Measurement of Ceiling Temperature in Tunnel for Heights and Fire Sizes of Fire Source (화원의 높이 및 화재크기별 터널 천장온도 측정 실험)

  • Park, Won-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.5-10
    • /
    • 2015
  • The "Ondong tunnel" is not used now where is one of the tunnels in the Janghang line which is from Cheonan to Iksan. The length of the tunnel is 214 m. The location of the fire source is center of the tunnel and the pool fire with heptane is for the fire source. Tests are carried out for the various fire sizes, the height and obstructed/open condition of the fire source. Temperature on the top of the tunnel is measured. Even if the fire size is same, the maximum temperature on the ceiling of the tunnel for the elevated fire source is very larger than the maximum for the ground fire source. As the fire size is lager the maximum temperature on the ceiling is higher. These test results can be very useful for design and guidelines of fire detectors in tunnels.

A study of Heat Transfer by the Finite Element Method - Around Square Heat Source - (유한요소법에 의한 열전달 연구 -4각열원 주위-)

  • 장재은
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.26-33
    • /
    • 1998
  • This paper subdivided the interior solid into triangular shape of equal size to calculate the temperature distribution around the square heat source of it, and compared calculated values with measured ones. The result obtained are as follows. 1) It was found that we can calculate the temperature distribution around the square heat source of interior solid by the variational method of the finite element method as the calculated values were almost accord with the measured ones. 2) The temperature distributed were higher when the distances between heat source were farther and lower when those nearer. 3) Vertical surface temperature distribution is remarkably efficient by thermal conductivities.

  • PDF

Study on Organic Rankine Cycle (ORC) for Maximum Power Extraction from Low-Temperature Energy Source (저온 열원으로부터 최대 동력을 생산하기 위한 유기랭킨사이클(ORC)에 관한 연구)

  • Kim, Kyoung-Hoon;Han, Chul-Ho;Kim, Gi-Man
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.73-79
    • /
    • 2011
  • ORC(organic Rankine cycle) has potential of reducing consumption of fossil fuels and has many favorable characteristics to exploit low-temperature heat sources. This work analyzes performance of ORC with superheating using low-temperature energy sources in the form of sensible energy. Maximum mass flow rate of a working fluid relative to that of a source fluid is considerd to extract maximum power from the sources. Working fluids of R134a, $iC_4H_{10}$ and $C_6C_6$, and source temperatures of $120^{\circ}C$, $200^{\circ}C$ and $300^{\circ}C$ are considered in this work. Results show that for a fixed source temperature thermal efficiency increases with evaporating temperaure, however net work per unit mass of source fluid has a maximum with respect to the evaporating temperature in the range of low source temperature. Results also show that the maximum power extraction is possible with R134a for the source temperature of $120^{\circ}C$, with $iC_4H_{10}$ for $200^{\circ}C$, and with $C_6C_6$ for $300^{\circ}C$.

Study on the Heat Generation Characteristics of the Carbon Heating Source with High Temperature (고온 카본발열체의 발열특성에 관한 연구)

  • Bae, K.Y.;Lee, K.S.;Shin, J.H.;Jeong, H.M.;Chung, H.S.;Chun, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.106-111
    • /
    • 2001
  • This paper is a study on the heat generation characteristics of the carbon heating source with high temperature. The main variables of this study are the input current and the amount of carbon heating source. As the results of the experiment in the waste rate of carbon heating source. The case of carbon heating source 300g was large than 500g. As the input current and the temperature are increased, the resistance values of carbon heating source were large. The Joule heat was represented the large value as the amount of heating source decrease with the input current. Finally, the heating source was represented the electrical steady state as the input current is increase.

