• 제목/요약/키워드: Spot Scanning

검색결과 122건 처리시간 0.029초

다구찌법을 이용한 IR 레이저 Flip-chip 접합공정 최적화 연구 (A Study on the Optimization of IR Laser Flip-chip Bonding Process Using Taguchi Methods)

  • 송춘삼;지현식;김주한;김종형;안효석
    • Journal of Welding and Joining
    • /
    • 제26권3호
    • /
    • pp.30-36
    • /
    • 2008
  • A flip-chip bonding system using IR laser with a wavelength of 1064 nm was developed and associated process parameters were analyzed using Taguchi methods. An infrared laser beam is designed to transmit through a silicon chip and used for transferring laser energy directly to micro-bumps. This process has several advantages: minimized heat affect zone, fast bonding and good reliability in the microchip bonding interface. Approximately 50 % of the irradiated energy can be directly used for bonding the solder bumps with a few seconds of bonding time. A flip-chip with 120 solder bumps was used for this experiment and the composition of the solder bump was Sn3.0Ag0.5Cu. The main processing parameters for IR laser flip-chip bonding were laser power, scanning speed, a spot size and UBM thickness. Taguchi methods were applied for optimizing these four main processing parameters. The optimized bump shape and its shear force were modeled and the experimental results were compared with them. The analysis results indicate that the bump shape and its shear force are dominantly influenced by laser power and scanning speed over a laser spot size. In addition, various effects of processing parameters for IR laser flip-chip bonding are presented and discussed.

폭약 2,4,6-Trinitrotoluene에 노출된 분해세균 Stenotrophomonas sp. OK-5의 세포반응 (Cellular Responses of the TNT-degrading Bacterium, Stenotrophomonas sp. OK-5 to Explosive 2,4,6-Trinitrotoluene (TNT))

  • 장효원;송승열;김승일;강형일;오계헌*
    • 미생물학회지
    • /
    • 제38권4호
    • /
    • pp.247-253
    • /
    • 2002
  • 환경오염원으로서 폭약 2,4,6-trinitrotoluene (TNT)에 대한 TNT 분해세균 Stenotrophomonas sp. OK-5의 세포반응에 대하여 조사하였다. 아치사조건의 TNT농도와 노출시간에 따른 균주 OK-5의 생존율을 분석한 결과, 이 세균의 생존율은 스트레스 충격 단백질의 생성과 비례하였다. 총세포 지방산 조성분석에서 균주 OK-5는 tryp-ticase soy agar에서 자랄 때보다 TNT 배지에서 자랄 때 여러 가지 종류의 지방산이 생성되거나 사라지는 것이 밝혀졌다. 주사전자현미경하에서 TNT에 노출된 세포는 쭈글쭈글하고 불규칙적인 간상형으로 나타났다. Anti-DnaK와 anti-GroEL을 이용하여 SDS-PAGE와 Western blot을 통한 분석으로 균주 OK-5는 70 kDa DanK와 60 kDa GroEL을 포함하는 몇가지 스트레스충격단백질을 생성하는 것으로 밝혀졌다. TNT에 노출된 OK-5 배양에서 수용성 단백질 분획에 대하여 2-D PAGE를 실시하였으며, pH 3에서 pH 10의 범위에서 약 300여 개 spot들이 silver로 염색된 gel상에서 관찰되었다. 이들 가운데 TNT의 반응으로 현저하게 유도되고 발현된 10개의 spot들을 확인하였으며, 2개의 단백질, spot #1과 spot #10에 대한 내부아미노산 서열을 ESI-Q TOF로 분석한 결과, Xylella fastidiosa의 DnaK protein XF2340와 Mesorhizobium loti의 스트레스 유도단백질로 각각 밝혀졌다.

