• Title/Summary/Keyword: Specimen

Search Result 10,812, Processing Time 0.038 seconds

THE PREVENTIVE EFFECT OF COMMERCIALLY AVAILABLE ANTICARIOGENIC PRODUCTS ON ENAMEL EROSION INDUCED BY CARBONATED BEVERAGE IN VITRO (탄산음료 유발 법랑질 침식에 대한 항우식 제품의 예방 효과)

  • Song, Ju-Hyun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • The aim of this study was to evaluate the preventive effect of commercially available anticariogenic products, specifically, the tooth cream containing Casein phosphopeptide-amorphous calcium phosphate(CPP-ACP), fluoride varnish and low-level fluoride mouthrinse on enamel erosion induced by carbonated beverage in a short period of time. Enamel specimens were treated as follows and were then kept in artificial saliva for 24 hours followed by further processing by alternately soaking them in Cola beverage and in distilled water for 1 minute each five times. Group 1: control group (no treatment) Group 2: tooth cream with CPP-ACP Group 3: fluoride varnish (1,000 ppm F) Group 4: low-level fluoride mouthrinse (227 ppm F) Group 5: fluoride varnish + tooth cream with CPP-ACP Group 6: low-level fluoride mouthrinse + tooth cream with CPP-ACP Microhardness and erosion depth were measured and the mineral loss of each specimen was evaluated by measuring the volumetric fluorescence change(${\Delta}Q$) against the stable fluorescent grid using quantitative light-induced fluorescence(QLF). The experiment lasted for 6 days repeated each day. The results were as follows: 1. The microhardness was increased as follows: Group $1{\leq}2{\leq}4$<6<$3{\fallingdotseq}5$. 2. The mean erosion depth was increased as follows: Group $5{\fallingdotseq}3$<6<$4{\fallingdotseq}2{\fallingdotseq}1$. 3. The ${\Delta}Q$ was increased as follows: Group $1{\fallingdotseq}2{\leq}4{\leq}6{\leq}3{\fallingdotseq}5$. The decrement of ${\Delta}Q$ was similar between group 1 and 2, group 4 and 6 and group 3 and 5. 4. The ${\Delta}Q$ showed positive correlation with microhardness (r=0.96, p<0.05), while it was negatively correlated to erosion depth (r=-0.96, p<0.05).

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

A Clinical Study on Fiberoptic Bronchoscopy (화이버 기관지경 검사의 임상적 고찰)

  • 이상기;홍영호;권평중;김중환
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.3.2-3
    • /
    • 1981
  • This paper was attemped to analize 55 cases of fiberoptic bronchoscopy during period of 3 years from Feb. 1978 till Feb. 1981 in Chung Ang University hospital. The results were as follow; 1) In age distribution; Most common age group was 5th decade (15 cases, 27.2%) and the other age groups showed relatively even distribution. 2) The ratio of male to female was 3 to 1. 3) The chief complaints were presented in following order; cough (52%), hemoptysis(25%), dyspnea(23.6%), chest pain(18%), chest disomfort(9%). 4) Direct smear of bronchoscopic aspiration material; Not found 33 cases (60%) were most common finding. In the founded bacteria Gram positive cocci 2 cases (3.6%), Gram negative cocci 2 cases (3.6%), Gram positive bacilli 1 cases (1.8%), Gram negativebacilli 2 cases (3.6%), mixed form 15 cases(27.2%) were presented. 5) Bacterial culture of bronchoscopic aspiration material; No growth 28 cases (50.9%) were most common finding. In the bacterial growth, alpha hemolytic streptococci 10 cases (18.2%), Neisseria group 7cases(12.7%), Klebsiella 2 cases (3.6%), Pseudomonas 2 cases (3.6%), mixed culture 6 cases (10.9%) were presented, 6) The diagnosis of bronchoscopic appearance, laboratory exam., and pathologic exam. of biopsed specimen were 21 cases (38.1%) primary carcinoma of bronchus, 8 cases (14.5%) pulmonary tuberculosis, 7 cases (12.7%) bronchitis in orders.

