• Title/Summary/Keyword: Specific charge

Search Result 582, Processing Time 0.029 seconds

Cultivation and Characteristic Methods for DUS Test New Varieties of Actinidia arguta -Based on the Process of Writing the Manual- (다래(Actinidia arguta) 신품종 심사를 위한 재배 및 특성조사방법 -매뉴얼 작성과정을 기준으로-)

  • Mi-Yun An;Ro-Young Lee;Je-Min Park;Byeong-Hoon Yang;Ki-Yoon Kim
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.4
    • /
    • pp.450-456
    • /
    • 2023
  • The National Forest Seed and Variety Center aims to write a manual for cultivation and characteristic inspection of new seed varieties in Korea, serving dual purposes. The first is the enhancement of the test guidelines, particularly the distinctness, uniformity and stability (DUS) test, for new seed variety, where research and examination are conducted based on the test guidelines. However, if the crop-specific test guidelines are initially reorganized, the details are unclear. Therefore, it seeks to maintain a written record to prevent confusion when the person in charge is changed. The second is to encourage the development of new varieties. By incorporating general characteristics and cultivation techniques in the manual, it seeks to encourage breeders to develop new varieties. Additionally, it serves as an important chronological record of the creation process, thereby helping future manual authors. This article introduces the current status of new plant variety protection and outlines the significance of creating a manual for cultivation and characterization of Actinidia arguta for screening new varieties.

Development of Thermoplastic Carbon Composite Hybrid Bipolar Plate for Vanadium Redox Flow Batteries (VRFB) (바나듐 레독스 흐름전지용 열가소성 탄소 복합재료 하이브리드 분리판 개발)

  • Jun Woo Lim
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.422-428
    • /
    • 2023
  • The electrical contact resistance between the bipolar plate (BP) and the carbon felt electrode (CFE), which are in contact by the stack clamping pressure, has a great impact on the stack efficiency because of the relatively low clamping pressure of the vanadium redox flow battery (VRFB) stack. In this study, a polyethylene (PE) composite-CFE hybrid bipolar plate structure is developed through a local heat welding process to reduce such contact resistance and improve cell performance. The PE matrix of the carbon fiber composite BP is locally melted to create a direct contact structure between the carbon fibers of CFE and the carbon fibers of BP, thereby reducing the electrical contact resistance. Area specific resistance (ASR) and gas permeability are measured to evaluate the performance of the PE composite-CFE hybrid bipolar plate. In addition, an acid aging test is performed to measure stack reliability. Finally, a VFRB unit cell charge/discharge test is performed to compare and analyze the performance of the developed PE composite-CFE hybrid BP and the conventional BP.

Assessing the Suitability of Interruption Intervention Strategies in Nursing Medication Administration: A Delphi Study (간호사의 투약업무흐름 중단 중재전략 적합성 연구: 전문가 델파이 조사를 중심으로)

  • Seung Ju Baek;Seung Gyeong Jang;Sang Hee Hong;Soo Ok Han;Won Lee
    • Quality Improvement in Health Care
    • /
    • v.30 no.1
    • /
    • pp.88-104
    • /
    • 2024
  • Purpose: This study explored the suitability of interventions for medication interruption and intervention preferences. Methods: Two rounds of Delphi surveys were conducted with 18 expert panels comprising staff (or charge) nurses, nursing managers, and Quality Improvement (QI) team nurses working in a tertiary general hospital. For 47 situations involving the location of interruption, medication step, and source of interruption, the suitability of three interventions (no-interruption zone, medication safety vest, and education) was evaluated using a 5-point scale. Results: A total of 51 interventions for each situation were found appropriate by satisfying the degree of convergence and consensus. Patients or caregivers, peer nurses, doctors, telephones, and call bells were sources of interruption and were identified as appropriate for the application of interventions. 'Responding to requests and inquiries' by patients or caregivers showed high overall suitability. The nurses' preferred color for the intervention design (no-interruption zone, medication safety vest) is blue text on a yellow background. The priority groups for education related to medication interruptions were patients or caregivers, nurses, and non-nursing staff, in that order. Conclusion: Effective implementation of tailored intervention strategies that consider the specific characteristics of medication interruptions is crucial for mitigating interruptions and enhancing patient safety. Comprehensive educational programs aimed at reducing medication interruptions by improving awareness are necessary. Moreover, future research should evaluate these strategies in clinical settings to ensure their effectiveness in enhancing patient safety.

