• Title/Summary/Keyword: Source Scan Flow

Search Result 9, Processing Time 0.029 seconds

Fabrication of NiO buffer film on textured Ni substrate for YBCO coated conductor (Textured Ni 기판 위에 YBCO coated conductor 모재용 NiO 완충층 제조)

  • Sun, Jong-Won;Kim, Hyoung-Seop;Jung, Choon-Ghwan;Lee, Hee-Gyoun
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.125-129
    • /
    • 2001
  • NiO buffer layers were deposited on texture Ni tapes fur YBCO coated conductors by MOCVD(metal organic chemical vapor deposition) method, using a single solution source. Variables were deposition temperature and flow rate of $0_2$carrier gas. At higher temperatures, The NiO(111) texture was well developed, but the NiO(200) texture was developed at low temperatures. The best result was obtained at the deposition temperature of$ 470^{\circ}C$ and the gas flow rate of 200 sccm. FWHM value of $\omega$-scan fur NiO(200) of the film and $\Phi$-scan for NiO(111) of the film was $4.2^{\circ}$ and $7^{\circ}$, respectively.

  • PDF

High Speed Etching for Saw Damage Removal Using by RF DBD

  • Go, Min-Guk;Yang, Jong-Geun;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.139.2-139.2
    • /
    • 2013
  • 6" Multi-crystal Silicon wafer has etched suing a remote - type RF Dielectric barrier discharge (RF DBD) at atmospheric pressure. DBD source is composed of Al electrode and coated Al2O3 dielectric as function of Ar/NF3 gas combination and input power used 13.56 MHz power supply. Ar gas flow rate is changed from 2 to 10 Slm, and NF3 flow rate is changed from 0.2~1 slm. At the result, NF3 flow rate Si etching rate also increase whit the increasing of NF3 flow rate But at 2 slm etching rate was decrease. In this experience, Max etching rate is 2.3 ${\mu}m/min$ when the scan time is 45 sec.

  • PDF

A Device of Static Buffer Overflow Detection by using Function Summary and Tracking Information Flow of Buffer Domain (함수요약 및 버퍼의 도메인 정보흐름 추적에 의한 정적 버퍼넘침 탐지방안)

  • Lee, Hyung-Bong;Park, Jeong-Hyun;Park, Hyun-Mee
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.6
    • /
    • pp.703-714
    • /
    • 2001
  • In C language, a local buffer overflow in stack can destroy control information stored near the buffer. In case the buffer overflow is used maliciously to overwrite the stored return address, the system is exposed to serious security vulnerabilities. This paper analyzes the process of buffer overflow hacking and methodologies to avoid the attacks in details. And it proposes a device of static buffer overflow detection by using function summary and tracking information flow of buffer domain at assembly source code level(SASS, Static Assembly Source code Scanner) and then show the feasibility and validity of it by implementing a prototype in Pentium based Linux environment.

  • PDF

Deposition and Electrical Properties of Al2O3와 HfO2 Films Deposited by a New Technique of Proximity-Scan ALD (PS-ALD) (Proximity-Scan ALD (PS-ALD) 에 의한 Al2O3와 HfO2 박막증착 기술 및 박막의 전기적 특성)

  • Kwon, Yong-Soo;Lee, Mi-Young;Oh, Jae-Eung
    • Korean Journal of Materials Research
    • /
    • v.18 no.3
    • /
    • pp.148-152
    • /
    • 2008
  • A new cost-effective atomic layer deposition (ALD) technique, known as Proximity-Scan ALD (PS-ALD) was developed and its benefits were demonstrated by depositing $Al_2O_3$ and $HfO_2$ thin films using TMA and TEMAHf, respectively, as precursors. The system is consisted of two separate injectors for precursors and reactants that are placed near a heated substrate at a proximity of less than 1 cm. The bell-shaped injector chamber separated but close to the substrate forms a local chamber, maintaining higher pressure compared to the rest of chamber. Therefore, a system configuration with a rotating substrate gives the typical sequential deposition process of ALD under a continuous source flow without the need for gas switching. As the pressure required for the deposition is achieved in a small local volume, the need for an expensive metal organic (MO) source is reduced by a factor of approximately 100 concerning the volume ratio of local to total chambers. Under an optimized deposition condition, the deposition rates of $Al_2O_3$ and $HfO_2$ were $1.3\;{\AA}/cycle$ and $0.75\;{\AA}/cycle$, respectively, with dielectric constants of 9.4 and 23. A relatively short cycle time ($5{\sim}10\;sec$) due to the lack of the time-consuming "purging and pumping" process and the capability of multi-wafer processing of the proposed technology offer a very high through-put in addition to a lower cost.

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.