레이저 스폿의 칼날주사 방법에 의한 복사계 개구 면적의 정밀측정 (Precision measurements of radiometric aperture area by laser spot scanning along the edge of the aperture)

  • 강창호;김석원;박승남
    • 한국광학회지
    • /
    • 제15권3호
    • /
    • pp.258-262
    • /
    • 2004
  • 검출기의 분광감응도 표준으로부터 출발하여 SI 기본 단위의 하나인 칸델라(candela)눈금의 불확도는 복사계 개구의 면적 측정 불확도에 의해서 제한을 받는다. 칸델라 눈금을 새로 실현하기 위하여 다이아몬드 선삭가공기를 사용하여 개구의 가장자리가 칼날과 같도록 가공하였다. 이 개구를 디지털 되먹임 알고리듬을 채용한 x-y 이송대에 설치한 후, 출력이 안정화된 레이저 광선을 빔 허리가 5 $\mu\textrm{m}$ 이하가 되도록 집속시키고, 이송대를 이동하면서 개구의 가장자리 좌표를 칼날주사 방법으로 검출하였다. 이 좌표들을 지나는 최적의 타원을 최소 제곱법으로 결정하여 개구의 면적으로 구하였다. 측정 불확도를 분석한 결과 제작한 장치의 면적 측정의 상대 측정 표준 불확도(k=1)는 8${\times}$$10^{-5}$이다.

Photoresist 용융법을 이용한 미세렌즈 행렬 제작 (The Fabrication of Microlenses by Photoresist Melting Method)

  • 주영구;송현우;이용희;송석호
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.298-303
    • /
    • 1994
  • 두꺼운 Photoresist(PR)로 원기둥 모양을 만들고 이를 용융함으로써 미세렌즈 행렬을 제작하였다. 이 방법으로 직경 $25\mu\textrm{m}$, $50\mu\textrm{m}$, $100\mu\textrm{m}$의 렌즈를 만들고 전자주사현미경과 탐침형 표면측정기를 통해 그 모양을 확인하였다. 그리고 렌즈의 광학적 성능을 측정하기 위해 위상변이 간섭법을 사용하여 평행광의 렌즈 통과 후 파면을 구하였다. 여기서 기준 구면과의 파면오차를 구하여 렌즈 초점거리나 초점광도분포 등을 얻었다. 그 결과 직경 $100\mu\textrm{m}$, 초점거리 $164\mu\textrm{m}$의 미세렌즈는 초점의 spot 직경이 $25\mu\textrm{m}$보다 작은 것으로 측정되었다.

  • PDF

한국산 접목 선인장에서 분리한 괴사 반점 원인 바이러스의 생물리화학적 특성 (Purification and Biophysicochemical Properties of the Virus Causing Necrotic Spot Symptom on Korean Cactus)

  • 이철호;나용준;한정헌
    • 한국식물병리학회지
    • /
    • 제13권2호
    • /
    • pp.73-78
    • /
    • 1997
  • A virus was purified from Korean cactus (Chamaeaereus silverstrii f. Variegata Hort) showing necrotic spots and its biophysicochemical properties were examined. The typical necrotic spots were observed on healthy looking cactus inoculated with the purified virus and the various symptoms from necrotic spots to systemic were observed on 17 species of test plats used, which suggests that the purified virus has the normal infectivity and wide host range. Ultraviolet absorption scanning analysis revealed that the viral preparation had the typical curve with shoulder at 290 nm and its ratio of absorbances at 260 nm to 280 nm and extinction coefficient was 1.156 and 2.86, respectively. The virus represented one distinct and homogeneous band and molecular weight of viral coat protein was determined to 17, 000 Dalton by SDS-PAGE. The virus revealed rod-shaped virion (325$\times$20 nm) by electron microscopy. Based on these results, it has been thought that the virus purified in this study is the pathogenic agents causing necrotic spot symptom on Korean cacuts and one of the member of tobamovirus family.

  • PDF

As과 Ga 빔 조사에 의해 세척된 Si(100) 기판 위에 GaAs 에피층 성장과 RHEED 패턴 (GaAs Epilayer Growth on Si(100) Substrates Cleaned by As/Ga Beam and Its RHEED Patterns)

  • 임광국;김민수;임재영
    • 한국표면공학회지
    • /
    • 제43권4호
    • /
    • pp.170-175
    • /
    • 2010
  • The GaAs epitaxial layers were grown on Si(100) substrates by molecular beam epitaxy(MBE) using the two-step method. The Si(100) substrates were cleaned with different surface cleaning method of vacuum heating, As-beam, and Ga-beam at the substrate temperature of $800^{\circ}C$. Growth temperature and thickness of the GaAs epitaxial layer were $800^{\circ}C$ and 1 ${\mu}m$, respectively. The surface structure and epitaxial growth were observed by reflection high-energy electron diffraction(RHEED) and scanning electron microscope(SEM). Just surface structure of the Si(100) substrate cleaned by Ga-beam at $800^{\circ}C$ shows double domain ($2{\times}1$). RHEED patterns of the GaAs epitaxial layers grown on Si(100) substrates with cleaning method of vacuum heating, As-beam, and Ga-beam show spot-like, ($2{\times}4$) with spot, and clear ($2{\times}4$). From SEM, it is found that the GaAs epitaxial layers grown on Si(100) substrates with Ga-beam cleaning has a high quality.

