• 제목/요약/키워드: Specific power

검색결과 2,669건 처리시간 0.031초

Deployment of Radioactive Waste Disposal Facility with the Introduction of Nuclear Power Plants (NPP) in Kenya

  • Shadrack, A.;Kim, C.L.
    • Journal of Nuclear Fuel Cycle and Waste Technology
    • /
    • 제1권1호
    • /
    • pp.37-47
    • /
    • 2013
  • This paper describes basic plans for the development of a radioactive waste disposal facility with the introduction of Nuclear Power Plants (NPPs) for Kenya. The specific objective of this study was to estimate the total projected waste volumes of low- and intermediate-level radioactive waste (LILW) expected to be generated from the Kenyan nuclear power programme. The facility is expected to accommodate LILW to be generated from operation and decommissioning of nuclear power plants for a period of 50 years. An on-site storage capacity of 700 $m^3$ at nuclear power plant sites and a final disposal repository facility of more than 7,000 $m^3$ capacity were derived by considering Korean nuclear power programme radioactive waste generation data, including Kori, Hanbit, and APR 1400 nuclear reactor data. The repository program is best suited to be introduced roughly 10 years after reactor operation. This study is important as an initial implementation of a national LILW disposal program for Kenya and other newcomer countries interested in nuclear power technology.

Development of a Novel Tracking System for Photovoltaic Efficiency in Low Level Radiation

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.405-411
    • /
    • 2010
  • This paper proposes a novel tracking algorithm considering radiation to improve the power of a photovoltaic (PV) tracking system. The sensor method used in a conventional PV plant is unable to track the sun's exact position when the intensity of solar radiation is low. It also has the problem of malfunctions in the tracking system due to rapid changes in the climate. The program method generates power loss due to unnecessary operation of the tracking system because it is not adapted to various weather conditions. This tracking system does not increase the power above that of a power of tracking system fixed at a specific position due to these problems. To reduce the power loss, this paper proposes a novel control algorithm for a tracking system and proves the validity of the proposed control algorithm through a comparison with the conventional PV tracking method.

전력계통설비의 정지관리 체계화 방안에 대한 연구 (A Study on the Outage Management Standards for Power System)

  • 허정용;김철환;김재철;이건웅;이성진;이창규;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.107-109
    • /
    • 2004
  • It is very important to operate a power system safely. An fault may causes the cascading outages in power system. Use of systematic, precise definitions related to the outages is essential for meaningful exchange of data. Moreover, it is necessary that specific instructions for reporting outages is developed. This paper presents the outage management for a power system. The outage managements of the many utilities are researched, which include the definition, classification, index and report of outage. Finally, the outage management standard is proposed, and the necessity and structure of KERC(Korean Electric Reliability Council) are presented

  • PDF

카오스 퍼지 제어기를 이용한 전력소요량의 단기예측에 관한 연구 (A Study on Short-Term Prediction of Supplied Electrical Power using Chaos Fuzzy Controller)

  • 추연규;정대균
    • 한국항해학회지
    • /
    • 제24권3호
    • /
    • pp.147-155
    • /
    • 2000
  • In this paper, we propose the Chaos Fuzzy controller to analyze the chaotic character of time series obtained from the specific plant and to predict the short-term for power consumption of the plant using the Fuzzy controller. We compared the predicted data with the active ones and checked the error generated by them after we time series of supplied power to the proposed controller. As a result of the simulation, we obtained a admirable consequence that the proposed controller can be advanced through various and accurate data acquisition, and continuous analysis of the resident and industrial environment.

  • PDF

Analysis of Multi Level Current Source GTO Inverter for Induction Motor Drives

  • Arase, Takayuki;Matususe, Kouki
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.535-540
    • /
    • 1998
  • This paper discusses a triple stage current source GTO inverter system for high power motor drives. The energy rebound circuit of the triple stage inverter not only controls the spike voltage of the GTO inverter but also facilitates PWM control of the thyristor rectifier operated at unity fundamental input power factor. Based on Pspice simulation and experiments, the principles and PWM pulse pattern for removing specific lower harmonics in the inverter's output current are discussed in detail.

