• 제목/요약/키워드: Soundproof Wall

검색결과 34건 처리시간 0.025초

철도교통소음의 특성에 관한연구 (A Study on the Characteristics of Railroad Traffic Noise)

  • 최형일;박상일;염동익
    • 한국환경과학회지
    • /
    • 제16권7호
    • /
    • pp.771-778
    • /
    • 2007
  • This study has been conducted to achieve the following objectives: First, in order to understand the horizontal propagation and attenuation characteristics for the railroad traffic noise, we selected areas within 100 meters away from the railroad and then selected Saemaul-ho and Mugoongwha-ho as the subjects for our experiment. In this way, we analyzed the horizontal propagation and attenuation characteristics for the traffic noise occurring in diversified areas. Second, in order to understand the vertical propagation and attenuation characteristics for the railroad traffic noise, we measured and analyzed the distributional characteristics of vertical sound pressure levels on each floor of multi-storied apartment buildings according to changes of traffic load and types, and the existence or nonexistence of soundproof walls. For the case of the railroad traffic noise, we also selected Samaul-ho and Mugoongwha-ho as the subjects for our experiment, and we measured and analyzed the different noise levels on each floor of multi-storied apartment buildings from the soundproof wall. The results of Horizontal propagation and attenuation characteristics for the railroad traffic noise are as follows: In cases of the flat land, cutting land, and bridge area, as distance increases, the sound pressure level steadily decreases. The sound pressure level for the bridge area is higher than that of the flat land with a measurement of $5.5{\sim}10.2\;dB(A)$. Vertical propagation and attenuation characteristics for the railroad traffic noise are as follows: The amount of sound pressure level decrease is $14.2{\sim}14.8\;dB(A)$ for Samaul-ho and $13.5{\sim}14.3\;dB(A)$ for Mugoongwha-ho when measuring the vertical sound pressure levels at heights lower than 4.5 m, which indicates a fairly large decrease. At 6 m, the amount of decrease is 8.6 dB(A) for Samaul-ho and 8.2 dB(A) for Mugoongwha-ho, which indicates a small decrease.

공동주택의 건식 가변벽체 접합부 차음성능 향상을 위한 구조음장 특성 해석기법에 관한 연구 (Study on Structural-Acoustic Characteristics for Improving Soundproof Qualities to Changeable Wall in Apartment Buildings)

  • 김화일
    • 한국환경과학회지
    • /
    • 제18권11호
    • /
    • pp.1291-1297
    • /
    • 2009
  • The purpose of this study was to establish structural bone noise analysing method for apartments building floor with Structural-Acoustic coupling analysis. Nowadays, noise through floor is recognized as important problem with the consequence that noise isolation technique is studied in the various fields of industry. From among noise factors, resonance sound is main reason for floor's solid noise. therefore, In this study, evaluation method for composite material slab is established and that a case study is suggested with it.

철도연변 방음시설의 소음측정 사례보고 (The Report on the Insertion Loss Measurement by Types of Soundproof Wall for Railway Noise)

  • 심상덕;장강석;김영찬;김두훈;조준호;정우성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1350-1354
    • /
    • 2000
  • 철도 소음에 의한 환경문제가 증가하고 있으나 방음대책으로는 아직까지 방음벽을 철도 연변에 설치하는 것인데 이러한 방음벽은 주위 경관과의 부조화와 열차승객의 시아방해 등으로 높이에 제한을 받는다. 높이를 높이지 않고도 저감효과를 얻을 수 있는 방음벽과 상단형상의 개발이 중요한 연구과제로 대두되고 있다. 본 논문에서는 철도연변에 설치되는 방음벽의 종류별로 삽입손실을 ISO 10847에 근거하여 측정하였으며 그 결과를 상호 비교 분석 평가하였다.

  • PDF

도심지 공사에서의 소음방지 효과에 관한 연구 - 실시공 사례를 위주로 - (A Analysis of the Noise Reduction Measures Efficiency in the Downtown Construction the Remodeling)

  • 조현우;박정훈;강경인
    • 한국건축시공학회지
    • /
    • 제3권4호
    • /
    • pp.123-128
    • /
    • 2003
  • The purpose of this study is to analyze the efficiency of the noise reduction measure in the downtown construction. For decades, the life level rise in Korea makes the environmental issues developed the important issues. Specially the noise problems have become the hot issue in the building construction. This study covers the efficiency of the measures, which is used in the construction field to reduce the noise. The case was obtained by Korean E&C company in 2003. It is used as important sources. The results of this study are as follows; the reduction efficiency is higher than that of the old measure. But more efforts are needed to comfort nearby residents.

