• 제목/요약/키워드: Spiral vortex flow

검색결과 22건 처리시간 0.027초

치수효과를 고려한 횡류홴의 작동특성연구 (A Study on the Operational Characteristic with the Scale Effect of the Cross-Flow Fan)

  • 김형섭;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.583-589
    • /
    • 2004
  • One of noticeable features in the cross flow fan is that a working fluid passes through impeller blade twice without distinction between the inlet and exit angles. Also, it does produce higher circumferential velocity than other types of blade at the same flow rate in accordance with the application of the forward curved shape. However, a design theory for the cross-flow fan has not yet been formed owing to an eccentric vortex, which is the remarkable characteristics, occurred in a cross-flow fan. Furthermore, the eccentric vortex, which is difficult to control of the size and position, is the important cause of performance decrease. In this study, experiments are carried out to estimate the similarity of the cross-flow fan with various scales and rotational velocity changes. Pressure coefficients to flow coefficients with various scales of the cross-flow fan are plotted to research the application of the general similarity law of the turbomachinery in the cross-flow fan with Archimedes spital, which is the important factor haying an effect on it.

  • PDF

수리실험을 이용한 지하유입시설 유입구 형상에 따른 수리학적 특성 분석 (Study of Hydraulic Characteristics with the Shape of the Intake of an Underground Inflow Facility using Hydraulic Experiments)

  • 성호제;박인환;이동섭
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.119-126
    • /
    • 2018
  • In recent years, as flood damage caused by heavy rains increased, the great-depth tunnel using urban underground space is emerging as a countermeasure of urban inundation. The great-depth tunnel is used to reduce urban inundation by using the underground space. The drainage efficiency of great-depth tunnel depends on the intake design, which leads to increase discharge into the underground space. The spiral intake and the tangential intake are commonly used for the inlet facility. The spiral intake creates a vortex flow along the drop shaft and reduces an energy of the flow by the wall friction. In the tangential intake, flow simply falls down into the drop shaft, and the design is simple to construct compared to the spiral intake. In the case of the spiral intake, the water level at the drop shaft entrance is risen due to the chocking induced by the flowrate increase. The drainage efficiency of the tangential intake decreases because the flow is not sufficiently accelerated under low flow conditions. Therefore, to compensate disadvantages of the previously suggested intake design, the multi-stage intake was developed which can stably withdraw water even under a low flow rate below the design flow rate. The hydraulic characteristics in the multi-stage intake were analyzed by changing the flow rate to compare the drainage performance according to the intake design. From the measurements, the drainage efficiency was improved in both the low and high flow rate conditions when the multi-stage inlet was employed.

대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구 (An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube)

  • 황승식
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

전산 유체 역학(CFD)을 이용한 원형 양식 사육 수조 내부 유동장 해석 (Analysis of land-based circular aquaculture tank flow field using computational fluid dynamics (CFD) simulation)

  • 권인영;김태호
    • 수산해양기술연구
    • /
    • 제56권4호
    • /
    • pp.395-406
    • /
    • 2020
  • The objectives of this study were to develop the optimal structures of recirculating aquaculture tank for improving the removal efficiency of solid materials and maintaining water quality conditions. Flow analysis was performed using the CFD (computational fluid dynamics) method to understand the hydrodynamic characteristics of the circular tank according to the angle of inclination in the tank bottom (0°, 1.5° and 3°), circulating water inflow method (underwater, horizontal nozzle, vertical nozzle and combination nozzle) and the number of inlets. As the angle in tank bottom increased, the vortex inside the tank decreased, resulting in a constant flow. In the case of the vertical nozzle type, the eddy flow in the tank was greatly improved. The vertical nozzle type showed excellent flow such as constant flow velocity distribution and uniform streamline. The combination nozzle type also showed an internal spiral flow, but the vortex reduction effect was less than the vertical nozzle type. As the number of inlets in the tank increased, problems such as speed reduction were compensated, resulting in uniform fluid flow.

고낙차 펌프-터빈에서의 축계 진동 특성 (Characteristics of the Shaft Vibration in a High Head Pump-Turbine)

  • 하현천;최성필
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.27-31
    • /
    • 1999
  • This paper describes the shaft vibration phenomena measured on a pump-turbine of a pumped storage power plant. The pump-turbine runs at a rotational speed of 450 rpm (7.5 Hz). The power output (load) of the pump-turbine is varied from 100 to 300 MW in the generating mode. The magnitude of the shaft vibration highly depends on the power load. The vibration magnitude of the shaft is very high in the middle load zone from 170 to 210 MW, elsewhere the vibration is low. From nitration spectra, it is shown that the frequency of major nitration in that load zone is 2.5 Hz which is approximately $34\%$ of the shaft rotating speed in Hz. This frequency component does not occur below and above that load zone. This subsynchronous vibration is caused by the flow induced disturbance due to spiral vortex flow downstream of the pump-turbine runner. Furthermore, the shaft vibration is highly decreased due to an increased bearing preload.

  • PDF

Tip Clearance Losses - A Physical Based Scaling Method

  • Pelz, Peter F.;Karstadt, Sascha
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.279-284
    • /
    • 2010
  • Tip clearance losses occur in every turbomachine. To estimate the losses in efficiency it is important to understand the mechanism of this secondary flow. Tip clearance losses are mainly caused by a spiral vortex formed on the suction side of the blade of a turbomachine, which induces a drag and also has an influence on the incident flow of the blades. In this paper a physical based scaling method is developed out of an analytical ansatz for the tip clearance losses. This scaling method is validated by measurements on an axial fan with five different tip clearances.

