• Title/Summary/Keyword: Spectral Estimation

Search Result 534, Processing Time 0.043 seconds

Acoustic Estimation of Phase Velocity of Closed-Cell Kelvin Structure based on Spectral Phase Analysis

  • Kim, Nohyu
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.339-345
    • /
    • 2022
  • In this paper, the effect of porosity on the acoustic phase velocity of the 3D printed Kelvin closed-cell structure was investigated using the spectral phase analysis. Since Kelvin cells bring about the large amount of scattering, acoustic pulses in ultrasonic measurements undergoes a distortion of waveforms due to the dispersion effect. In order to take account on the dispersion, mathematical expressions for calculating the phase velocity of longitudinal waves propagating normal to the plane of the Kelvin structure are suggested by introducing a complex wave number based on Fourier transform. 3D Kelvin structure composed of identical unit-cells, a polyhedron of 14 faces with 6 quadrilateral and 8 hexagonal faces, was developed and fabricated by 3D CAD and 3D printer to represent the micro-structure of porous materials such as aluminum foam and cancellous bone. Total nine samples of 3D Kelvin structure with different porosity were made by changing the thickness of polyhedron. Ultrasonic pulse of 1MHz center frequency was applied to the Kelvin structures for the measurement of the phase velocity of ultrasound using the TOF(time-of-flight) and the phase spectral method. From the experimental results, it was found that the acoustic phase velocity decreased linearly with the porosity.

Across-wind dynamic loads on L-shaped tall buildings

  • Li, Yi;Li, Qiu-Sheng
    • Wind and Structures
    • /
    • v.23 no.5
    • /
    • pp.385-403
    • /
    • 2016
  • The across-wind dynamic loads on L-shaped tall buildings with various geometric dimensions were investigated through a series of wind tunnel testing. The lift coefficients, power spectral densities and vertical correlation coefficients of the across-wind loads were analyzed and discussed in details. Taking the side ratio and terrain category as key variables, empirical formulas for estimating the across-wind dynamic loads on L-shaped tall buildings were proposed on the basis of the wind tunnel testing results. Comparisons between the predictions by the empirical formulas and the wind tunnel test results were made to verify the accuracy and applicability of the proposed formulas. Moreover, a simplified procedure to evaluate the across-wind dynamic loads on L-shaped tall buildings was derived from the proposed formulas. This study aims to provide a simple and reliable way for the estimation of across-wind dynamic loads on L-shaped tall buildings.

Estimation of Visual Evoked Potentials Using Time-Frequency Analysis (시-주파수 분석법을 이용한 시각자극 유발전위에 관한 연구)

  • 홍석균;성홍모;윤영로;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.259-267
    • /
    • 2001
  • The visual evoked potentials(VEPs) is used to assist in the diagnosis of specific disorders associated with involvement of the sensory visual pathways. The P100 latency is an important parameter which is diagnosis of optic nerve disorders. There are characteristics of latency delay, wave distortion, amplitude deduction in abnormal subjects. It is difficult to diagnose in the case of producing peak at the P100 latency. In this paper, difference of pattern between normal VEPs and abnormal VEPs using the Choi-Williams distribution method is studied. We observed the relationship about time and spectrum. The result shown that normal VEPs had maximum spectral value at 20Hz~26.7Hz and abnormal VEPs had maximum spectral value at 16.7Hz~20Hz. Also normal VEPs spectrum is higher than abnormal VEPs spectrum.

  • PDF

Convergence Properties of a Spectral Density Estimator

  • Gyeong Hye Shin;Hae Kyung Kim
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.3
    • /
    • pp.271-282
    • /
    • 1996
  • this paper deal with the estimation of the power spectral density function of time series. A kernel estimator which is based on local average is defined and the rates of convergence of the pointwise, $$L_2$-norm; and; $L{\infty}$-norm associated with the estimator are investigated by restricting as to kernels with suitable assumptions. Under appropriate regularity conditions, it is shown that the optimal rate of convergence for 0$N^{-r}$ both in the pointwiseand $$L_2$-norm, while; $N^{r-1}(logN)^{-r}$is the optimal rate in the $L{\infty}-norm$. Some examples are given to illustrate the application of main results.

  • PDF

Ocean Scanning Multi-spectral Imager (OSMI) Pre-Launch Radiometric Performance Analysis

  • Cho, Young-Min
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.390-395
    • /
    • 1999
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the Korean Multi-purpose SATellite (KOMPSAT) to perform worldwide ocean color monitoring for the study of biological oceanography KOMPSAT will be launched in the middle of November this year. The radiometric performance of OSMI is analyzed for various gain settings in the viewpoint of the instrument developer for OSMI calibration and application based on its ground performance measurement data for 8 primary spectral bands of OSMI. The radiometric response linearity and dynamic range are analyzed for the image radiometric calibration and the estimation of OSMI image quality for the ocean remote sensing area. The dynamic range is compared with the nominal input radiance for the ocean and the land. The noise equivalent radiance (NER) corresponding to the instrument radiometric noise is compared with the radiometric resolution of signal digitization (1-count equivalent radiance). The best gain setting of OSMI for ocean monitoring is recommended. This analysis is considered to be useful for the OSMI mission and operation planning, the OSMI image data calibration, and users' understanding about OSMI image quality.