In-service Investigation on the Flow Dynamics of a Trayed Column from the Measurement of an Internal Density by using a Gamma Absorption Technique (Gamma Absorption Technique를 이용한 Trayed Column의 가동 중 내부 밀도분포 측정에 의한 유체 유동상태 진단)

  • Kim, Jae-Ho;Kim, Jong-Bum;Kim, Jin-Seop;Lee, Na-Young;Lee, Sung-Sik;Jang, Seok-Joon;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • A distillation tower is one of the important facilities which separates and refines a crude oil stream according to certain boiling points. Its operation efficiency can affect the productivity of a refinery substantially. The objective of this study is to elucidate some operational information on the internal conditions of a distillation tower from a measurement of density profile by using a sealed gamma-ray source and a radiation detector. Gamma radiation counts were measured by a BGO detector positioned diametrically outside the tower-wall, opposite to the gamma source(Co-60) as the detector and the source were lowered concurrently. From the results, structural abnormality of the trays was not found inside the tower. Considering the flow distribution patterns, however, a vapor phase was dominantly formed at the upper part of the tower and a liquid phase at the lower part. From the gamma scanning of the distillation tower, it is anticipated that the gamma absorption technique can be used as an important tool for confirming the structural soundness of trays and investigating flow distribution in refinery facilities.

An Algorithm to Detect P2P Heavy Traffic based on Flow Transport Characteristics (플로우 전달 특성 기반의 P2P 헤비 트래픽 검출 알고리즘)

  • Choi, Byeong-Geol;Lee, Si-Young;Seo, Yeong-Il;Yu, Zhibin;Jun, Jae-Hyun;Kim, Sung-Ho
    • Journal of KIISE:Information Networking
    • /
    • v.37 no.5
    • /
    • pp.317-326
    • /
    • 2010
  • Nowadays, transmission bandwidth for network traffic is increasing and the type is varied such as peer-to-peer (PZP), real-time video, and so on, because distributed computing environment is spread and various network-based applications are developed. However, as PZP traffic occupies much volume among Internet backbone traffics, transmission bandwidth and quality of service(QoS) of other network applications such as web, ftp, and real-time video cannot be guaranteed. In previous research, the port-based technique which checks well-known port number and the Deep Packet Inspection(DPI) technique which checks the payload of packets were suggested for solving the problem of the P2P traffics, however there were difficulties to apply those methods to detection of P2P traffics because P2P applications are not used well-known port number and payload of packets may be encrypted. A proposed algorithm for identifying P2P heavy traffics based on flow transport parameters and behavioral characteristics can solve the problem of the port-based technique and the DPI technique. The focus of this paper is to identify P2P heavy traffic flows rather than all P2P traffics. P2P traffics are consist of two steps i)searching the opposite peer which have some contents ii) downloading the contents from one or more peers. We define P2P flow patterns on these P2P applications' features and then implement the system to classify P2P heavy traffics.

Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT

  • Masafumi Takafuji;Kakuya Kitagawa;Masaki Ishida;Yoshitaka Goto;Satoshi Nakamura;Naoki Nagasawa;Hajime Sakuma
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.58-67
    • /
    • 2020
  • Objective: Third-generation dual-source computed tomography (3rd-DSCT) allows dynamic myocardial CT perfusion imaging (dynamic CTP) with a 10.5-cm z-axis coverage. Although the increased radiation exposure associated with the 50% wider scan range compared to second-generation DSCT (2nd-DSCT) may be suppressed by using a tube voltage of 70 kV, it remains unclear whether image quality and the ability to quantify myocardial blood flow (MBF) can be maintained under these conditions. This study aimed to compare the image quality, estimated MBF, and radiation dose of dynamic CTP between 2ndDSCT and 3rd-DSCT and to evaluate whether a 10.5-cm coverage is suitable for dynamic CTP. Materials and Methods: We retrospectively analyzed 107 patients who underwent dynamic CTP using 2nd-DSCT at 80 kV (n = 54) or 3rd-DSCT at 70 kV (n = 53). Image quality, estimated MBF, radiation dose, and coverage of left ventricular (LV) myocardium were compared. Results: No significant differences were observed between 3rd-DSCT and 2nd-DSCT in contrast-to-noise ratio (37.4 ± 11.4 vs. 35.5 ± 11.2, p = 0.396). Effective radiation dose was lower with 3rd-DSCT (3.97 ± 0.92 mSv with a conversion factor of 0.017 mSv/mGy∙cm) compared to 2nd-DSCT (5.49 ± 1.36 mSv, p < 0.001). Incomplete coverage was more frequent with 2nd-DSCT than with 3rd-DSCT (1.9% [1/53] vs. 56% [30/54], p < 0.001). In propensity score-matched cohorts, MBF was comparable between 3rd-DSCT and 2nd-DSCT in non-ischemic (146.2 ± 26.5 vs. 157.5 ± 34.9 mL/min/100 g, p = 0.137) as well as ischemic myocardium (92.7 ± 21.1 vs. 90.9 ± 29.7 mL/min/100 g, p = 0.876). Conclusion: The radiation increase inherent to the widened z-axis coverage in 3rd-DSCT can be balanced by using a tube voltage of 70 kV without compromising image quality or MBF quantification. In dynamic CTP, a z-axis coverage of 10.5 cm is sufficient to achieve complete coverage of the LV myocardium in most patients.