Development of an Integrated Electrode-bipolar Plate Assembly with Reduced Contact Resistance for Vanadium Redox Flow Battery (바나듐 레독스 흐름전지용 접촉저항 감소 일체형 전극-분리판 조립체 개발)

  • Amanpreet Kaur;Jun Woo Lim
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.190-196
    • /
    • 2024
  • The bipolar plate is a crucial element of the vanadium redox flow battery (VRFB) as it serves as both the electrical conduit and the structural support for the cell within the VRFB stack. Although, the graphite material is primarily used for the bipolar plate due to its excellent electrical conductivity, a significant limitation of performance of the VRFB is present due to high interfacial contact resistance (ICR) arises between the electrode and bipolar plate in the cell stack. This study aims to develop an integrated electrode-bipolar plate assembly that will address the limitations of the ICR. The integrated assembly was constructed using a single carbon felt with thermoplastic and thermoset polymers utilizing hot press method. Experimental results verify that the bipolar plate assembly exhibits reduced area specific resistance (ASR) due to the continuous electrical path. Additionally, from the charge/discharge cell test results, the integrated assembly shows improved cell performance. Therefore, the developed integrated electrode-bipolar plate assembly can serve as a substitute for the conventional bipolar plate and electrode assembly.

A Study on Integrated Operation of Securities Branch and Customer Center: Focusing on Integrated Operation of IPT and IPCC (증권사 영업점과 고객센터 통합운영에 관한 연구: IPT와 IPCC 통합운영을 중심으로)

  • Jo, Jae-Hyun;Cheong, Ki-Ju
    • Information Systems Review
    • /
    • v.17 no.2
    • /
    • pp.29-48
    • /
    • 2015
  • This study proposes an integrated operational model of branches with customer center at stock brokerage firms and suggests ways to improve existing systems. This suggested integrated model of branches and customer centers can increase customer satisfaction and customer values for the specific services at each channel. This integrated model also enables customers to make transactions at a desired specific time, make it possible to inquire whatever the customer wished to ask, and select desired contact channels. In addition, the firms can bring in improved effectiveness of internal resources by integrating all the resources the firm has. Personal resources and system resources are distributed by the characteristics of channels that can be selected by the customers. Then agents also can provide more speedy and accurate responses to the engaged customer interactions matching to his/her job in charge. Also, the model makes it possible to collect the latest customer and transaction information at the moment of each interactions, by which the firm can provide customized services specifically tailed to each customers' preferences. However, systematic interactions between branches and customer center, and completed system should be equipped with in order to provide the highest quality services.

Mesoporous Carbon Electrodes for Capacitive Deionization (축전식 탈염 공정을 위한 메조포러스 탄소 전극)

  • Lee, Dong-Ju;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.1
    • /
    • pp.57-64
    • /
    • 2014
  • Carbon electrodes for capacitive deionization were fabricated through mixing two different carbon powders (activated carbon powder, carbon black) with different particle sizes to investigate physical or electrochemical properties and finally desalination performances of the electrodes with various compositions of two carbon powders in weight and were compared with the electrode consisting of activated carbon. As a result, the electrode structure became more packed as increasing the amount of carbon black and resulted in 10% increase in mesopore fraction. The specific capacitance obtained from cyclic voltammograms of various electrodes showed that the electrode containing carbon black only had 107.4 F/g, while the specific capacitance of the electrode having more amount of carbon black increased and was higher than the one having no carbon black. The results of desalination runs in a capacitive deionization cell exhibited that the electrode having the highest amount of carbon black (1 wt%) in this study had the highest desalting efficiency, and no significant pH variation was observed during the runs. It was analyzed using accumulated charge that the fraction of non-Faraday current increased as the amount of carbon black increased in the electrodes. It can be concluded that the addition of carbon black changed the electrode structure resulting in an increase in the fraction of mesopore and finally enhanced the desalting efficiency by decreasing Faraday current.

