• Title/Summary/Keyword: Sound transmission loss

Search Result 314, Processing Time 0.025 seconds

A Study on the Sound Proof Efficiency of Windows for Road Traffic Noise (도로변 건물의 창문과 방음효과에 대한 평가)

  • 박성배;신재영;정종흡;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.56-62
    • /
    • 1995
  • Recently, the traffic noise around residences and schools has become a serious social problem with the increase of the amount of transportation. This study was performed to investigate the sound proof efficiency of windows for traffic noise. The results were as follows 1) The traffic noise in 19 sites among 22 sampling sites was higher value than 65 dB(A) being roadside environment standard level in the daytime when all windows were opened, while the noise in 22 sampling sites was transmitted below standard level when all windows were closed. 2) The transmission loss of sound level at single window and double windows were 10~25 dB(A) and 11~29 dB(A) respectively. 3) The transmission loss of sound level at sampled school with sound proof pannel was 7~8 dB (A), which was lower 2~7 dB(A) than the theoretical value of the influence assessment . 4) The construction cost of double windows was lower 28% even if include the cost of setting up air conditioner for the summer season and the power consuming cost for its operation than that of sound proof pannel for traffic noise. 5) The effect of transmission loss of windows was more influenced by airtight than materials of windows.

  • PDF

Measurements of mid-frequency transmission loss in shallow waters off the East Sea: Comparison with Rayleigh reflection model and high-frequency bottom loss model (동해 천해환경에서 측정된 중주파수 전달손실 측정: Rayleigh 및 HFBL 모델과의 비교)

  • Lee, Dae Hyeok;Oh, Raegeun;Choi, Jee Woong;Kim, Seongil;Kwon, Hyuckjong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.297-303
    • /
    • 2021
  • When sound waves propagate over long distances in shallow water, measured transmission loss is greater than predicted one using underwater acoustic model with the Rayleigh reflection model due to inhomogeneity of the bottom. Accordingly, the US Navy predicts sound wave propagation by applying the empirical formula-based High Frequency Bottom Loss (HFBL) model. In this study, the measurement and analysis of transmission loss was conducted using mid-frequency (2.3 kHz, 3 kHz) in the shallow water of the East Sea in summer. BELLHOP eigenray tracing output shows that only sound waves with lower grazing angle than the critical angle propagate long distances for several kilometers or more, and the difference between the predicted transmission loss based on the Rayleigh reflection model and the measured transmission loss tend to increase along the propagation range. By comparing the Rayleigh reflection model and the HFBL model at the high grazing angle region, the bottom province, the input value of the HFBL model, is estimated and BELLHOP transmission loss with HFBL model is compared to measured transmission loss. As a result, it agrees well with the measurements of transmission loss.

A Study on Performance Improvement of Sound Absorbing Noise Barrier (흡음형 방음벽의 성능향상에 관한 연구)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.849-854
    • /
    • 2001
  • A study on performance of the sound absorbing noise barrier is presented. Noise barrier of sound absorbing type is composed of the front panel, sound absorbing material, and back panel. For allowing sound path, front panel is usually perforated. The performance of the noise barrier is governed by the opening ratio of the perforated panel, sound absorption coefficient of the sound absorbing material. In this study, the effects of the opening ratio, diameter of the hole, thickness of the sound absorbing material are investigated. It is found that the thickness of the sound absorbing material must be at least 50 mm to ensure the required minimum NRC value 0.70, and the opening ratio is greater than 0.2. It is shown that the thickness of the back panel is crucial in providing required STL (Sound Transmission Loss) value. The performance of the developed noise barrier is measured, where its sound absorbing coefficient and sound transmission loss satisfy the criteria.

  • PDF

Vibration Transmission of Plate-Beam Structure having discontinuity (평판과 보의 연성구조물의 진동에너지 전달특성 분석에 관한 연구)

  • 이형택;김정태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.391-395
    • /
    • 1997
  • The transmission of sound and vibration through structures is of interest in many noise control problems, including architectural acoustics, sound transmission through air craft, spacecraft and ship, and the transmission of noise through machinery and engine enclosures. Statistical Energy Analysis provides a simple and accurate method of approaching these problems. In this paper, comparing the measured coupling loss factor of plate-beam with measured coupling loss factor of mass on the junction will be inspected.

  • PDF

A Study on the Experimental Sound Transmission Loss of Wall-Body in Song Practice Room (노래연습실 벽체의 투과손실에 관한 실험적 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.221-225
    • /
    • 2007
  • Recently, on account of stress relief and settlement of a healthy drinking culture, many people are visiting a song practice room. In case of such song practice room, since the mechanical voice through a loud accompaniment-music and microphone is on using, there has made a very loud noise, and it influences a lot to the adjacent other space and song practice room booth. Consequently, from the designing stage an efficient measures for soundproof and sound-insulation should be arranged. However, as most of the song practice room wall-bodies that already built up or under construction step were constructed merely with consideration on an interior-wise factor only, it is suffering at the soundproof and sound-insulation. Reflecting such viewpoint, this Study has measured Sound Transmission Loss on the subject for the song practice room wall-body recently built up, and based on the actually measured data, by practice of comparison?analysis on it using various evaluation methods, would intends to present a fundamental material for establishment an efficient sound-insulation measure.

