• 제목/요약/키워드: Source Generator

검색결과 560건 처리시간 0.029초

Two-dimensional Numerical Simulation of a Pulsed Heat Source High Temperature Inert Gas Plasma MHD Electrical Power Generator

  • Matsumoto, Masaharu;Murakami, Tomoyuki;Okuno, Yoshihiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.589-596
    • /
    • 2008
  • Performance of a pulsed heat source high temperature inert gas plasma MHD electrical power generator, which can be one of the candidates of space-based laser-to-electrical power converter, is examined by a time dependent two dimensional numerical simulation. In the present MHD generator, the inert gas is assumed to be ideally heated to about $10^4K$ pulsed-likely within short time(${\sim}1{\mu}s$) in a stagnant energy input volume, and the energy of high temperature inert gas is converted to the electricity with the medium of pure inert gas plasma without seeding. The numerical simulation results show that an enthalpy extraction ratio(=electrical output energy/pulsed heat energy) of several tens of % can be achieved, which is the same level as the conventional seeded non-equilibrium plasma MHD generator. Although there still exist many phenomena to be clarified and many problems to be overcome in order to realize the system, the pulsed heat source high temperature inert gas MHD generator is surely worth examining in more detail.

  • PDF

Experimental Results of New Ion Source for Performance Test

  • 김태성;정승호;장두희;이광원;인상열
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

Fingerprint Image for the Randomness Algorithm

  • Park, Jong-Min
    • Journal of information and communication convergence engineering
    • /
    • 제8권5호
    • /
    • pp.539-543
    • /
    • 2010
  • We present a random bit generator that uses fingerprint image for the source of random, and random bit generator using fingerprint image for the randomness has not been presented as yet. Fingerprint image is affected by the operational environments including sensing act, nonuniform contact and inconsistent contact, and these operational environments make FPI to be used for the source of random possible. Our generator produces, on the average, 9,334 bits a fingerprint image in 0.03 second. We have used the NIST SDB14 test suite consisting of sixteen statistical tests for testing the randomness of the bit sequence generated by our generator, and as the result, the bit sequence passes all sixteen statistical tests.

A 캐패시터 자력식 삼상동기발전기에 관한 연구 (Study on the Capacitor-self-excited Three-phase Synchronous Generator)

  • 정연택;김영동
    • 대한전기학회논문지
    • /
    • 제33권11호
    • /
    • pp.425-432
    • /
    • 1984
  • This paper is to propse a new self-excitation method of synchronous generator. Instead of conventional exciter of synchronous generator, the additional winding which is arranged in addition to the armature winding, is used in this generator. The output terminal of the additional winding is connected to a capacitor and to a full wave rectifier in series. In this configuration, one source double excitation which is composed of capacitor-self-excitation by lead urrent and direct current excitation by rectifier, is induced. The result is that` The excetation efficency is improved greatly and output waveform is improved also. In three-phase synchronous generator using the new method of the one source double excitation, voltage element (shunt characteristics) and current element (series characteristics)are compounded in scalar by adapting star-point-open-rectifier system. The result is as following` The effect of load power factor angle on voltage regulation is reduced greatly, compound characteristics is become manifold by controlling capacity of capacitor, and transient response is improved.

  • PDF

고전압 용량성 결합 플라즈마 시스템의 개선된 전압 파형 출력을 위한 펄스 전류 발생장치 회로 (Current Source Type Pulse Generator with Improved Output Voltage Waveform for High Voltage Capacitively Coupled Plasma System)

  • 채범석;민주화;서용석;김현배
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.153-160
    • /
    • 2019
  • This study proposes a current source-type pulse generator to improve output voltage and current waveforms under a capacitively coupled plasma (CCP) system. The proposed circuit comprises two parallel-connected current source-type converters. These converters can satisfy the required output waveforms of plasma processing. The parallel-connected converters operate without reverse current fault by applying a time-delay control technique. Conventional voltage source converters based on pulse power supply exhibit drawbacks in short-circuit current, and problems occur when they are applied to a CCP system. The proposed pulse power supply based on a current source converter fundamentally solves the short-circuit current problem. Therefore, this topology can improve the voltage and current accuracy of a CCP system.