Fabrication and characterization of a Flexible Polyethylene terephthalate (PET) Electrode based on Single-walled carbon nanotubes (SWNTs) (단일벽 탄소나노튜브를 이용한 플렉시블 폴리에틸렌테레프탈레이트 (PET) 전극의 제조와 특성)

  • Du, Jin Feng;Kim, Jang Hun;Kim, Yong Ryeol;Jeong, Hyeon Taek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.587-592
    • /
    • 2016
  • In this study, flexible acid treated single walled carbon nanotubes (A-SWCNTs) electrodes were fabricated by using gold coated PET substrate and spray coating technique. The acid-treatment method was conducted to introduce functional groups on the SWCNTs wall, which could improve dispersability of the SWCNTs and its electrochemical property. The electrochemical properties of flexible A-SWCNTs electrode were carried out by cyclic voltammetry(CV), electrochemical impedance were carried out by cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS) and galvanostatic charge/discharge (GCD) cycles. As a results, The specific capacitance value of the unbent A-SWCNTs electrode was $67F{\cdot}g^{-1}$, which decreased to $63F{\cdot}g^{-1}$ (94% retention) after 1000 GCD cycles. Interestingly, the specific capacitance of the unbent A-SWCNTs electrode with application of the 1000 GCD cycles was retained even after 500 bending to $30^{\circ}$ with 6000 GCD cycles.

Synthesis and characterization of LiMn1.5Ni0.5O4 powders using polymerization complex method (착체중합법을 이용한 LiMn1.5Ni0.5O4 분말합성 및 특성평가)

  • Sin, Jae-Ho;Kim, Jin-Ho;Hwang, Hae-Jin;Kim, Ung-Soo;Cho, Woo-Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.4
    • /
    • pp.194-199
    • /
    • 2012
  • The $LiMn_{1.5}Ni_{0.5}O_4$, substituting a part of Mn with Ni in the $LiMn_2O_4$, the spinel structure has good charge-discharge cycle stability and high discharge capacity at 4.7 V. In this study $LiMn_{1.5}Ni_{0.5}O_4$ powders were synthesized by polymerization complex method. The effect on the characteristics of synthesized $LiMn_{1.5}Ni_{0.5}O_4$ powders was studied with citric acid (CA) : metal ion (ME) molar ratio (5 : 1, 10 : 1, 15 : 1, 30 : 1) and calcination temperature ($500{\sim}900^{\circ}C$). Single phase of $LiMn_{1.5}Ni_{0.5}O_4$ was observed from XRD analysis on the powders calcined at low ($500^{\circ}C$) and high temperatures ($900^{\circ}C$). The crystalline size and crystallinity increased with calcination temperature. At low calcination temperature the particle size decreased and specific surface area increased as the CA molar ratio increased. On the other hand, high particle growth rate at high calcination temperature interfered the particle size reduction and specific surface area increase induced by the increase of CA molar ratio.

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

Comparative Study for Basic Protocol of High Dose Ablation Therapy (고용량 방사성옥소 치료의 기본 Protocol 비교)

  • Moon, Jae-Seung;Jeong, Hee-Il;Lee, Chi-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.147-156
    • /
    • 2008
  • Purpose: All acts which are enforced from the radioactive iodine therapeutic team is a in its own way principle and provision. Therefore unification of all acts can not be appropriately. We will make the standard coherence. Materials & Methods: From 5 November, 2007 to 17 November 2007, we conducted a questionnaire survey of the nuclear medicine manager of 30 hospitals. The contents of a questionnaire is medical treatment section, patient management, prosecuting attorney section, waste management and safety supervision in about the patient and a questionnaire was drawn up in the method which selects an item. Results: 30 hospital agencies are operating purely for I-131 high dose ablation therapy. Diagnostic study and daily schedule had the difference of some. The most of education for the patients took charge of doctor and nurse. The satisfaction of education was evaluated as the high thing. The safety supervision of waste management accomplishment and Safety supervision the patient and the worker observed on the basis of atomic energy law. Conclusion: Specific standards with sufficient amount of information and practical contents should have been presented through the following data. However, it seems to be lacking in many aspects. Nevertheless, respondents rated 70.9%, which is relatively high, on the value of clinical utilization, and I am very thankful for the evaluation. For many years from now, it may seem necessary for a lot of research on the specific matters based on these data to be conducted.

  • PDF