• Title/Summary/Keyword: Special charge

Search Result 230, Processing Time 0.028 seconds

Adaptive State-of-Charge Estimation Method for an Aeronautical Lithium-ion Battery Pack Based on a Reduced Particle-unscented Kalman Filter

  • Wang, Shun-Li;Yu, Chun-Mei;Fernandez, Carlos;Chen, Ming-Jie;Li, Gui-Lin;Liu, Xiao-Han
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1127-1139
    • /
    • 2018
  • A reduced particle-unscented Kalman filter estimation method, along with a splice-equivalent circuit model, is proposed for the state-of-charge estimation of an aeronautical lithium-ion battery pack. The linearization treatment is not required in this method and only a few sigma data points are used, which reduce the computational requirement of state-of-charge estimation. This method also improves the estimation covariance properties by introducing the equilibrium parameter state of balance for the aeronautical lithium-ion battery pack. In addition, the estimation performance is validated by the experimental results. The proposed state-of-charge estimation method exhibits a root-mean-square error value of 1.42% and a mean error value of 4.96%. This method is insensitive to the parameter variation of the splice-equivalent circuit model, and thus, it plays an important role in the popularization and application of the aeronautical lithium-ion battery pack.

A Study on A Spiral Charge for 3 Dimensional Charge Simulation Method (3차원 전하 중첩법용 나선 전하의 특성에 관한 연구)

  • 민석원;박은서;송기현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.31-36
    • /
    • 2001
  • This paper investigates characteristics of spiral charge for 3 dimensional charge simulation method to calculate electric fields of special conductor bundles with spiral rods in 765kV transmission line. We finds the simulating spiral charge as constant charge density give less potential calculation error than sinusoidal charge falsity. When a spiral rod is simulated as spiral charge, we also knows two spiral charge can simulate spiral rod best.

  • PDF

3-Dimensional Analysis II on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise In Corona Cage (코로나 케이지 내부에서의 풍소음 저감용 특수 다중도체 방식의 3차원 전계분포해석 II)

  • Min, Suk-Won;Song, Ki-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.399-402
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was applied to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise in a corona cage. Comparing electric field distributions of special conductor bundles in 765kV transmission tine with ones in corona case, we decide experimental voltages of special conductor bundles in corona cage.

  • PDF

Analysis on Electric Field Distributions and Corona Characteristics of Special Conductor Bundles for 765kV Transmission Line (765kV 송전선로용 특수 다중도체 방식의 코로나 잡음특성 및 전계분포 해석)

  • Min, Seok-Won;Kim, Yong-Jun;Sin, Gu-Yong;Lee, Dong-Il;Ju, Mun-No;Yang, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.12
    • /
    • pp.556-560
    • /
    • 2001
  • To solve aeolian noise, we have tried several special conductor bundles equipped with spiral rod and one kind of low aeolian noise conductor with a special shape. Charge simulation method was applied to analyze electric field distributions of them in transmission line and corona cage for investigating the corona characteristics. This paper describes the electric field distributions and the performances of audible noise and radio interference from the special bundles in 765 kV transmission line by using corona characteristics obtained from corona cage simulation.

  • PDF

A Case Study of Underwater Blasting (수중발파 사례 연구)

  • 정민수;박종호;송영석
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.57-64
    • /
    • 2004
  • There are two major types of underwater blasting at Korea, bridges and harbor construction work. Pier blasting for lay the foundation bridges construction is used dry excavation working (drilling and charging) after pump out water and then fire pump in water that is same as bench blasting. In contrast, underwater blasting for harbor construction and increase of harbor load depth is used to barge with digging equipment that is in oder to drilling on the surface and blasting work(charge, hook-up) under water. Thus, there are need to special concern such as charge method and hook-up method different from tunnel blasting work and bench blasting work. If do not use special concern breaks out dead pressure and mis fire because of there are so many difficult condition such as water pressure, obstruct field of vision. In this study underwater blasting at Busan Harbor Construction have consider with special concern that is plastic pipe charge method used to MegaMITE I and specialized buoy hook- up method make far initial system detonate on the surface used to TLD. The results is designed blast pattern charge per delay effect an inspection of verify between predict velocity and measure velocity. minimized break out mis fire consideration charge method, hook up method. According to result best underwater blasting design is 105mm drilling dia, MeGAMITE II, HiNLL Plus(non electric detonator).

