• 제목/요약/키워드: Speed-power performance

검색결과 2,355건 처리시간 0.033초

50kW 풍력발전기의 출력 성능에 관한 연구 (A study of Power Performance for 50kW Wind Turbine)

  • 김형길;공정식;권기진;오진훈;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1068-1069
    • /
    • 2015
  • Wind turbines have an enormous potential for decentralized electricity generation. In recent years, there has been an increasing worldwide interest in small/medium wind systems. This paper presents the results of power performance testing conducted on a 50 kW turbine located in Yeonggwang test-bed. The turbine system is a pitch, active yaw, variable speed, upwind, three blade with a direct drive PMSG. This thesis covers the operation of variable speed wind turbines with pitch-yaw control. The system considered is controlled to generate maximum energy while minimizing loads. The data include power, wind speed, and direction from meteorological towers, and nacelle anemometer readings and output from turbine. The analysis concentrates on the effect of the load on the power-wind speed curve of the turbine.

  • PDF

소수력 발전설비 성능평가 시스템 구축 (Construction of small hydropower facilities performance evaluation system)

  • 김영준;김용열;조용;고재명
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.193.2-193.2
    • /
    • 2010
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

소수력 발전설비 성능평가 시스템 구축 (Construction of small hydropower facilities performance evaluation system)

  • 김영준;조용;고재명
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.206.2-206.2
    • /
    • 2011
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

Power Regulation of Variable Speed Wind Turbines using Pitch Control based on Disturbance Observer

  • Joo, Young-Jun;Back, Ju-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.273-280
    • /
    • 2012
  • Most variable speed wind turbines have pitch control mechanisms and one of their objectives is to protect turbines when the wind speed is too high. By adjusting pitch angles of wind turbine, the inlet power and the torque developed by the turbine are regulated. In this paper, the difference between the real wind speed and its rated value is regarded as a disturbance, and a component called disturbance observer (DOB) is added to the pre-designed control loop. The additional DOB based controller estimates the disturbance and generates a compensating signal to suppress the effect of disturbance on the system. As a result, the stability and the performance of the closed loop system guaranteed by an outer-loop controller (designed for a nominal system without taking into account of disturbances) are approximately recovered in the steady state. Simulation results are presented to verify the performance of the proposed control scheme.

가변 풍력발전 시스템의 최대출력 제어를 위한 Fuzzy 제어기 설계 (A Fuzzy Logic Controller Design for Maximum Power Extraction of Variable Speed Wind Energy Conversion System)

  • 김재곤;허욱열;김병륜
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권11호
    • /
    • pp.753-759
    • /
    • 2004
  • This paper presents a modeling and simulation of a fuzzy controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

Reconfigurable Multi-Array Architecture for Low-Power and High-Speed Embedded Systems

  • Kim, Yoon-Jin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제11권3호
    • /
    • pp.207-220
    • /
    • 2011
  • Coarse-grained reconfigurable architecture (CGRA) based embedded systems aims to achieve high system performance with sufficient flexibility to map a variety of applications. However, the CGRA has been considered as prohibitive one due to its significant area/power overhead and performance bottleneck. In this work, I propose reconfigurable multi-array architecture to reduce power/area and enhance performance in configurable embedded systems. The CGRA-based embedded systems that consist of hierarchical configurable computing arrays with varying size and communication speed were examined for multimedia and other applications. Experimental results show that the proposed approach reduces on-chip area by 22%, execution time by up to 72% and reduces power consumption by up to 55% when compared with the conventional CGRA-based architectures.

