• Title/Summary/Keyword: Space vector pulse width

Search Result 146, Processing Time 0.029 seconds

The Stabilized Speed Control Modeling of Single-side Linear Induction Motor Considering End-effect (단부효과가 고려된 편측형 선형유도전동기의 안정속도제어 모델링)

  • Lim, Hong-Woo;Chae, Bong;Choi, Moon-Han;Lee, Kang-Yeon;Cho, Geum-Bae;Baek, Hyung-Lae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.266-273
    • /
    • 2006
  • In difference with the rotary type electrical machinery, the single-sided linear induction motor(SLIM) that generates the direct thrust, is widely used for the operation system of electrified railroad, lope-less elevation system, conveyer system, and so on. The operational principle of single-sided linear induction motor is constructively similar to the general rotary Induction motor It Is difficult to realize the complicate linear induction motor which is applied space vector pulse width modulation(SVPWM) system, but widely used in vector motor control system or servo control system because of its high performance in current control. In this paper, we has modeled the dynamic characteristic analyzing methode, and calculated efficiently the end effect by using equivalent circuit methode in the operating linear Induction motor control system.

Speed-Sensorless Induction Motor Control System using a Rotor Speed Compensation (회전자 속도보상을 이용한 센서리스 유도전동기 제어 시스템)

  • Jeong Gang-Youl
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.3
    • /
    • pp.154-161
    • /
    • 2005
  • This paper proposes a speed-sensorless induction motor control system using a rotor speed compensation. To explain the proposed system, this paper describes an induction motor model in the synchronous reference frame for the vector control. The rotor flux is estimated by the rotor flux observer using the reduced-dimensional state estimator technique. The estimated rotor speed is directly obtained from the electrical frequency, the slip frequency, and the rotor speed compensation with the estimated q-axis rotor flux. The error of the rotor time constant is indirectly reflected in the rotor speed compensation using the compensation of the flux error angle. To precisely estimate the rotor flux, the actual value of the stator resistance, whose actual variation is reflected, is derived. An implementation of pulse-width modulation (PWM) pulses using an effective space vector modulation (SVM) is briefly mentioned. For fast calculation and improved performance of the proposed algorithm, all control functions are implemented in software using a digital signal processor (DSP) with its environmental circuits. Also, it is shown through experimental results that the proposed system gives good performance for the speed-sensorless induction motor control.

Design of DSP(TMS320F240) Controller for Multi-axes Transportation System with BLDC Servo Motor (DSP(TMS320F240)를 이용한 BLDC서보 전동기 다축 이송시스템 제어기 설계)

  • 김민섭;구효원;최중경;권현아;신영호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.95-98
    • /
    • 2002
  • This paper presents a study on DSP(TMS320F240) controller design for multi-axes transportation system using BLDC servo motor. This BLDC servo motor controller was realized with DSP(Digital Signal Processor) and IPM (Intelligent Power Module). The multi-axes transportation system needs torque, speed, position control of servo motor for variable action. This paper implements those servo control with vector control and space vector modulation technique. As CPU of controller DSP(TMS320F240) is adopted because, it has PWM(Pulse Width Modulation) waveform generator, A/D(Analog to Digital) converter, SPI(Serial Peripheral Interface) port and input/output port etc. The controller of multi-axes transportation system consists of 3-level hierarchy structure that main host PC manages three sub DSP system which transfer downword command and are monitoring the states of end servo controllers. Each sub DSP system operates eight BLDC servo controllers which control BLDC servo motor using DSP and IPM Between host system and middle digital signal processor communicate with RS-422, between main processor and controller communicate with SPI port.

  • PDF

Neuro-Fuzzy Controller Design of DSP for Real-time control of 3-Phase induction motors (3상 유도전동기의 실시간 제어를 위한 DSP의 뉴로-퍼지 제어기 설계)

  • Lim, Tae-Woo;Kang, Hack-Su;Ahn, Tae-Chon;Yoon, Yang-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2286-2288
    • /
    • 2001
  • In this paper, a drive system of induction motor with high performance is realized on the viewpoint of the design and experiment, using the DSP (TMS320F240). The speed controller for induction motor drive system is designed on the basis of a neuro-fuzzy network. The neuro-fuzzy controller acts as a feed-forward controller that provides the right control input for the plant and accomplishes error back-propagation algorithm through the network. The proposed network is used to achieve the high speedy calculation of the space vector PWM (Pulse Width Modulation) and to build the neuro-fuzzy control algorithm, for the real-time control. The proposed neuro-fuzzy algorithm on the basis of DSP shows that experimental results have good performance for the precise speed control of an induction motor drive system. It is confirmed that the proposed controller could provide more improved control performance than conventional v/f vector controllers through the experiment.

  • PDF

An Implementation of a Hall Sensor position compensation algorithm for the Muli-pole Type BLDC motor driving with the DSP(TMS320F28335). (DSP(TMS320F28335)를 이용하는 다극 BLDC 전동기 구동을 위한 홀센서 절대위치 보정 알고리즘 구현법)

  • Park, Jun-ho;Lim, Dong-gyun;Choi, Jung-keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.391-394
    • /
    • 2014
  • In this paper, we introduce a method of determining the absolute position of the rotor for the vector control of Hall sensor type multi-pole BLDC motor using the DSP(TMS320F28335), and implement an algorithm to complement the problems of the conventional method. The switching method of the inverter for providing desired sinusoidal current to each phase of a motor, we adopt Space-Vector pulse width modulation method. In order to increase the speed range, Field-Weakness control method are used. In order to verify the proposed algorithm, we compare the value of Iqe, Ide and phase currents with the values before compensated.