  • PDF

A Study on the Electrical and Optical Properties of CdS Thin Films Deposited with Different Conditions for Solar Cell Applications (태양전지용 CdS 박막의 제조 조건에 따른 전기적 광학적 특성에 관한 연구)

  • Lee, Jae-Hyeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.7
    • /
    • pp.620-628
    • /
    • 2008
  • Cadmium sulphide (CdS) thin film, which is used as a window layer of heterojunction solar cell, on the glass substrate was deposited by vacuum evaporation. Effects of deposition conditions such as the source and substrate temperature on electrical and optical properties of CdS films was investigated. As the source temperature was increased, the deposition rate of CdS films was increased. In addition, the optical transmittance and the electrical resistivity of CdS films were decreased as the source temperature was increased. This results were attributed to the increase of excess Cd amount in the film. The crystal structure of CdS films exhibited the hexagonal phase with preferential orientation of the (002) plane. As the substrate temperature was increased, the crystal structure of CdS films was improved and the resistivity of the films was increased due to the decrease of excess Cd in film.

Study on the Partially Premixed Flames Produced by a Coflow Burner as Temperature Calibration Source (동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구)

  • Park, Chul-Woung;Hahn, Jae-Won;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a co flow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF

Temperature Evaluation on Long-term Storage of Radioactive Waste Produced in the Process of Isotope Production (동위원소 생산공정에서 발생한 방사성 폐기물 장기저장소 온도평가)

  • Jeong, Namgyun;Jo, Daeseong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.7
    • /
    • pp.471-475
    • /
    • 2016
  • In the present study, temperature evaluations on long-term storage of radioactive waste produced in the process of isotope production were performed using two different methods. Three-dimensional analysis was carried out assuming a volumetric heat source, while two-dimensional studies were performed assuming a point source. The maximum temperature difference between the predictions of the volumetric and point source models was approximately $5^{\circ}C$. For the conceptual design level, a point source model may be suitable to obtain the overall temperature characteristics of different loading locations. For more detailed analysis, the model with the volumetric source may be applicable to optimize the loading pattern in order to obtain minimum temperatures.

Study on Economic analysis and Dessemination Policy of Unused Energy (미활용에너지의 경제적 효과 및 보급지원방안 연구)

  • An, Hyung-Jun;Baek, Sung-Kwon;Heo, Eunn-Yeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.95-98
    • /
    • 2008
  • Temperature difference energy is a good energy source replacing the fossil fuels. In the study, we classified the temperature difference energy as 4 types by the source & using method. For the understanding economic property of temperature difference energy, we tried simle economic analysis. As the result, Pay back period of 4 case of the temperature difference energy are from 1.23 to 12.65 years. Major factors influenced economic effect are operation time and energy user distance from the temperature difference energy source. If we can select optimal capacity and look for more effient energy users, Temperature difference energy play a important role of replacing fossil energy. So, for dess emination of temperature difference energy, we suggest that temperature difference energy must be included in renewable energy. Applying the effective methods among various promotion program of renewable energy policy, utilization of temperature difference energy could be activated.

  • PDF

Prediction of A Rise in Temperature Distribution of Mold Transformer for Power Distribution System (배전용 몰드변압기에 대한 상승 온도 분포 예측)

  • Lee, Jeong-Keun;Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.391-394
    • /
    • 2009
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 2 MVA distribution mold transformer using finite element method (FEM). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage winding and low-voltage winding of mold transformer and Joule's loss of core for improvement these life, forecasted heat source, and high-voltage winding and low-voltage winding of mold transformer and rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the result Also, calculated temperature rise limit of mold transformer and permission maximum temperature using analysis by electron miracle heat source alculate and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

  • PDF

An Experimental Study on the Part-Load Performance of a River Water Source 2-Stage Heat Pump (하천수 열원 2단 압축 열펌프시스템의 부분부하 운전특성에 관한 실험적 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Ra, Ho-Sang
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1964-1968
    • /
    • 2007
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. Although its better performance, the large temperature difference between load and source makes system performance worse by nature. In this study, 2-stage compression is considered as the solution of this problem. Generally, heat pump is designed for maximum capacity rate, but it actually operates at part load condition in many cases. Therefore, an information on the part-load character is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes. The experimental results show that the system performance is influenced by the part load rates, river water temperature, load temperature, etc.

  • PDF