• Title/Summary/Keyword: Spectral range

Search Result 957, Processing Time 0.025 seconds

On the Estimation Techniques of Hurst exponent (허스트 지수 산정 방법에 대한 고찰)

  • Kim, Byung-Sik;Kim, Hung-Soo;Seoh, Byung-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.12
    • /
    • pp.993-1007
    • /
    • 2004
  • There are many different techniques for the estimation of the Hurst exponent. However, the techniques can produce different characteristics for the persistence of a time series each other. This study uses several techniques such as adjusted range, resealed range(RR) analysis, modified restated range(MRR) analysis, 1/f power spectral density analysis, Maximum Likelihood Estimation(MLE), detrended fluctuations analysis(DFA), and aggregated variance time(AVT)method for the Hurst exponent estimation. The generated time series from chaos and stochastic systems are analyzed for the comparative study of the techniques. Then this study discusses the advantages and disadvantages of the techniques and also the limitations of them.

A Helicopter-borne Pulse Doppler Radar Signal Processor Development using High Speed Multi-DSP (고속 Multi-DSP를 이용한 헬기탑재 펄스 도플러 레이다 신호처리기 개발)

  • Kwag, Young-Kil;Choi, Min-Su;Jeun, In-Pyung;Hwang, Gwang-Yeon;Lee, Kang-Hoon;Lee, Jae-Ho
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.23-28
    • /
    • 2005
  • An airborne radar is an essential aviation electronic system of the helicopter to perform various missions in all-weather environments. This paper presents the results of the design and implementation of the airborne pulse doppler radar signal processor using high multi-DSP for the multi-function radar capability such as short-range, midium-range, and long-range depending on the mission of the vehicle. Particularly, the radar signal processor is developed using two DSP boards in parallel for the various radar signal processing algorithm. The key algorithms include LFM chirp waveform-based pulse compression, MTI clutter filter, MTD processor, adaptive CFAR, and clutter map. Especially airborne moving clutter Doppler spectrum compensation algorithm such as TACCAR is implemented for the multi-mode airborne radar system. The test results shows the good Doppler spectral separation for the clutter and the moving target in the flight test environment using helicopter.

  • PDF

Investigation of detection wavelength of Quantum Well Infrared-Photodetector

  • Hwang, S.H.;Lim, J.G.;Song, J.D.;Shin, J.C.;Heo, D.C.;Choi, W.J.
    • Applied Science and Convergence Technology
    • /
    • v.24 no.6
    • /
    • pp.257-261
    • /
    • 2015
  • We report on GaAs/AlGaAs quantum well infrared photodetectors (QWIPs) that can cover the spectral range of $3.6-25{\mu}m$. One advantage of the GaAs QWIPs is the wavelength tenability as a function of their structural parameters. We have performed a systematic calculation on the detection wavelength of a typical $GaAs/Al_xGa_{1-x}As$ multi-quantum-well photodetector, with the aluminum mole fraction (x) of $Al_xGa_{1-x}As$ barrier in the range of 0.15-0.43 and the quantum-well width range from 30 to 60 $60{\AA}$. Design and fabrication of a QWIP based on $GaAs/Al_{0.23}Ga_{0.77}As$ structure with $37{\AA}$-thick well width has been carried out. The calculated operation wavelength of the QWIP is in a good agreement with the experimental data taken by photo response and activation energy calculation from thermal quenching of integrated photoluminescence.

Impact Monitoring in Composite Beam Using Stabilization Controlled FBG Sensor System (안정화된 FBG 센서를 이용한 복합적층보에서의 충격위치검출)

  • Bang Hyung-Joon;Park Sang-Oh;Hong Chang-Sun;Kim Chun-Gon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.103-106
    • /
    • 2004
  • Impact location monitoring is one of the major concerns of the smart health monitoring. For this application, multipoint ultrasonic sensors are to be employed. In this study, a multiplexed FBG sensor system with wide dynamic range was proposed and stabilization controlling system was also developed for the maintenance of maximum sensitivity of sensors. For the intensity demodulation system of FBG sensors, Fabry-Perot tunable filter(FP-TF) with 23.8nm FSR(free spectral range) was used, which behaves as two separate filters between $1530 \~ 1560$ nm range. Two FBG sensors were attached on the bottom side of the graphite/epoxy composite beam specimen, and low velocity impact tests were performed to detect the one-dimensional impact locations. Impact locations were calculated by the arrival time differences of the impact longitudinal waves acquired by the two FBGs. As a result, multiplexed in-line FBG sensors could detect the moment of impact precisely and found the impact locations with the average error of 1.32mm.