  • PDF

리티움-이온 배터리를 이용한 풍력발전의 출력안정화 시스템 개발 (Development of the wind generation output stabilization with Lithium-ion battery)

  • 오승진;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.178-179
    • /
    • 2010
  • This paper presents a simulation model and analysis of grid-tied wind turbine generator with batteries using the PSCAD/EMTDC software. The modeled system is consist of two inverters and one bidirectional DC/DC converter. These inverter are to capture the maximum active power under varying wind conditions and to keep the DC-Link voltage magnitude at a specific level. And the bidirectional DC/DC converter makes battery charging or discharging depend on power gap between wind turbine output and local load. Aerodynamic models are applied for a wind turbine blade simulator.

  • PDF

초전도케이블의 실계통 적용가능 개소 도출 및 적용효과 검토 (Specific Case selection and basic power system analysis for applying HTSC to KEPCO system)

  • 이승렬;윤재영;김종율
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.167-170
    • /
    • 2003
  • This study alms at analyzing a power system, in case of installing HTS cable in the system. First of all, we determine the case that HTS cable can be applied to KEPCO systems and analyze the static state of power system. Then we propose a solution of the problem resulting from the analysis.

  • PDF

배터리 에너지 저장장치를 이용한 10kW 풍력발전출력 안정화 시스템 개발 (Battery energy storage system for 10kW wind turbine output stabilization)

  • 오승진;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.36-37
    • /
    • 2010
  • This paper presents a simulation model and results of experiment about analysis of grid-tied wind turbine generator with batteries. The system consists of two inverters and a bidirectional DC/DC converter. These inverters are to capture the maximum active power under varying wind conditions and to keep the DC-link voltage magnitude at a specific level. And the bidirectional DC/DC converter makes battery charging or discharging depend on power gap between wind turbine output and local load.

  • PDF

곤륜의 전침 자극이 뇌파에 미치는 영향 (The Effect of Electroacupuncture at the BL60 (Kollyun) on the EEG)

  • 이태영;이광규;장윤성;육상원;이창현;이상룡
    • Korean Journal of Acupuncture
    • /
    • 제20권2호
    • /
    • pp.31-46
    • /
    • 2003
  • Objectives : The aim of this study was to examine the effects of electroacupuncture(EA) at the BL60 (Kollyun) on normal humans using power spectral analysis. Methods : EEG power spectrum exhibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 channel EEG study was carried out in 10 subjects $(10\;males;\;age=22.4{\pm}0.5$ years). Results : In alpha band, the power values at Fz during the non-acupoint treatment and at Fp2, T5 during the BL60-acupoint treatment significantly were decreased. In beta band, the power values at C3, Po2, O2, Oz during the BL60-acupoint treatment significantly were increased than the before-acupuncture treatment. In theta band, the power values at F7 during the BL60-acupoint treatment significantly was increased. However, the comparison with that before and after the treatment shows no significant differences in all channels.

  • PDF

내관$(PC_6)$의 황련해독탕 약침이 EEG 변화에 미치는 효과 (The Effect of Hwangryunhaedoktang Herbal Acupuncture at the $PC_6$(Naegwan) on the EEG)

  • 김동석;이상룡
    • Korean Journal of Acupuncture
    • /
    • 제21권3호
    • /
    • pp.39-58
    • /
    • 2004
  • Objectives : The aim of this study was to examine the effects of Hwangryunhaedoktang Herbal acupuncture at the PC6(Naegwan) on the EEC of normal human being by using power spectral analysis. Methods : EEC power spectrum exhibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 32 channel EEC study was carried out in 11 subjects (11 males; age=27.8 years). Results : In ${\alpha}(alpha)$ band, the power values at T3, TT1, CP1, T5, Po2, O1, Oz channels(p<0.05) during the PC6-acupoint treatment were increased significantly. In ${\beta}(beta)$ band, the power values at TT1, CP1, T5, P3, Po2, O1, Oz channels(p<0.05) during the PC6-acupoint treatment were increased significantly. In ${\theta}(theta)$ band, the power values at T3, TT1, CP1, Po2, O1, Oz channels(p<0.05) during the PC6-acupoint treatment were increased significantly. In ${\delta}(delta)$ band, the power values at F4, T3, CP1, O1, Oz, O2 channels(p<0.05) during the PC6-acupoint treatment were increased significantly. Conclusions : This results suggest that Hwangryunhaedoktang Herbalacupuncture at the PC6 is significantly in ${\alpha}(alpha)$ band.

  • PDF