접선식 및 다단식 나선 유입구 흐름 특성의 실험적 연구 (An experimental investigation of flow characteristics in the tangential and the multi-stage spiral inlets)

  • 성호제;이동섭;박인환
    • 한국수자원학회논문집
    • /
    • 제52권3호
    • /
    • pp.227-234
    • /
    • 2019
  • 급격한 도시화와 산업화로 도심 재난 취약성이 증가하고, 전 세계적인 기후변화로 인한 극한 강우사상의 발생빈도가 증가하고 있다. 기존 방재시설의 용량한계를 넘어선 극한 강우사상의 발생으로 도심 지역의 침수피해 또한 증가하고 있다. 도심 침수피해를 예방하기 위해 지하공간을 활용한 지하저류 시설과 지하배수터널 활용이 급부상하고 있으며, 강우가 유입되는 지하유입구에 대한 수리학적 검토를 통한 성능 분석이 중요하다. 본 연구에서는 지하 유입구로 활용되고 있는 접선식(tangential) 유입구와 나선식(spiral) 유입구에 대해 유입유량 변화에 따른 유입부 수위를 계측하고 흐름 특성 변화를 분석했다. 나선식 유입구의 경우, 저유량 조건에서의 와류 유도 효과를 개선하기 위해 유입부 바닥면에 계단형 다단식 구조를 도입했다. 접선식 유입구에서는 고유량 유입조건 아래 도수(hydraulic jump)가 발생하며 유량 배제 효과가 급격하게 감소했다. 다단식 나선(multi-stage) 유입구의 경우, 접선식 유입구보다 유입유량 증가에 따른 수위 상승률은 높지만 저유량 및 고유량 유입조건에 대해 안정적인 유량 배제 효과를 유지했다. 또한, 실험에서 사용된 유입구 모형이 활용될 수 있도록 접선식 유입구와 다단식 나선 유입구 모형에 대한 수위-유량 관계 실험식(empirical formula)을 제시했다.

An Outlook on the Draft-Tube-Surge Study

  • Nishi, Michihiro;Liu, Shuhong
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권1호
    • /
    • pp.33-48
    • /
    • 2013
  • If large pressure fluctuation is observed in the draft tube of a Francis turbine at part-load operation, we have generally called it draft-tube-surge. As occurrence of this phenomenon seriously affects the limit of turbine operating range, extensive studies on the surge have been made since proposal of surge-frequency criterion given by Rheingans. According to the literature survey of related topics in recent IAHR symposiums on hydraulic machinery and systems, in which state-of-the-art contributions were mainly presented, a certain review of them may be desirable for an outlook on the future studies in this research field. Thus, in this review paper, the authors' previous attempts for the last three decades to challenge the following topics: a rational method for component test of a draft tube, nature of spiral vortex rope and its behavior in a draft tube and cavitation characteristics of pressure fluctuations, are introduced together with other related contributions, expecting that more useful and significant studies will be accomplished in the future.

와류감쇠 및 저항저감형 나선형 해양 구조물 주위 유동 LES 해석 (Large Eddy Simulation of Flow around Twisted Offshore Structure with Drag Reduction and Vortex Suppression)

  • 정재환;윤현식;최창영;전호환;박동우
    • 대한조선학회논문집
    • /
    • 제49권5호
    • /
    • pp.440-446
    • /
    • 2012
  • A twisted cylinder has been newly designed by rotating the elliptic cross section along the spanwise direction in order to reduce the drag and vorticies in wake region. The flow around the twisted cylinder at a subcritical Reynolds number (Re) of 3000 is investigated to analyze the effect of twisted spiral pattern on the drag reduction and vortex suppression using large eddy simulation (LES). The instantaneous wake structures of the twisted cylinder are compared with those of a circular and a wavy cylinder at the same Re. The shear layer of the twisted cylinder covering the recirculation region is more elongated than that of the circular and the wavy cylinder. Successively, vortex shedding of the twisted cylinder is considerably suppressed, compared with those of the circular and the wavy cylinder. Consequently, the mean drag coefficient and the fluctuating lift of the twisted cylinder are less than those of the circular and the wavy cylinder.

고낙차 펌프-터빈에서의 축계 진동 특성 (Characteristics of the Shaft Vibration in a High Head Pump-Turbine)

  • 하현천;최성필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.166-172
    • /
    • 1998
  • This paper describes the shaft vibration phenomena measured on a pump-turbine ofa pumped storage power plant. The pump-turbine runs at a rotational speed of 450 rpm (7.5 Hz). The power output (load) of the pump-turbine was varied from 100 to 300 MW in the generating mode. It was found that the magnitude of the shaft vibration was highly dependent upon the power load. The vibration magnitude of the shaft vibration is very high in the middle load zone from 170 to 210 MW, elsewhere the vibration low. From vibration spectra, it was found that the frequency of major vibration in that load zone was 2.5 Hz which is approximately $34\%$ of the shaft rotating speed in Hz. This frequency component disappeared below and above that load zone. This subsynchronous vibration is caused by the flow induced disturbance due to spiral vortex flow downstream of the pump-turbine runner. Furthermore, it was found that shaft vibration was highly decreased due to the increase of bearing preload.

  • PDF