• 제목/요약/키워드: Source impedance

Search Result 378, Processing Time 0.03 seconds

Calculation Method of Transient Potential Rises of Horizontal Ground Electrodes Depending on Injection Point of the Ground Current (접지전류의 입사점에 따른 정보통신설비용 수평접지전극의 과도전위상승 계산 방법)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.197-203
    • /
    • 2014
  • When the lightning current is injected to the ground system of information and communication facilities, analysis of the transient potential rise in the ground system is one of main factors to effectively design the ground system. The performance of grounding systems is normally estimated with the grounding impedance and the transient potential rise which represents the electrical characteristics of the grounding system. The method for calculating the grounding impedance depending on the injection point of the lightning current was proposed. The delta-gap source model was proposed to calculate the grounding impedance in the case that the lightning current is injected to the center of the horizontal ground electrode. A new program which is possible to apply the frequency-dependent soil parameters using the Debye model was developed, because a commercial program for analyzing the performance of the grounding system can not apply to the frequency-dependent soil parameters. The experiment was carried out to confirm the availability of the simulation results with the same condition. Finally, the transient potential rises of a horizontal ground electrode depending on the lightning current waveforms were analyzed by using the results of the grounding impedance which is associated with the frequency-dependent soil parameters.

Bq-ZSI fed Induction Motor Drive System Using Modified Space Vector Modulation (변형 공간벡터 변조 기법이 적용된 Bq-ZSI를 이용한 유도전동기 구동시스템)

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2018
  • This study investigates a bidirectional quasi-Z-source inverter (Bq-ZSI) system with bidirectional power transfer capability and a modified space vector modulation scheme for reducing the ripple of the inductor current. By replacing the diode in the impedance network with an active switch, the power flow can be bidirectional. The average inductor current of the Bq-ZSI network is negative in the regenerative braking mode, thereby regenerating the power. In addition, modified space vector modulation scheme is applied to the Bq-ZSI to control shoot-through time effectively. A 5 kW prototype is built and tested to implement the proposed system. Experimental results show that the Bq-ZSI system is capable of regenerative braking of the induction motor and that the modified space vector modulation method is efficient.

On the selection of loads in the multi-load method for measuring in-duct source characteristics (덕트 내 음원 특성 측정을 위한 다중부하법의 부하 선택에 관한 연구)

  • Jang, Seung-Ho;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.384-388
    • /
    • 2000
  • One-port acoustic characteristics of an in-duct source can be measured by the multi-load method using an overdetermined set of open pipes with different lengths as applied loads. The input data. viz. load pressure and load impedance, are usually contaminated by measurement error in the actual measurements, which result in errors in the calculated source parameters. In this paper, the effects of the errors in the input data on the results have been studied numerically, varying the number of loads and their impedances in order to determine what combination of the loads will yield the best result. An error analysis is applied to each case of possible loads, which consist of open pipes. It is noted that, frequently, only a set of open pipes is used when applying the multi-load method to the intake or exhaust sides of internal combustion engines. A set of pipe lengths which cause the calculated results to be least sensitive to the input data error can be found when using open pipe loads. The present work is intended to produce guidelines for preparing an appropriate load set in order to obtain accurate source properties of fluid machines.

  • PDF

Acoustic emission localization in concrete using a wireless air-coupled monitoring system

  • Yunshan Bai;Yuanxue Liu;Guangjian Gao;Shuang Su
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.195-205
    • /
    • 2023
  • The contact acoustic emission (AE) monitoring system is time-consuming and costly for monitoring concrete structures in large scope, in addition, the great difference in acoustic impedance between air and concrete makes the detection process inconvenient. In this work, we broaden the conventional AE source localization method for concrete to the non-contact (air-coupled) micro-electromechanical system (MEMS) microphones array, which collects the energy-rich leaky Rayleigh waves, instead of the relatively weak P-wave. Finite element method was used for the numerical simulations, it is shown that the propagation velocity of leaky Rayleigh waves traveling along the air-concrete interface agrees with the corresponding theoretical properties of Lamb wave modes in an infinite concrete slab. This structures the basis for implementing a non-contact AE source location approach. Based on the experience gained from numerical studies, experimental studies on the proposed air-coupled AE source location in concrete slabs are carried out. Finally, it is shown that the locating map of AE source can be determined using the proposed system, and the accuracy is sufficient for most field monitoring applications on large plate-like concrete structures, such as tunnel lining and bridge deck.