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

통풍형 방음벽 개발 및 적용에 관한 연구 (A Study on the development and application of air-passing soundproofing wall)

  • 윤제원;김영찬;김금모;장강석;구본성;엄주용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.658-663
    • /
    • 2011
  • The purpose of this study is to develop an air-passing soundproofing panel with more improved structure to reduce the $CO_2$ emission and installation cost. To reduce the emission of $CO_2$ ; it is suggested to choose low $CO_2$ emission material relative to the aluminum and to reduce the materials by developing a specially designed air-passing soundproofing panel structure. First of all, we performed the flow analysis to predict the wind pressure according to the open angle of the air-passing soundproofing panel and the noise level analysis at the receiver point. To verify the simulation, a prototype of the soundproofing panel was made. The flow test in the wind tunnel and load test were performed. The economic evaluation for the installation of the air-passing soundproofing panel was performed and specifications of the installation was prepared. As the results of this research, it was verified that the wind load was reduced about 40% to that of the conventional one at 25m/s wind speed in the wind tunnel test. By applying the 4m span soundproofing wall with air-passing soundproofing panel and under the cost of 250 thousand $won/m^2$ instead of the conventional 2m span panel, the installation cost will always be lowered than the conventional one in the combination of (60:40~50:50) conventional to air-passing soundproofing panel from the economic evaluation. The 20% reduction of $CO_2$ was found by changing the 50% of aluminum soundproof panel to air-passing soundproofing panel.

  • PDF

The Design Criteria for the Model Development of the New-hanok Type Public buildings - Focused on Expert Opinion Surveys -

  • Park, Joon-Young;Bae, Kang-Won;Kim, So Young;Jung, Kyung-Yoon
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: According to the characteristic of hanok public building, Planning criterion of structure, technology, efficiency, design is needed which can includes various type of new-hanok type public buildings. In this paper, we collect expert opinions to be used as a basis for developing models of New-hanok type Public Buildings. Method: This study was conducted in Research Study and expert surveys. The Part of reviewing Study looked at conception of new-hanok type public buildings model development and overview planning criterion set briefly. Expert surveys were targeted to professors and architects who are related in new-hanok type public buildings model development research. Result: In this study, we suggest improvement direction about planning criterion of new-hanok type public buildings model development based on opinions collected by expert surveys. In conclusion, first, In concept and legal status, it is necessary to adjust clearly than the term and legal status of new-hanok type. Second, various applicability is needed by using new materials and new construction method at the part of planning elements. Third, 'composed structure-convergence type' and 'composed structure-juxtaposed type' should be clearly classified or combined at the part of Setting of type. Forth, improvement on heat insulation, soundproof, waterproof efficiency is demanded to roof, wall, window systems. Fifth, arranging revitalization plan is important.

자기공명영상(MRI) 검사 시 방사선사의 소음노출 (Noise Exposure of Radiographer Caused by Magnetic Resonance Imaging(MRI))

  • 길종원
    • 한국콘텐츠학회논문지
    • /
    • 제16권11호
    • /
    • pp.699-706
    • /
    • 2016
  • 본 연구는 MRI 검사로 인하여 방사선사가 노출되는 소음의 양을 평가하여 소음저감 시설의 필요성과 제도 마련을 제안하고자 하였다. 소음측정은 대전광역시 S 종합병원의 1.5 Tesla MRI 장비(7개 검사)와 3.0 Tesla MRI 장비(16개 검사)를 대상으로 하였고, 소음측정기는 SC-804를 사용하였다. 소음측정 거리는 MRI 검사실 방음문에서 검사자의 업무 위치까지 100cm 이며, 측정 높이는 업무 시 검사자의 귀 높이 100cm 이다. 검사별 소음측정은 각 검사의 시퀀스(Sequence)마다 발생되는 소음 수치를 관측하여 20초마다 기록하였고 검사별 3회씩 측정하여 평균값을 제시하였다. 연구결과 방사선사가 노출되는 소음의 최댓값은 73.3 dB(A)로 3.0 Tesla 장비에서 시행한 MRCP 검사, 검사별 평균소음의 최댓값은 66.9(3.1) dB(A)로 역시 3.0 Tesla 장비에서 시행한 Myelogram 검사이다. 장비별 평균소음은 3.0 Tesla 장비가 61.9(4.1) dB(A), 1.5 Tesla 장비가 52.0(3.1) dB(A)로 3.0 Tesla MRI 장비가 약 10 dB(A) 정도 높았다(p<0.001). 방사선사가 노출되는 소음의 양은 청력에 영향을 미치는 수준은 아니지만 비청력적영향이 발생할 수 있는 수준이다. 소음을 저감하기 위해 MRI 조정실 후면에 커튼을 설치하여 반사음을 제거할 수 있지만, 제도 마련이 선행되어야 할 것이다.

