• Title/Summary/Keyword: Sound insulation performance

Search Result 244, Processing Time 0.034 seconds

The Experimental Study on the Impact Sound Insulation Floors due to Waste Tire Chip (폐타이어 칩의 바닥충격음 차단성능에 관한 실험적 연구)

  • 양관섭;이세현;김홍열;김승민
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.477-484
    • /
    • 1999
  • This study aims to present proper thickness of resilient mount and pattern of chips for the improvement of impact sound isolation. To achieve this aim, field tests were performed to evaluate the performance of impact sound isolation of pilot samples using waste tire chips against light and heavy-weight impacter, which samples were installed over concrete slabs of an apartment housing. In this study, the experiments were performed by the impact sound level of floors in KS F 2810 "Method for field measurement of floor impact level". As results, a flooring structure using waste tire chips as a resilient mount, with no relation to chip's types, has enhanced performance by 1~2 degree in light impact sound isolation, while it has improvement in heavy impact sound isolation. And fiber-type chips have better performance than granule-type ones when they overlaid concrete slab with 15~20 mm of thickness. For the improvement of impact sound isolation, it is recommended that insulating materials should be applied at joints between floating floors and walls, or floating floors and a doorframes, and also waterproof papers should be used for the effective thickness of resilient mount.ent mount.

  • PDF

Sound Insulation Performance of the Panel Structures in High Speed Train: Transmission Loss of the Corrugated and Extruded Panels (고속철도 차음구조의 차음성능: 주름 및 압출재의 투과손실)

  • Kim, Seock-Hyun;Paek, In-Su;Kim, Jeong-Tae
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.82-89
    • /
    • 2007
  • Sound transmission characteristics are investigated on the corrugated steel and aluminium extruded panels used for railway vehicles. Sewell-Sharp-Cremer(SSC) model, equivalent orthotropic plate model and equivalent mass law are applied to predict the sound transmission loss. The predicted values of the sound transmission loss are compared with the measured values. The reliability and the limitation of the prediction models are investigated. For the corrugated panels and honeycomb panels, the coincidence and local resonance severely deteriorate the sound insulation performance around the corresponding frequency bands. The result of the study shows that the equivalent orthotropic plate model and the SSC model can be used as good prediction models, if the coincidence frequency or local resonance frequency is correctly applied.

  • PDF

An Experiment Study on Floor-Impact Sound Insulation by Resilient Materials in Apartment Buildings (완충재의 종류에 따른 공동주택 바닥충격음 차단성능에 관한 실험연구)

  • Youn, Se Cheol;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.4
    • /
    • pp.217-225
    • /
    • 2005
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for nine apartment buildings. The floor-impact sound levels were measured for twenty-five On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

Evaluation of Floor-Impact Sound Insulation for Apartment Buildings (공동주택 바닥충격음의 차음성능 평가)

  • 윤세철;오종민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.932-937
    • /
    • 2003
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among accupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for seven apartment buildings. The floor-impact sound levels were measured for seventeen On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

  • PDF

An Experimental Study on the Prediction of Indoor Sound Level Distribution in Apartment for Exterior Noise (외부소음에 대한 공동주택 실내 소음레벨분포에 관한 실험적 연구)

  • Park, Hyeon-Ku;Kim, Jong-Bin;Kang, Dong-Yong;Jang, Hyun-Choong;Song, Hyuk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.259-264
    • /
    • 2001
  • It is necessary to predict the sound pressure level(SPL) in rooms before designing an apartment when exterior noises are produced. In order to predict SPL for an apartment that has some specific exterior noises, the following should be known: the characteristics of outdoor noise, sound insulation performance and sound level differences of each room. The purpose of this study is to find out the possibility of predicting sound pressure level of rooms in an apartment by analysing sound level differences among rooms. Sound sources used in this experiment are construction noise, aircraft noise, railroad noise, road traffic noise and white noise as a reference to compare with the previous four. These noises were recorded and reproduced by speaker. As a result, we found that within the sound reduction pattern, the sound difference level appeared uniform depending on the sound insulation characteristics of the windows installed when facing the noise source. When the windows having the same acoustic performance were installed, the SPL in each room resulted in nearly the same values.