  • PDF

Robust CFO Acquisition in PN-Padded OFDM Systems

  • Liu, Guanghui;Zeng, Liaoyuan;Li, Hongliang;Xu, Linfeng;Wang, Zhengning
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.706-709
    • /
    • 2013
  • As an alternative to the traditional pilot-aided orthogonal frequency division multiplexing (OFDM), the time-domain pseudonoise (PN)-padded OFDM provides a higher spectral efficiency. However, the carrier frequency offset (CFO) attenuates peaks of the conventional PN correlation output, which limits the CFO estimation range of the OFDM synchronizer. An improved correlation is proposed in this letter to remove the CFO-induced amplitude attenuation of correlation peaks. For a synchronizer adopting the designed correlator, a larger range of CFO acquisition is obtained through using wider correlation windows with a smaller interval between them. The proposed method of CFO acquisition is verified in a digital terrestrial multimedia broadcast receiver, in which the synchronizer is able to acquire CFOs up to ${\pm}320$ kHz in the DVB-T F1 channel. Furthermore, the acquisition range can be expanded in more favorable channels.

Application Utility Analysis of Series-cascaded Ring Resonators Based on SOI Slot Optical Waveguides in Integrated Optical Biochemical Sensor (SOI 슬롯 광도파로 기반 캐스케이드 링 공진기 바이오·케미컬 집적광학 센서의 효용성 해석)

  • Jang, Jaesik;Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.353-359
    • /
    • 2022
  • This study investigated via computational analysis the application utility of series-cascaded ring resonators based on silicon-on-insulator (SOI) slot optical waveguides in integrated optical biochemical sensors. The radii of the two rings in the series-cascaded ring resonators were 59.4 ㎛ and 77.6 ㎛ respectively, and the coupling distance was 0.5 ㎛. The series-cascaded ring resonators were computationally analyzed using FIMMProp and PICWave numerical software. The free spectral range (FSR), full width at half maximum (FWHM), sensitivity, and quality-factor (Q-factor) of the series-cascaded ring resonators were 12.2 nm, 0.134 nm, 4100 nm/RIU, and 11580, respectively, and the measurement range was calculated to be slightly smaller than 3×10-3 RIU. Although the measurement range was smaller than that of the single ring resonator, upon considering other characteristic parameters, the series-cascaded ring resonators are found to be more effective as integrated sensors than single ring resonators.

Evaluation of Depth Measurement Method Based on Spectral Characteristics Using Hyperspectrometer (초분광 스펙트로미터를 활용한 분광특성 기반의 수심 측정 기법 적용성 검토)

  • You, Hojun;Kim, Dongsu;Shin, Hyoungsub
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.103-119
    • /
    • 2020
  • Recently, the rapid redeposition and erosion of rivers artificially created by climate change and the Four Rivers Restoration Project is questionable. According to the revised law in Korea, the river management agency will periodically carry out bed changes surveys. However, there are technical limitations in contrast to the trend of increasing spatial coverage, density and narrowing of intervals. National organizations are interest in developing innovative bed changessurvey techniquesfor efficiency. Core of bathymetry survey is to measure the depth of rivers under a variety of river conditions, but that is relatively more risky, time-consuming and expensive compared to conventional ground surveys. To overcome the limitations of traditional technology, echo sounder, which has been mainly used for ocean depth surveying, has been applied to rivers. However, due to various technical limitations, it is still difficult to periodically investigate a wide range of areas. Therefore, technique using the remote sensing has been spotlighted as an alternative, especially showing the possibility of depth measurement using spectral characteristics. In this study, we develop and examine a technique that can measure depth of water using reflectance from spectral characteristics. As a result of applying the technique proposed in thisstudy, it was confirmed that the measured depth and the correlation and error corresponding to 0.986 and 0.053 m were measured in the depth range within 0.95 m. In the future, this study could be applied to the measurement of spatial depth if it is applied to the hyperspectral sensor mounted on the drone.