  • PDF

Investigating the Effects of Hearing Loss and Hearing Aid Digital Delay on Sound-Induced Flash Illusion

  • Moradi, Vahid;Kheirkhah, Kiana;Farahani, Saeid;Kavianpour, Iman
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.174-179
    • /
    • 2020
  • Background and Objectives: The integration of auditory-visual speech information improves speech perception; however, if the auditory system input is disrupted due to hearing loss, auditory and visual inputs cannot be fully integrated. Additionally, temporal coincidence of auditory and visual input is a significantly important factor in integrating the input of these two senses. Time delayed acoustic pathway caused by the signal passing through digital signal processing. Therefore, this study aimed to investigate the effects of hearing loss and hearing aid digital delay circuit on sound-induced flash illusion. Subjects and Methods: A total of 13 adults with normal hearing, 13 with mild to moderate hearing loss, and 13 with moderate to severe hearing loss were enrolled in this study. Subsequently, the sound-induced flash illusion test was conducted, and the results were analyzed. Results: The results showed that hearing aid digital delay and hearing loss had no detrimental effect on sound-induced flash illusion. Conclusions: Transmission velocity and neural transduction rate of the auditory inputs decreased in patients with hearing loss. Hence, the integrating auditory and visual sensory cannot be combined completely. Although the transmission rate of the auditory sense input was approximately normal when the hearing aid was prescribed. Thus, it can be concluded that the processing delay in the hearing aid circuit is insufficient to disrupt the integration of auditory and visual information.

Evaluation for the Capability of the Sound Insulation and Experimental Analysis for the Improvement of the Sound Insertion Loss of the Air Conditioner-cabinet Considering the Thickness and Aperture of the Partition (파티션의 두께 및 틈새를 고려한 에어컨 캐비닛의 차음 성능 평가 및 음향 삽입 손실 향상에 대한 실험적 분석)

  • Han, Hyung-Suk;Jung, Woo-Seoung;Mo, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.2
    • /
    • pp.263-271
    • /
    • 2008
  • Compressor radiated noise is one of the dominant noise for the outdoor unit of the air conditioner. Therefore, air conditioner makers are trying to reduce it continuously. Even though noise absorption and isolation technology are one of the important parts for reducing the noise from the compressor, it is usually treated to the substitute technology when the noise from the compressor is very difficult to reduce by the compressor noise control only. In this paper, we focus on the property of the sound insulation for the cabinet and measure it applying the theory of the sound transmission loss and insertion loss of the simple enclosure. The insertion loss is evaluated by the experiments according to the thickness and the aperture of the partition in the cabinet.

Prediction Model of the Sound Transmission Loss of Honeycomb Panels for Railway Vehicles (철도차량용 허니콤재의 차음성능 예측모델)

  • Kim, Seock-Hyun;Paek, In-Su;Lee, Hyun-Woo;Kim, Jeong-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.465-470
    • /
    • 2008
  • Sound transmission characteristics are investigated on the honeycomb panels used for railway vehicles. Equivalent orthotropic plate model and equivalent mass law are applied to predict the sound transmission loss (STL) of the honeycomb panels. The predicted values of the STL are compared with the measured values. The reliability and the limitation of the prediction models are investigated. Coincidence effect and local resonance effect on STL are considered. The result of the study shows that the equivalent orthotropic plate model can be used as a good prediction model, if the local resonance frequency is properly applied. finally, ways to improve the severe STL drop by local resonance are proposed and the effect on the sound insulation performance is analysed.

A Study on the Sound Transmission Characteristics of the Corrugated Panels for railway Vehicles (철도차량용 주름패널의 음투과특성에 관한 연구)

  • 김석현;박정모
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.257-264
    • /
    • 1998
  • Sound transmission characteristics are investigated on the corrugated panels which used for railway vehicles. A special purpose program is developed to calculate the sound transmission loss of orthotropic multi-layered panels. Several kinds of corrugated panels are analysed to estimate the transmission performance and the results are compared with the measured data. Calculated transmission losses show good agreement with the measured values in corrugated panels and aluminum/foam multi-layered panels. The analysis results can be utilized to design the corrugated panels and multi-layered panels which are required to reduce the interior noise in railway vehicles.

  • PDF

Construction of acoustics laboratory on the basis of ISO regulations (ISO 음향시험동 설치사례)

  • Han, Hee-Gap;Kim, Kyong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.379-382
    • /
    • 2005
  • Recently, we founded acoustic research laboratory consist of five reverberation rooms on the basis of ISO regulations. Four kinds of experiment are possible in our laboratory such as sound transmission loss of wall, sound attenuation of suspended ceiling, absorption coefficient, reduction of transmitted impact sound by floor coverings. We are going to provide our customers with officially authorized acoustics data.

  • PDF