  • PDF

Comparison of Performance of Sound Insulation Panel for Transformer (변압기용 차음판의 성능 비교)

  • Jeong, H.E.;Choi, B.K.;Kim, H.J.;Gu, D.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1302-1305
    • /
    • 2006
  • Recently, demands for the reduction of noise generated by transformers have been increasing. Accordingly the noise of transformer occasion displeasing to residents therefore the transformer needs to decrease of noise. One method of reduction such a noise is to build a free-standing enclosure of concrete and steel plates around the transformer, however, this method has some disadvantages, for example, a lage area is needed for equipment installation. In the paper, the vibration and noise effect which is transferred from reinforce channel to insulation panel generated by transformer have been identified for the several kinds of insulation panel and damping sheet experimentally.

  • PDF

The estimation of Sound insulation performance by the balcony windows in the reverberant room and anechoic room (실험실에서의 발코니창호 차음성능 평가)

  • Kim, Tae-Hee;Shin, Il-Seop;Cho, Chan-Geun;Oh, Jin-Kyun;Kim, Nam-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.956-959
    • /
    • 2007
  • The extension of a road system result from construction of the builling near the noise source as the roads, railroads. Many people who have a living space near the road are damaged by the noise generated the road system. Therefore, the damage will be reduced by the appropriate measure like putting some distance between receiver and source. The windows are weak among the building materials. But mainly we uses the windows as building exterior materials. So the sound insulation of the balcony windows was measured and compared.

  • PDF

A Study on the Sound Insulation Characteristics of Honeycomb Panels for Offshore Plants (해양플랜트용 허니컴 패널의 차음 특성 연구)

  • Jung, Jae-Deok;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.948-955
    • /
    • 2017
  • Currently, porous materials (e.g., mineral wool) are the core materials used in offshore plant panels, but in spite of their superb acoustic performance, these items must be replaced for environmental reasons. A honeycomb structure is widely used throughout the industry because of its high strength-to-weight ratio. However, research in terms of noise and vibration is minimal. An acoustic study should be conducted by taking advantage of honeycomb structures to replace porous materials. In this study, a simulation was performed assuming that a honeycomb panel is a superposition of symmetric mode and antisymmetric mode. Reliability was verified by comparing a simulation results based on a theory with a experimental results, and the possibility of the panel as a core material was evaluated by studying the sound insulation characteristics of a honeycomb. As the panel thickness increased, the coincidence frequency shifted to low frequency. As the angle between horizontal line and oblique wall and cell-size decreases, the sound insulation performance is improved. And as the cell-wall thickness increased, the sound insulation performance improved.

An Experimental Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 실험적 연구)

  • Baek, Eun-Sun
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.95-100
    • /
    • 2007
  • In apartment houses, said to be similar to a typical housing form, every household share the walls and floors. Many problems inevitably accompany such as an arrangement, as noise and vibration are shared among households. When investigating the percentage of apartment resident's dissatisfaction with housing environments, discontent due to noise ranks the highest. Among many different kinds of noises, noise such as floor crashing sounds show the highest indication rate in the residents' comparison of discontent. Therefore, it is the practice of insulating against noises such as floor crashing sounds that improves the apartment house environments. The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames +Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

A Comparative Study on the Sound Insulation Characteristics of Laminated Glass in Accordance with Material and Composition of Interlayer Film (Interlayer film 재료 및 구성에 따른 접합유리 차음성능 비교)

  • Hong, Jiyoung;Ko, Sangwon;Koh, Hyo-In;Jang, Seungho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.501-505
    • /
    • 2013
  • It is well known that monolithic glass has specific coincidence dip allowing transmittance of noise around the critical frequency. Laminated glass, made of a polyvinyle butyral(PVB) interlayer sandwiched by two panes of glass sheet, has long served for the advantage in noise attenuation properties as well as the safety purpose. More research on the improvement of sound insulation performance is needed, considering much of the noise is still transmitted through the glass. As a preliminary study, authors have made several test specimens, varied combinations of glass and interlayer film, to optimize the acoustic performance. Experimental investigation was carried out to study the sound transmission loss of test specimens in the reverberation chamber by using sound intensity method. Several new applications, instead of the existing PVB laminated glass, show better results in sound transmission loss and low temperature have a bad influence on the acoustic performance.

  • PDF