Antioxidant Activities of Stachys sieboldii MIQ. Stalks (초석잠 [Stachys sieboldii MIQ.] 줄기의 항산화 활성)

  • 백홍석;나영수;류병호;송승구
    • KSBB Journal
    • /
    • v.18 no.4
    • /
    • pp.266-271
    • /
    • 2003
  • This study was worked out to investigate the compounds of antioxidant constituents extracted from Stachys Sieboldii MiQ. and their effects on antioxidant activity by DPPH method, ferric thiocyanate method, and nitrite scavenging ability. Solvents such as methanol, hexane, chloroform, ethyl acetate, butanol, and water were used for this purpose. Total concentrations of polyphenols and flavonoids were measured in the methanol fraction. The ethyl acetate fraction showed the strongest activity by DPPH method, ferric thiocyanate method, and nitrite scavenging ability. The ethyl acetate extract was fractionated on a silica gel column using elution solvent (chloroform: methanol: water = 70 : 30 : 5 lower phase) at a flow rate of 1.0 mL/min. UV-VIS spectral data of each fraction showed adsorption maxima in the range of 284~330 nm. Among fractions, the fraction 1 that has λ$\_$max/ (nm) of 284 nm showed the strongest activity by DPPH method. The UV-VIS spectral data of phenolic compounds were known to lie in the range of 210~290 nm and 300~550 nm. Therefore, the results of our study suggested that Stachys sieboldii MIQ. contains phenolic compounds showing natural antioxidant activity.

Spectral Analysis Method to Eliminate Spurious in FMICW HRR Millimeter-Wave Seeker (주파수 변조 단속 지속파를 이용하는 고해상도 밀리미터파 탐색기의 스퓨리어스 제거를 위한 스펙트럼 분석 기법)

  • Yang, Hee-Seong;Chun, Joo-Hwan;Song, Sung-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.85-95
    • /
    • 2012
  • In this thesis, we develop a spectral analysis scheme to eliminate the spurious peaks generated in HRR Millimeterwave Seeker based on FMICW system. In contrast to FMCW system, FMICW system generates spurious peaks in the spectrum of its IF signal, caused by the periodic discontinuity of the signal. These peaks make the accuracy of the system depend on the previously estimated range if a band pass filter is utilized to eliminate them and noise floor go to high level if random interrupted sequence is utilized and in case of using staggering process, we must transmit several waveforms to obtain overlapped information. Using the spectral analysis one of the schemes such as IAA(Iterative Adaptive Approach) and SPICE(SemiParametric Iterative Covariance-based Estimation method) which were introduced recently, the spurious peaks can be eliminated effectively. In order to utilize IAA and SPICE, since we must distinguish between reliable data and unreliable data and only use reliable data, STFT(Short Time Fourier Transform) is applied to the distinguishment process.

Status Report of the NISS and SPHEREx Missions

  • Jeong, Woong-Seob;Park, Sung-Joon;Moon, Bongkon;Lee, Dae-Hee;Park, Won-Kee;Lee, Duk-Hang;Ko, Kyeongyeon;Pyo, Jeonghyun;Kim, Il-Joong;Park, Youngsik;Nam, Ukwon;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.58.2-58.2
    • /
    • 2016
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is the near-infrared instrument optimized to the first small satellite of NEXTSat series. The capability of both imaging and low spectral resolution spectroscopy with the Field of View of $2{\times}2deg.$ in the near-infrared range from 0.9 to $3.8{\mu}m$ is a unique function of the NISS. The major scientific mission is to study the cosmic star formation history in local and distant universe. The Flight Model of the NISS is being developed and tested. After an integration into NEXTSat-1, it will be tested under the space environment. The NISS will be launched in 2017 and it will be operated during 2 years. As an extension of the NISS, SPEHREx (Spectro-Photometer for the History of the Universe Epoch of Reionization, and Ices Explorer) is the NASA SMEX (SMall EXploration) mission proposed together with KASI (PI Institute: Caltech). It will perform an all-sky near-infrared spectral survey to probe the origin of our Universe; explore the origin and evolution of galaxies, and explore whether planets around other stars could harbor life. The SPHEREx is designed to have wider FoV of $3.5{\times}7deg.$ as well as wider spectral range from 0.7 to $4.8{\mu}m$. After passing the first selection process, SPHEREx is under the Phase-A study. The final selection will be made in the end of 2016. Here, we report the current status of the NISS and SPHEREx missions.

  • PDF