Modification of surface pretreatment of white spot lesions to improve the safety and efficacy of resin infiltration

  • Yim, Hyun-Kyung;Min, Ji-Hyun;Kwon, Ho-Keun;Kim, Baek-Il
    • 대한치과교정학회지
    • /
    • 제44권4호
    • /
    • pp.195-202
    • /
    • 2014
  • Objective: A low-viscosity resin (infiltrant) was used to inhibit the progression of white spot lesions (WSLs) and resolve associated esthetic issues. An alternative pretreatment was explored to increase the pore volume of the surface layer of the WSLs. Also, the penetration effects of the infiltrant were evaluated for various pretreatments. Methods: Sixty two artificial lesions were fabricated on bovine teeth. As a positive control, 15% HCl gel was applied for 120 seconds. Further, 37% $H_3PO_4$ gel was applied for 30 seconds using three methods. The samples were divided as follows: $H_3PO_4$ only group, $H_3PO_4$ sponge group, and $H_3PO_4$ brush group. The acid was gently rubbed with the applicators (i.e., a sponge or brush) throughout the application time. To compare the effects of resin infiltration, twenty paired halves of specimens were treated with an infiltrant (ICON$^{(R)}$). Results: Thicknesses of the removed surface layers and infiltrated areas were evaluated by confocal laser scanning microscope. The positive control and the 37% $H_3PO_4$ brush group failed to show significant differences in the removed thickness (p > 0.05); however, the mean percentage of the infiltrated area was higher in the 37% $H_3PO_4$ brush group ($84.13{\pm}7.58%$%) than the positive control ($63.51{\pm}7.62%$, p < 0.001). Scanning electron microscope observations indicate higher pore volumes for the 37% $H_3PO_4$ brush group than for the positive control. Conclusions: Application of 37% $H_3PO_4$ with a brush for 30 seconds increased the pore volume of WSL surface layers and the percentage of infiltrated areas in comparison to the use of 15% HCl for 120 seconds.

Focused Electrospray Deposition for Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

  • Jeong, Kyung-Hwan;Seo, Jong-Cheol;Yoon, Hye-Joo;Shin, Seung-Koo
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권8호
    • /
    • pp.2293-2298
    • /
    • 2010
  • Focused electrospray (FES) deposition method is presented for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. FES ion optics consists of two cylindrical focusing electrodes capped with a truncated conical electrode through which an electrospray emitter passes along the cylindrical axis. A spray of charged droplets is focused onto a sample well on a MALDI target plate under atmospheric pressure. The shape and size distributions of matrix crystals are visualized by scanning electron microscope and the mass spectra are obtained by time-of-flight mass spectrometry. Angiotensin II, bradykinin, and substance P are used as test samples, while $\alpha$-cyano-4-hydroxycinnamic acid and dihydroxybenzoic acid are employed as matrices. FES of a sample/matrix mixture produces fine crystal grains on a 1-3 mm spot and reproducibly yields the mass spectra with little shot-to-shot and spot-to-spot variations. Although FES greatly stabilizes the signals, the space charge due to matrix ions limits the detection sensitivity of peptides. To avoid the space charge problem, we adopted a dual FES/FES mode, which separately deposits matrix and sample by FES in sequence. The dual FES/FES mode reaches the detection sensitivity of 0.88 amol, enabling ultrasensitive of peptides by homogeneously depositing matrix and sample under atmospheric pressure.