도로소음원에 대한 방음패널 형상별 반사소음 저감효과 (A Reduction Effect in Noise Reflection by Different Shapes of Soundproofing-panel)

  • 김일호;박태호;장서일;이혜인
    • 대한환경공학회지
    • /
    • 제37권2호
    • /
    • pp.120-125
    • /
    • 2015
  • 도시화의 가속화와 더불어 도심의 교통량의 증가로 도로소음피해를 최소화하기 위하여 방음벽의 설치 수요가 증가하고 있다. 설치되고 있는 여러 형태의 방음벽 중, 반사형 방음패널의 경우 불투명 방음패널과 달리 시야를 가리지 않으므로 방음시설을 요구하는 거주자들에게 인기를 얻고 있다. 하지만 반사형 방음패널의 경우, 반사음에 의한 2차 피해를 유발시켜 피해를 줄일 수 있는 방음벽 개발의 필요성이 대두되고 있다. 이에 본 연구에서는 반사형 방음패널의 전면형상 및 기하학적 형태를 변화시켜 반사음의 전달을 최소화 시킬 수 있는 형상을 연구하였다. 일반형 반사형 방음패널과 형상별 방음패널의 반사소음 저감 효과를 비교 한 결과, 곡선형 방음패널이 1.5 dB의 소음저감 효과가 있었다. 또한, 반사음의 증가 또는 감소는 형상별 설계인자에 따라 변화하는 것을 알 수 있었다. 이러한 결과는 방음벽 전면 현상에 따른 반사소음의 저감 기술의 가능성을 보여주는 결과라고 판단된다.

국도의 경관변화 평가-교외지역 국도를 중심으로- (Landscape Changes Assessment of the National Road-Focused on the National Road in Suburb Areas-)

  • 홍영록;권상준;조태동
    • 한국환경생태학회지
    • /
    • 제18권1호
    • /
    • pp.92-102
    • /
    • 2004
  • 본 연구는 국도의 경관구성요소인 산, 하늘, 도로포장면, 가로수, 논밭, 간판ㆍ전신주, 건물, 구조체, 비탈면, 방호ㆍ방음벽, 중앙분리대의 시각량 분석을 통하여 시대별 경관변화를 파악한 결과, 1.국도의 경관구성요소 중 각 시대별로 가장 높은 시각량을 나타낸 것은 도로포장면으로서 국도경관을 분석 평가함에 있어서 도로의 선형은 시각적으로 중요한 구성요소의 하나로 다루어져야 함을 알 수 있었다. 2.국도의 시대별 경관변화는 중앙분리대(F=33.296)와 가로수(F=32.881)에 의한 차이가 가장 두드러진 것으로 나타났으며, 다음 순으로는 하늘(F=24.735)과 산(F=23.477)이 유사한 정도의 차이값을 나타내고 있다. 그러나 건물과 구조체는 통계적으로 차이가 없음이 판명되었다. 3.국도건설은 점차적으로 자연적 요소의 감소와 인공적 요소에 의한 경관이 주를 이루게 됨을 알 수 있었다. 이는 아직까지 국도건설이 경관적ㆍ생태적 건강성을 인지하고 있음에도 불구하고 접근성과 이동성의 기능중심의 논리에서 벗어나지 못하고 있는 현실적 문제를 보여주는 결과이다.