  • PDF

Floral Studies on Korean Wood-rotting Fungi (II) -on the flora of the Aphyllophorales(Basidiomycotina)- (한국산(韓國産) 목재부후균류(木材腐朽菌類)의 분포상(分布相)에 대한 연구(硏究) (II) -담자균류(擔子菌類) 민주름버섯목(目)의 분포(分布)에 대하여-)

  • Jung, Hack-Sung
    • The Korean Journal of Mycology
    • /
    • v.22 no.1
    • /
    • pp.62-99
    • /
    • 1994
  • The fungal flora of Korean wood-rotting fungi were studied for two years from March of 1990 to February of 1992. Fresh fungi were collected from national parks, local areas, and islands throughout the country. Fleshy fungi of the Aphyllophorales were identified through specimen examination and literature studies. Total 217 species and 1 variety were counted, among which Aleurodiscus cerussatus, Botryobasidium obtusisporum, Ceraceomyces cystidiatus, Erythricium hypnophilum, Grandinia crustosa, Grandinia spathulata, Hyphoderma praetermissum, Hyphoderma roseocremeum, Hypochnicium bombycinum, Hypochnicium detriticum, Hypochnicium lundellii, Laeticorticium roseum, Mycoacia fuscoatra, Peniophora incarnata, Phanerochaete avellanea, Phanerochaete filamentosa, Phanerochaete martelliana, Phlebia lilascens, and Trechispora vaga under the Corticiaceae, Chondrostereum purpureum and Cystostereum subabruptum under the Stereaceae, Tomentella pilosa under the Thelephoraceae, Asterostroma laxum, Hymenochaete cruenta, Hymenochaete fuliginosa, Hymenochaete tabacina, Inonotus radiatus, and Phellinus pomaceus under the Hymenochaetaceae, Antrodia crassa, Antrodia serialis, Ceriporia reticulata, Oligoporus balsameus, Oligoporus guttulatus, Oxyporus cuneatus, Rigidoporus microporus, and Trichaptum laricinum under the Polyporaceae, total 36 species were confirmed as unrecorded species to Korea and are registered here with Korean names and English descriptions.

  • PDF

Synthesis of Ceramic Support for Immobilization of Microorganisms Using Fly Ash (석탄회를 이용한 미생물 고정화 세라믹 담체 제조)

  • Shin, Dae-Yong;Han, Sang-Mok;Choi, Shin-Geon
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.857-862
    • /
    • 2002
  • Porous ceramic supports with immobilized microorganisms for the water purifier were synthesized by firing green compacts of mixed powder comprising of fly ash, bentonite and an additive of yeast powder at 800∼1,000$^{\circ}C$ for 1h and the pore and mechanical properties of specimens were investigated. The compressive strength was increased in FB (Fly Ash + Bentonite) specimens while pore properties was decreased with increasing the bentonite content and sintering temperature. The compressive strength, bulk density, apparent density, porosity, mean pore size, pore volume and specific surface area of FB specimens at 800∼1,000$^{\circ}C$ were 89.6∼128.9 kgf/$cm^2$, 1.25∼1.43, 1.61∼1.78, 27.2∼62.2%, 7.9∼25.6 ${\mu}m$, 8.9∼$22.2{\times}10^{-5}\;cm^3/g$ and 35.2∼134.3 $m^2/g$, respectively. The pore properties of FBY (FB+yeast powder) specimens were superior to that of FB specimens, however compressive strength was decreased with increasing yeast powder content. The overall properties of 9F1B1Y (9F1B+10% of yeast powder) specimens at 900$^{\circ}C$ for 1 h were 98.7 kgf/$cm^2$, 1.20, 1.67, 68.1%, 48.9 ${\mu}m$, $29.5{\times}10^{-5}\;cm^3/g$ and 152.2 $m^2/g$, respectively. In this study, it was revealed that 9F1B1Y specimen demonstrated better S. saprophyticus adherence properties n their surface pores. Consequently, the microorganisms immobilized on porous ceramic supports showed better water purifying performance with many pores and adequate strength.

Lesion Localization in Patients with Hyperparathyroidism Using Double-phase Tc-99m MIBI Parathyroid Scintigraphy (부갑상선기능항진증 환자에서 Tc-99m MIBI 부갑상선 신티그라피를 이용한 병소 국소화)

  • Shin, Jung-Woo;Ryu, Jin-Sook;Kim, Jae-Seung;Moon, Dae-Hyuk;Hong, Seung-Mo;Gong, Gyung-Yub;Hong, Suk-Joon;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.120-130
    • /
    • 1999
  • Purpose: This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyper-parathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. Materials and Methods: The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyper-parathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. Results: In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of early and delayed images were 46.7% (7/15), 76.9% (10/13), 70% (7/10) and 66.7% (10/15), 92.3% (12/13), 90.9% (10/11), respectively. SPECT image detected an additional small hyperplasia.. The sensitivity, specificity, and positive predictive value of combined interpretation of early and delayed images with SPECT were 73.3% (11/15), 100% (13/13), 100% (11/11). The sensitivity was 100% (6/6) for adenoma, whereas that was 55.5% (5/9) for hyperplasia. Both adenomas and hyperplasias showed significantly increased oxyphil cell contents compared with normal parathyroid glands (p<0.0001), but the oxyphil cell content and weight were not significantly different between adenomas and hyperplasias. Conclusion: Double-phase Tc-99m MIBI parathyroid scintigraphy with SPECT is useful for lesion localization in patients with hyperparathyroidism. Although both adenoma and hyperplasia have increased oxyphil cell content, the sensitivity is high in adenoma, but low in hyperplasia.