MDCT 장치의 z-축 기하학적 선량효율에 관한 연구 (Research of z-axis geometric dose efficiency in multi-detector computed tomography)

  • 김유현;김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.167-175
    • /
    • 2006
  • 최근의 나선형 CT와 MDCT는 기존의 고식적 CT보다 X-선 조사시의 겹침 현상과 영상 재구성에 있어서의 보간삽입처리로 인해 보다 높은 선량을 환자에게 주게 되었다. MDCT와 나선형 CT장치가 보다 많은 의학적 정보를 제공하는 것에도 불구하고 환자가 받는 방사선 노출은 기존의 고식적 CT검사에 비해 $2{\sim}4$배 정도로 증가되고 있는 실정이므로, 그 잠재적 위험성을 아무리 강조해도 지나침이 없다. CT장치에서의 보다 많은 X-선에 관련된 자료들, 특히 선량효율적 디자인이나 X-선 조절 소프트웨어에 대한 자료들이 필요하다. 왜냐하면 CT장치의 디자인 요소는 임상적 진단에 있어서 환자선량을 성공적으로 줄일 수 있는 중요한 요소이기 때문이다. 이에 본 연구에서는 최근 급격히 확산되어 사용되고 있는 여러 단계의 MDCT의 z-축 선량효율을 측정하여 SDCT와 비교하였다. 그리고 MDCT에서 스캔 시 채택하는 focal spot size와 beam collimation, 검출기 조합 등을 비롯한 파라메터들의 변화에 따른 z-축 선량효율을 파악하여 다음과 같은 결과를 얻었다. 1. SDCT가 z-축 기하학적 선량효율이 가장 높았고, 4 슬라이스 MDCT가 가장 낮았다. MDCT 중에서는 small beam collimation 적용 시 64 MDCT가 기하학적 선량효율이 가장 높았고 16, 8, 4 슬라이스 MDCT 순이었으며, large beam collimation 적용 시에는 small focal spot에서는 8 MDCT가, large focal spot에서는 16 MDCT가 가장 높았다. 2. MDCT의 경우 large focal spot에 비해 small focal spot의 z-축 기하학적 선량효율이 최저 0.67%에서 최대 13.62%의 범위에서 높았다. 3. MDCT의 경우 small beam collimation에 비해 large beam collimation의 z-축 기하학적 선량효율이 $3.13{\sim}51.52%$의 범위에서 높았다. 4. 동일한 focal spot size와 beam collimation을 채택한 상태에서 detector combination 차이에 따른 z-축 기하학적 선량효율은 4 슬라이스 MDCT의 모든 경우와 8 슬라이스 MDCT의 large beam collimation에서 일정하였다. 하지만 8 슬라이스 MDCT의 small beam collimation과 16 슬라이스 MDCT에서는 z-축 기하학적 선량효율이 차이를 보였으며 변화의 일률성은 없었다. 5. 동일한 스캔 파라메터를 적용시 나선형 스캔과 고식적 스캔 모드의 z-축 기하학적 선량효율은 동일하였으며, pitch를 변화시키거나 영상재구성 시 슬라이스 두께와 간격을 변화시켜도 z-축 기하학적 선량효율은 변화가 없었다. 결론적으로, CT검사 시 환자가 받는 X-선 피폭선량을 줄이기 위해 연구자는 CT장치의 선량효율에 대해 각별히 주의하여야 하며, Z-축 선량효율성을 높이는 동시에 최적의 임상적 정보를 보존할 수 있는 스캔 파라메터를 선택하여야 한다.

  • PDF

Study on effective band of advanced microwave scanning radiometer (AMSR) for observing first year sea ice in the Okhotsk Sea by airborne microwave radiometer (AMR)

  • Nakayama, Masashige;Nishio, Fumihiko;Tanikawa, Tomonori;Cho, Kohei;Shimoda, Haruhisa
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.456-461
    • /
    • 1999
  • It is very important for monitoring the interannual variability of sea ice extents in the Okhotsk Sea because the global warming has firstly appeared around the Okhotsk Sea, locating around the southernmost region of sea ice cover in the Northern Hemisphere. In order to develop the sea ice concentration algorithm by microwave sensors onboard satellite, electromagnetic properties of sea ice in the Okhotsk Sea, therefore, were observed by airborne microwave radiometer (AMR), which has the same frequencies as AMSR (Advanced Microwave Scanning Radiometer), ADEOS-II, launching on November, 2000. On this study, it is discussed how to make the image of AMR-EFOV and the video image with nadir angle under flight at the same time, and superimpose the brightness temperature data by AMR-EFOV on the video mosaiced images. For comparing SPOT image, it is clearly that the variation of brightness temperature is small in 89GHz V-pol without the sea ice types and increase at the lower frequency-band.

  • PDF