시험용 이상전원(異狀電源) 발생장치의 개발에 관한 연구 (A Study on the Development of Abnormal Power Source Generator to Evaluate Electronic Appliances)

  • 박찬원;노재관
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.83-90
    • /
    • 2004
  • Generally, electronic appliances are used on the basis of normal power source supply. The power source inevitably includes the abnormal condition, such as, sudden voltage sagging, power interrupt, and induced noises. As the electronic appliances which include micro-controller-based circuits are being increased recently, the controller circuit sometimes malfunctions by the abnormal condition of the power source. This situation causes serious problems such as hitch of electric appliance, fire and medical instrument glitch, which produces serious situations. In this paper, development of power interrupt tester which is highly suitable for an endurance test device under abnormal power source to microprocessor-based circuits is proposed 89C2051 microcontroller is performed to make power interrupt signal, and software controls peripheral hardwares and built-in functions. Experimental results of this study will offer a good application to electronic appliance maker as a test device of hardware and software debugging use.

  • PDF

음원 위치 검출기의 구현 (Implementation of Sound Source Location Detector)

  • 이종혁;김진천
    • 한국정보통신학회논문지
    • /
    • 제4권5호
    • /
    • pp.1017-1025
    • /
    • 2000
  • 인간의 청각시스템은 두 가지 요소 즉, ITD(Interaural Time Difference)와 IID(Interaural Intensity Difference)를 처리하여 음원의 위치와 추적을 하고 있다. 본 연구에서는 음원의 위치 검출을 위하여 ITD와 IID 뿐만 아니라 이전의 위치 정보를 이용하여 정확한 음원의 방향을 결정할 수 있는 TEPILD(Time Energy Previous Integration Location Detector) 모델을 제안하였다. TEPILD 모델에서 time function generator는 ITD, energy function generator는 IID를 처리할 수 있도록 하였다. 음원은 정현파(500Hz,1kHz, 2kHz, 3kHz), White noise, Pink noise, News, Music으로 하고 음원의 방향은 right, front right, front, front left, left로 하였다. 실험 결과 전체 평균 정확도가99.2로 좋은 결과를 얻을 수 있었으며, TEPILD가 음원 위치 검출기에 이용될 수 있음을 확인하였다.

  • PDF

선박전기설비 시험용 조합형 써 - 지발생장치의 제작과 특성 (Fabrication and Characteristics of a Combination Surge Generator for Testing Shipboard Electrical Systems)

  • 길경석;김윤식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.387-392
    • /
    • 1997
  • This paper describes a combination surge generator for carrying out performance tests on the surge protection circuits of shipboard electrical systems. Pspice simulations were performed to decide the values of the parts required and to analyze the characteristics of the generator circuitry. The surge generator fabricated can produce four of the most common surge test waveforms : the O.5i/S/100kHz Ringwave, the 1.2/50$\mu$S voltage, the 8/20$\mu$S current, and the lO/lOOOi/S voltage wave¬forms specified in ANSI Std. C62. Source impedances of the surge generator are 12$\Omega$ in the O.5$\mu$S/100kHz mode, O.5$\Omega$ in the 1.2/50$\mu$S and 8/20$\mu$S mode, and 40$\Omega$in the l0/1000$\mu$S mode, and are determined by the ratio of the maxi¬mum open - circuit voltage to the maximum short - circuit current. Experimental results show that the surge generator provides most of the outputs required for the testing of the surge protection circuits on shipboard electrical systems.

  • PDF

태양에너지 해수담수화시스템에의 적용을 위한 판형 해수담수기의 열성능에 관한 실험적 연구 (Experimental Study on Thermal Performance of Palte-type Fresh Water Generator for applying Solar Energy Desalination System)

  • 김정배;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.35-41
    • /
    • 2007
  • To demonstrate the desalination system, the demo-plant was scheduled to be installed. The system was planned to use solar thermal collector as heat source and PV as electricity source. For the design of the desalination demonstration system, firstly the solar thermal system would be well designed from the result between the supplied heat into the fresh water generator and the fresh water yield. The generator for demonstration system was chosen as the fresh water generator of the single stage and effect with plate-type heat exchanger using low pressure evaporation method. The test facility for the tests to reveal the relationship between the fresh water yield and the supplied heat flow rate was designed and manufactured. The maximum fresh water yield of two fresh water generators applied in this study was designed as 1.5 Ton/day. The parameters relating with the performance of fresh water generator are known as sea water inlet temperature, hot water inlet temperature, and hot water flow rate. Through the experiments, this study firstly showed detail operation characteristics of the generator and designed the solar thermal system for the demonstration system.

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.