고속 전력선통신 시스템의 터보 부호화 (Turbo Coded OFDM Scheme for a High-Speed Power Line Communication)

  • 이재선;김요철;김정휘;김진영
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.190-196
    • /
    • 2009
  • In this paper, performance of a turbo-coded OFDM system is analyzed and simulated in a power line communication channel. Since the power line communication system typically operates in a hostile environment, turbo code has been employed to enhance reliability of transmitted data. The performance is evaluated in terms of bit error probability. As turbo decoding algorithms, MAP (maximum a posteriori), Max-Log-MAP, and SOVA (soft decision Viterbi output) algorithms are chosen and their performances are compared. From simulation results, it is demonstrated that Max-Log-MAP algorithm is promising in terms of performance and complexity. It is shown that performance is substantially improved by increasing the number of iterations and interleaver length of a turbo encoder. The results in this paper can be applied to OFDM-based high-speed power line communication systems.

  • PDF

2K-HII차동기어 결합형 무단변속기의 성능해석 (Performance Analysis of CVTs with a 2K-H II Differential Gear)

  • 박재민;김연수;최상훈
    • 한국정밀공학회지
    • /
    • 제21권4호
    • /
    • pp.170-178
    • /
    • 2004
  • Continuously variable transmission (CVT) mechanisms considered here are input coupled types that combine the functions of a 2K-H II type differential gear and a V-belt type continuously variable unit (CVU). For the 8 different mechanisms, 4 of them are power-circulation modes while the other 4 are power-split modes, various performance analysis (speed ratios, power flows, divisions of power transmission in a differential gear and a CVU, and theoretical efficiencies) are performed to vary design parameters. Experimental studies are executed to validate fundamental relations (speed ratios, power flows, efficiencies, occurrence of geared neutral). Some useful characteristics associated with performance also are discussed in the mechanisms.

Modeling and experimental comparative analysis on the performance of small-scale wind turbines

  • Basta, Ehab;Ghommem, Mehdi;Romdhane, Lotfi;Abdelkefi, Abdessattar
    • Wind and Structures
    • /
    • 제30권3호
    • /
    • pp.261-273
    • /
    • 2020
  • This paper deals with the design, wind tunnel testing, and performance analysis of small wind turbines targeting low-power applications. Three different small-size blade designs in terms of size, shape, and twisting angle are considered and tested. We conduct wind tunnel tests while measuring the angular speed of the rotating blades, the generated voltage, and the current under varying resistive loading and air flow conditions. An electromechanical model is also used to predict the measured voltage and power and verify their consistency and repeatability. The measurements are found in qualitative agreement with those reported in previously-published experimental works. We present a novel methodology to estimate the mechanical torque applied to the wind turbine without the deployment of a torque measuring device. This method can be used to determine the power coefficient at a given air speed, which constitutes an important performance indicator of wind turbines. The wind tunnel tests revealed the capability of the developed wind turbines to deliver more than 1225 mW when subject to an air flow with a speed of 7 m/s. The power coefficient is found ranging between 26% and 32%. This demonstrates the aerodynamic capability of the designed blades to extract power from the wind.

A Novel Filtering Method Based on a Nonlinear Tracking Differentiator for the Speed Measurement of Direct-drive Permanent Magnet Traction Machines

  • Wang, Gaolin;Wang, Bowen;Zhao, Nannan;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.358-367
    • /
    • 2017
  • This paper presents a novel filtering method for speed measurements to improve the low-speed performance of the direct-drive permanent magnet traction machines for elevators. Based on the theory of nonlinear tracking differentiator (NTD), this method, which can act as a high performance filter of a raw speed signal, obtains a more accurate speed feedback signal when applying a low-resolution encoder. In addition, it can relieve the interference caused by the position derivative for speed sampling. By analyzing the frequency response of the NTD, the influence of its parameters on the performance of the speed filtering is investigated. Compared with different types of low-pass filters, the proposed method shows a shorter time delay and a stronger ability in terms of noise suppression when the parameters are selected carefully. In addition, when using the measured speed signal through a nonlinear tracking differentiator as the feedback of the system, the motor runs more steadily at low speeds. As a result, the riding comfort of a direct-drive elevator can be improved. The feasibility of the proposed strategy was verified on an 11.7kW elevator traction machine using a commercial inverter.