  • PDF

The Comparison of Speaker Adaptation Methods (화자 적응 방법들의 비교)

  • 황영수
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.61-66
    • /
    • 1999
  • In this paper, we proposed various speaker adaptation methods and studied the performance of these methods. Methods which were studied in this paper are MAPE(Maximum A Posteriori Probability Estimation), Linear Spectral Estimating, Multi-Layer Perceptron and ARTMAP. In order to evaluate the performance of these methods, we used Korean isolated digits as the experimental data, the hybrid speaker adaptation method, which unified MAPE, linear spectral estimating and output probability of SCHMM, showed the better recognition result than those which performed other methods. And the method using ARTMAP showed the similar result to above hybrid method.

  • PDF

A Study on the Power Spectral Analysis of Background EEG with Pisarenko Harmonic Decomposition (Pisarenko Harmonic Decomposition에 의한 배경 뇌파 파워 스펙트럼 분석에 관한 연구)

  • Jung, Myung-Jin;Hwang, Soo-Young;Choi, Kap-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1271-1275
    • /
    • 1987
  • With the stochastic process which consists of the harmonic sinusoid and the white nosie, the power spectrum of background EEG is estimated by the Pisarenko Harmonic Decomposition. The estimating results are examined and compared with the results from the maximum entropy spectral estimation, and the optimal order of this model can be determined from the eigen value's fluctuation of autocorrelation of background EEG. From the comparing results, this paper ensures that this method is possible to analyze the power spectrum of background EEG.

  • PDF

Estimation of Attenuation Coefficient based on Ultrasonic Image for quantification of the Liver Diseases (간 병변의 정량화를 위한 초음파 영상 신호의 감쇄상수 추정)

  • 우광방;신동호;이성모;신영민;이노성;오성권
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.1
    • /
    • pp.49-55
    • /
    • 1988
  • To provide a quantitative parameter of evaluating diagnosis of the liver diseases accurately, the ultrasonic attenuation coefficient was estimated from liver phantoms, 15 normal human livers and 30 liver disease patients. Two kind of phantoms(No.1: 1552m/s, No.2: 1562m/s) which have velocity (1560m/s) similar to that in human liver were constructed and their ultrasonic attenuation coefficients were determined. In this paper the spectral-shift approach and spectral-difference approach were used for estimating ultrasonic attenuation coefficient, \ulcornerdB/Cm.MHz). These two approaches were utilized to esitmate for 15 normal humans without any liver disease and 30 liver disease patients. The results indicate that the two types of phantoms produce the value of near the suggested value of 0.5 and the attenuation coefficients of hepatoma, normal liver, corrhosis, fatty liver and hepatitis show decreasing value in order named, suggesting that the present study can be of clinical value incorrelating the estimated attenuation coefficidents with the liver diseases.

  • PDF

IMAGE CLASSIFICATION OF HIGH RESOLTION MULTISPECTRAL IMAGERY VIA PANSHARPENING

  • Lee, Sang-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.18-21
    • /
    • 2008
  • Lee (2008) proposed the pansharpening method to reconstruct at the higher resolution the multispectral images which agree with the spectral values observed from the sensor of the lower resolution values. It outperformed over several current techniques for the statistical analysis with quantitative measures, and generated the imagery of good quality for visual interpretation. However, if a small object stretches over two adjacent pixels with different spectral characteristics at the lower resolution, the pixels of the object at the higher resolution may have different multispectral values according to their location even though they have a same intensity in the panchromatic image of higher resolution. To correct this problem, this study employed an iterative technique similar to the image restoration scheme of Point-Jacobian iterative MAP estimation. The effect of pansharpening on image segmentation/classification was assessed for various techniques. The method was applied to the IKONOS image acquired over the area around Anyang City of Korea.

  • PDF

A Study on the Development of the EMf System Using Personal Computer (개인용 컴퓨터를 이용한 근전도(EMG) 시스템 개발에 관한 연구)

  • 조승진;김민수
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.243-248
    • /
    • 1990
  • EMG (eleltromyographic) signals are generated by contracting muscle and detected in and out side of muscle in the form of random signals. In the measurement of muscle fatigue, the mean frequency of EMG signals using spectrum analysis is an important parameter in diagonosis of muscle disease and in sports medicine fields. In this study, the degree of spectral transfer to lower frequency caused by accumulation of Latic acid inside the muscle is estimated. The new spectral analysis method using 2"d order hAaximum Entropy Method was applied to estimate the mean frequency and we confirmed that this new method yields fast and reliable estimation.tion.

  • PDF