The necessity of a Z-shape heat pipe may occur in a special application such as a cooling module for an electronic equipment having a limited accessible space. Either of the two end part works as evaporator or condenser and the length of the middle part is 200mm. The heat pipe was made of 3/8 inch copper tube having 60 spiral groove with screw angle of 10 degrees. Water and acetone were used as working fluids. The fill charge ratio of the working fluid was varied for different values of thermal loads. The thermal resistance was calculated based on the temperature measurements along the heat pipe axis. The maximum thermal loads were 80W for water and 100W for acetone heat pipe. The optimum fill charge ratio was identified through a series of experiments.