  • PDF

Near-Five-Vector SVPWM Algorithm for Five-Phase Six-Leg Inverters under Unbalanced Load Conditions

  • Zheng, Ping;Wang, Pengfei;Sui, Yi;Tong, Chengde;Wu, Fan;Li, Tiecai
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.61-73
    • /
    • 2014
  • Multiphase machines are characterized by high power density, enhanced fault-tolerant capacity, and low torque pulsation. For a voltage source inverter supplied multiphase machine, the probability of load imbalances becomes greater and unwanted low-order stator voltage harmonics occur. This paper deals with the PWM control of multiphase inverters under unbalanced load conditions and it proposes a novel near-five-vector SVPWM algorithm based on the five-phase six-leg inverter. The proposed algorithm can output symmetrical phase voltages under unbalanced load conditions, which is not possible for the conventional SVPWM algorithms based on the five-phase five-leg inverters. The cause of extra harmonics in the phase voltages is analyzed, and an xy coordinate system orthogonal to the ${\alpha}{\beta}z$ coordinate system is introduced to eliminate low-order harmonics in the output phase voltages. Moreover, the digital implementation of the near-five-vector SVPWM algorithm is discussed, and the optimal approach with reduced complexity and low execution time is elaborated. A comparison of the proposed algorithm and other existing PWM algorithms is provided, and the pros and cons of the proposed algorithm are concluded. Simulation and experimental results are also given. It is shown that the proposed algorithm works well under unbalanced load conditions. However, its maximum modulation index is reduced by 5.15% in the linear modulation region, and its algorithm complexity and memory requirement increase. The basic principle in this paper can be easily extended to other inverters with different phase numbers.

Frequency Synchronization of Three-Phase Grid-Connected Inverters Controlled as Current Supplies

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin;Yin, Jing
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1347-1356
    • /
    • 2018
  • In a three-phase system, three-phase AC signals can be translated into two-phase DC signals through a coordinate transformation. Thus, the PI regulator can realize a zero steady-state error for the DC signals. In the control of a three-phase grid-connected inverter, the phase angle of grid is normally detected by a phase-locked loop (PLL) and takes part in a coordinate transformation. A novel control strategy for a three-phase grid-connected inverter with a frequency-locked loop (FLL) based on coordinate transformation is proposed in this paper. The inverter is controlled as a current supply. The grid angle, which takes part in the coordinate transformation, is replaced by a periodic linear changing angle from $-{\pi}$ to ${\pi}$. The changing angle has the same frequency but a different phase than the grid angle. The frequency of the changing angle tracks the grid frequency by the negative feedback of the reactive power, which forms a FLL. The control strategy applies to non-ideal grids and it is a lot simpler than the control strategies with a PLL that are applied to non-ideal grids. The structure of the FLL is established. The principle and advantages of the proposed control strategy are discussed. The theoretical analysis is confirmed by experimental results.

Photovoltaic Generation System Control Using Space Vector PWM Method (공간벡터 PWM 방식을 이용한 태양광 발전 시스템 제어)

  • Cho, Moon-Taek;Choi, Hae-Gill;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.31-37
    • /
    • 2010
  • In this paper, a photovoltaic system is designed with PWM(Pulse Width Modulation) voltage source inverter. Proposed synchronous signal and control signal was processed by 56F8323 microprocessor for stable modulation. The PWM voltage source inverter using inverter consists of complex type of electric power converter to compensate for the defect, that is solar cell cannot be developed continuously by connecting with the source of electric power for ordinary use. It can cause the effect of saving electric power, from 10 to 20[%]. The PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. In addition, I connected extra power to the system through operation the system voltage and inverter power in a synchronized way by extracting the system voltage so that the phase of the system and PWM voltage inverter can be synchronized. In the system of this research showed good results after being controlled in order to provide stable power to the load and the system through maintaining and low output power of harmonics.

Comparative Study of Minimum Ripple Switching Loss PWM Hybrid Sequences for Two-level VSI Drives

  • Vivek, G.;Biswas, Jayanta;Nair, Meenu D.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1729-1750
    • /
    • 2018
  • Voltage source inverters (VSIs) are widely used to drive induction motors in industry applications. The quality of output waveforms depends on the switching sequences used in pulse width modulation (PWM). In this work, all existing optimal space vector pulse width modulation (SVPWM) switching strategies are studied. The performance of existing SVPWM switching strategies is optimized to realize a tradeoff between quality of output waveforms and switching losses. This study generalizes the existing optimal switching sequences for total harmonic distortions (THDs) and switching losses for different modulation indexes and reference angles with a parameter called quality factor. This factor provides a common platform in which the THDs and switching losses of different SVPWM techniques can be compared. The optimal spatial distribution of each sequence is derived on the basis of the quality factor to minimize harmonic current distortions and switching losses in a sector; the result is the minimum ripple loss SVPWM (MRSLPWM). By employing the sequences from optimized switching maps, the proposed method can simultaneously reduce THDs and switching losses. Two hybrid SVPWM techniques are proposed to reduce line current distortions and switching losses in motor drives. The proposed hybrid SVPWM strategies are MRSLPWM 30 and MRSLPWM 90. With a low-cost PIC microcontroller (PIC18F452), the proposed hybrid SVPWM techniques and the quality of output waveforms are experimentally validated on a 2 kVA VSI based on a three-phase two-level insulated gate bipolar transistor.

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.