it can produce toxic, corrosive, flammable or explosive gases and its solution, a strong acid, may react fiercely with a base. In case of hydrogen fluoride leak, the preventive measures are to decrease steam generation in exposed sites, prevent the transfer of vapor cloud and promptly respond using inflammable substances including calcium carbonate, sodium bicarbonate, ground limestone, dried soil, dry sand, vermiculite, fly ash and powder cement. The method for fire fighting is to suppress fire with manless hose stanchions or monitor nozzles by wearing the whole body protective clothing equipped with over-pressure self-contained breathing apparatus from distance. In case of transport accident accompanied with fire, evacuation distance is 1,600m radius. In cae of fire, fire suppression needs to be performed using dry chemicals, CO2, water spray, water fog, and alcohol-resistance foam, etc. The major symptoms by exposure route are dyspnoea, bronchitis, chemical pneumonia and pulmonary edema for respiration, skin laceration, dermatitis, burn, frostbite and erythema for eyes, and nausea, diarrhea, stomachache, and tissue destruction for digestive organs. In atmosphere, its persistency is low, and its bioaccumulation in aquatic organism is also low.

Development of an Effective Method for Testing Resistance to Black Spot of Radish Caused by Alternaria brassicicola (Alternaria brassicicola에 의한 무 검은무늬병에 대한 효율적인 저항성 검정법 개발)

  • Lee, Ji Hyun;Jang, Kyoung Soo;Choi, Yong Ho;Kim, Hun;Choi, Gyung Ja
    • Horticultural Science & Technology
    • /
    • v.35 no.2
    • /
    • pp.210-219
    • /
    • 2017
  • This study was conducted to establish an efficient screening method for radish (Raphanus sativus) cultivars that are resistant to black spot, which is caused by Alternaria brassicicola. Seven A. brassicicola isolates were selected and investigated for their ability to produce spores and pathogenicity. Of these isolates, A. brassicicola KACC 40036 and 43923 produced abundant spores in V-8 juice agar medium and showed pathogenicity and strong virulence on radish seedlings. We examined the resistance of 61 commercial cultivars of radish to A. brassicicola KACC40036, and found that there are no highly resistant radish cultivars; however, some cultivars, such as 'Geumbong' and 'Searom', showed weak resistance to A. brassicicola. For further study, we selected four radish cultivars that showed different disease responses to A. brassicicola KACC40036. According to the growth stage of the radish seedlings, inoculum concentration, and incubation temperature of radish, development of black spot on four cultivars has been investigated. The results showed that younger seedlings were more sensitive to A. brassicicola than older seedlings, and the disease severity depended on the concentration of the spore suspension. The disease severity of plants incubated in humidity chamber at $25^{\circ}C$ was greater than that of plants grown at $20^{\circ}C$ or $30^{\circ}C$. Taken together, we suggest the following method for screening for radish plants that are resistant to A. brassicicola: 1) inoculate 16-day-old radish seedlings with an A. brassicicola spore suspension ($2.0{\times}10^5spores{\cdot}mL^{-1}$) using the spray method, 2) incubate the inoculated plants in a humidity chamber at $25^{\circ}C$ for 24 h and then transfer the plants to a growth chamber at $25^{\circ}C$ with 80% relative humidity under a 12 h light/dark cycle, and 3) assess the disease severity of the plants two days after inoculation.