  • PDF

Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins (CAD/CAM 의치상 레진과 열중합 의치상 레진의 두께에 따른 굴곡 강도 비교)

  • Lee, Dong-Hyung;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.183-195
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the flexural strength of CAD/CAM denture base resins with conventional denture base resins based on their thicknesses. Materials and Methods: For the conventional denture base resins, Lucitone 199® (C-LC) was used. DIOnavi - Denture (P-DO) and DENTCA Denture Base II (P-DC) were taken for the 3D printing denture base resins. For the prepolymerized PMMA resins, Vipi Block Gum (M-VP) and M-IVoBase® CAD (M-IV) were used. The final dimensions of the specimens were 65.0 mm x 12.7 mm x 1.6 mm / 2.0 mm / 2.5 mm. The 3-point bend test was implemented to measure the flexural strength and flexural modulus. Microscopic evaluation of surface of fractured specimen was conducted by using a scanning electron microscope (SEM). After testing the normality of the data, one-way ANOVA was adopted to evaluate the differences among sample groups with a significance level of P = 0.05. The Tukey HSD test was performed for post hoc analysis. Results: Under the same thicknesses, there are significant differences in flexural strength between CAD/CAM denture base resins and conventional denture base resins except for P-DO and C-LC. M-VP showed higher flexural strength than conventional denture base resins, P-DC and M-IV displayed lower flexural strength than conventional denture base resins. Flexural modulus was highest in M-VP, followed by C-LC, P-DO, P-DC, M-IV, significant differences were found between all materials. In the comparison of flexural strength according to thickness, flexural strength of 2.5 mm was significantly higher than that of 1.6 mm in C-LC. Flexural strength of 2.5 mm and 2.0 mm was significantly higher than that of 1.6 mm in P-DC and M-VP. In M-IV, as the thickness increases, significant increase in flexural strength appeared. SEM analysis illustrates different fracture surfaces of the specimens. Conclusion: The flexural strength of different CAD/CAM denture base resins used in this study varied according to the composition and properties of each material. The flexural strength of CAD/CAM denture base resins was higher than the standard suggested by ISO 20795-1:2013 at a thickness of 1.6 mm or more though the thickness decreased. However, for clinical use of dentures with lower thickness, further researches should be done regarding other properties at lower thickness of denture base resins.

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.

IS AN OXYGEN INHIBITION LAYER ESSENTIAL FOR THE INTERFACIAL BONDING BETWEEN RESIN COMPOSITE LAYERS? (Layering시 복합레진 층간의 계면 결합에서 oxygen inhibition layer가 필수적인가?)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.405-412
    • /
    • 2008
  • This study was aimed to investigate whether an oxygen inhibition layer (OIL) is essential for the interfacial bonding between resin composite layers or not. A composite (Z-250, 3M ESPE) was filled in two layers using two aluminum plate molds with a hole of 3.7 mm diameter. The surface of first layer of cured composite was prepared by one of five methods as followings, thereafter second layer of composite was filled and cured: Group 1 - OIL is allowed to remain on the surface of cured composite; Group 2 - OIL was removed by rubbing with acetone-soaked cotton; Group 3 - formation of the OIL was inhibited using a Mylar strip; Group 4 - OIL was covered with glycerin and light-cured; Group 5 (control) - composite was bulk-filled in a layer. The interfacial shear bond strength between two layers was tested and the fracture modes were observed. To investigate the propagation of polymerization reaction from active area having a photo-initiator to inactive area without the initiator, a flowable composite (Aelite Flow) or an adhesive resin (Adhesive of ScotchBond Multipurpose) was placed over an experimental composite (Exp_Com) which does not include a photoinitiator and light-cured. After sectioning the specimen, the cured thickness of the Exp_Com was measured. The bond strength of group 2, 3 and 4 did not show statistically significant difference with group 1. Groups 3 and 4 were not statistically significant different with control group 5. The cured thicknesses of Exp_Com under the flowable resin and adhesive resin were 20.95 (0.90) urn and 42.13 (2.09), respectively.