Adjustable-Performace, Single-Ended Input Double-Balanced Mixer

  • Choi, Jin-Yong;Lee, Kyung-Ho;Lee, Sang-Gug
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.248-252
    • /
    • 2001
  • A noble single-ended input, double-balanced mixer topology is proposed. The mixer incorporates the common-source amplifier input stage with inductive degeneration for impedance matching. The analysis based on simulations shows that the overall performance of the mixer is excellent and is adjustable by varying the input transistor size to give best characteristics for the given linearity specifications.

  • PDF

Signal Reflection Elimination Technique for Interconnects in Digital System (디지털시스템 내의 연결선에서 발생하는 신호 반사 제거 기법)

  • Sung, Bang-Hyun;Noh, Kyung-Woo;Baek, Jong-Humn;Kim, Seok-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.416-420
    • /
    • 2008
  • This paper proposes a new method to improve signal characteristics at branches frequently met in system-level routing. We also introduce the numerical formula which can estimate the time delay due to branches and the simple design guideline for system-level routing. Finally, we propose the routing method which can eliminate the signal reflection for the case of one driver and two receivers (multi-drop topology).

TRV analysis by using multi - port equivalent (다 단자망 축약 이론을 이용한 TRV 해석)

  • Yoon, Jae-Young;Moon, Young-Hyun;Park, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.236-240
    • /
    • 1988
  • The simplified equivalent by using the short circuit impedance has been used for analyzing the prospective transient recovery voltage of the large power system. But it sometimes generates untorelable error in the rate-of-rise of TRV when using the Thevenin equivalent source. This paper provides the new equivalent by using the multi-port theory. The application of the new method to the sample system gives satisfactory accuracy compared with the short-circuit equivalent.

  • PDF

Electrical Properties of TiO$_2$dopen ZnO (TiO$_2$가 첨가된 ZnO의 전기적성질)

  • 최우성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.22-24
    • /
    • 1995
  • The electrical conductivity of TiO$_2$doped ZnO was investigated by means of complex impedance measurement and voltage-current source and meaurement unit. The e1ectrical conductivity of TiO$_2$added ZnO was increased with increasing the concentration of TiO$_2$. The calculated relative dielectric constant was decreased with increasing the concentration of TiO$_2$. The increase of electrical conductivity seems to be the effect of TiO$_2$donor doping.

  • PDF

Input impedance analysis of the coaxial to W/G type devices (동축전송선로에 연결된 도파관형 소자의 입력 임피던스 해석)

  • 이평화;천창율;신판석
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.11
    • /
    • pp.9-19
    • /
    • 1997
  • By noticing that most waveguide devices were connected to power source through coaxial line, three dimentional finite element analysis using TEM mode incident was tried. When tEM mode was used, being dissimilar to TE$_{10}$ mode incident, analysis model of TEM mode incident has almost the same geometry with real products. Therefore, the degree of trust about analysis result is improved. Reflection coefficients of coaxial line, W/G adaptor, magnetron obtained by simulation was compared with experimental results.

  • PDF

Shielding Effectiveness of Mesh Screen Filter of Plasma Display Panel

  • Lim, Heon-Yong;Kim, Min-Seok;Lee, Jeong-Hae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.568-570
    • /
    • 2004
  • A shielding effectiveness of mesh screen filter of plasma display panel (PDP) has been calculated in this paper. Since the screen filter is located near the radiation source, the near field wave impedance of the radiation source, i.e., the PDP electrodes, has been considered to calculate the shielding effectiveness. The near field shielding effectiveness of screen filter at 30${\sim}$300 MHz has been estimated to be more than 65${\sim}$80 dB. The measured shielding effectiveness of screen filter is 10${\sim}$50 dB at 30${\sim}$300 MHz[1]. The resulting discrepancy indicates that there are other EMI emission sources such as emission from PCB and cable besides the PDP electrodes.

  • PDF