Control of $NaAlSiO_4:Eu^{2+}$ photoluminescence properties by charge-compensated aliovalent element substitutions

  • Kim, Jihae;Kato, Hideki;Kakihana, Masato
    • Journal of Information Display
    • /
    • v.13 no.3
    • /
    • pp.97-100
    • /
    • 2012
  • We have conducted two kinds of the so-called charge-compensated aliovalent element substitutions to control the photoluminescence properties of $NaAlSiO_4:Eu^{2+}$ with a special focus on the enhancement of the excitation intensity at 400 nm. The aliovalent element substitutions include cation-cation and cation-anion co-substitutions according to the general formulas $Na_{1-x}M_xAl_{1+x}Si_{1-x}O_4:Eu^{2+}$ and $Na_{1-x}M_xAlSiO_{4-x}N_x:Eu^{2+}$ (M = $Mg^{2+}$, $Ca^{2+}$, and $Sr^{2+}$), respectively. The increase in the relative excitation intensity at 400 nm has been achieved in both types of the co-substitutions. Thus, the present research has demonstrated the effectiveness of the charge-compensated element substitution.

A Study on Economic Analysis Algorithm for Energy Storage System Considering Peak Reduction and a Special Tariff (피크저감과 특례요금제를 고려한 ESS 경제성 분석 알고리즘에 관한 연구)

  • Son, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1278-1285
    • /
    • 2018
  • For saving electricity bill, energy storage system(ESS) is being installed in factories, public building and commercial building with a Time-of-Use(TOU) tariff which consists of demand charge(KRW/kW) and energy charge(KRW/kWh). However, both of peak reduction and ESS special tariff are not considered in an analysis of initial cost payback period(ICPP) on ESS. Since it is difficult to reflect base rate by an amount of uncertain peak demand reduction during mid-peak and on-peak periods in the future days. Therefore, the ICPP on ESS can be increased. Based on this background, this paper presents the advanced analysis method for the ICPP on ESS. In the proposed algorithm, the representative days of monthly electricity consumption pattern for the amount of peak reduction can be found by the k­means clustering algorithm. Moreover, the total expected energy costs of representative days are minimized by optimal daily ESS operation considering both peak reduction and the special tariff through a mixed-integer linear programming(MILP). And then, the amount of peak reduction becomes a value that the sum of the expected energy costs for 12 months is maximum. The annual benefit cost is decided by the amount of annual peak reduction. Two simulation cases are considered in this study, which one only considers the special tariff and another considers both of the special tariff and amount of peak reduction. The ICPP in the proposed method is shortened by 18 months compared to the conventional method.

3-Dimensional Analysis on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise (풍소음 저감용 특수 다중도체 방식의 3차원 전계해석)

  • Min, Suk-Won;Song, Ki-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.254-258
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was developed to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise. When we applied this method to 765 kV double circuit transmission line, we found calculation error of this method was within a reasonable boundary of 1%.

  • PDF

3-Dimensional Analysis on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise In Corona Cage (코로나 케이지 내부에서의 풍소음 저감용 특수 다중도체 방식의 3차원 전계분포해석)

  • Min, Suk-Won;Song, Ki-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.359-361
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was applied to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise in a corona cage. We found calculation error of this method was w a reasonable boundary of 0.5%.

  • PDF

A Study on the Thermal Performance of a Z-shaped Heat Pipe (Z자 형상을 갖는 히트파이프에 대한 열성능 연구)

  • Park, S.Y.;Boo, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.741-745
    • /
    • 2001
  • The necessity of a Z-shape heat pipe may occur in a special application such as a cooling module for an electronic equipment having a limited accessible space. Either of the two end part works as evaporator or condenser and the length of the middle part is 200mm. The heat pipe was made of 3/8 inch copper tube having 60 spiral groove with screw angle of 10 degrees. Water and acetone were used as working fluids. The fill charge ratio of the working fluid was varied for different values of thermal loads. The thermal resistance was calculated based on the temperature measurements along the heat pipe axis. The maximum thermal loads were 80W for water and 100W for acetone heat pipe. The optimum fill charge ratio was identified through a series of experiments.

  • PDF