• Title/Summary/Keyword: Sound insulation performance

Search Result 246, Processing Time 0.025 seconds

A Study on Field Evaluation and Sound Insulation Improvement of Door (도어 차음성능 현장 평가 및 개선방안에 관한 연구)

  • Oh, Jin Kyun;Lee, Won Yeul;Yum, Sung Gon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.11
    • /
    • pp.1012-1019
    • /
    • 2013
  • Recently, awareness of noise is increased and high performance sound insulation performance wall is designed. But in spite of installing high performance sound insulation performance wall, sound insulation performance in space is reduced by door. In this study, Sound insulation performance of doors which commonly used in buildings was measured to analyze current situation in the field and effect of method which increase sound insulation performance is analyzed quantitatively. As a result, sound insulation performance of doors which commonly used in buildings is FSTC 17~29 and can be increased about 2~3 dB by install rubber seal or mohair.

Variations of the Sound Insulation Performance of the Windows for the Sound Source Angle in the Field Test (현장실험에서 음원의 입사각도에 따른 창의 차음성능 변화)

  • Kim, Sun-Woo;Kim, Ki-Yong;Lee, Ok-Kyun;Park, Hyeon-Ku;Song, Hyuk
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1180-1186
    • /
    • 1999
  • The aim of this study is to investigate the sound insulation performance of windows according to the sound source in the field test. For this purpose, an experiment was performed by KSF 2235(method for field measurements of sound insulation of windows and doors). Based on this code, the sound insulation performance fo the windows was measured for different incident angles of the sound and the effect of incident angle was obtained and discussed. Finally, it was found that the sound insulation performance of the windows was affected by the incident angle of sound source, and the sound insulation rating scale was different for the same window. The main factor changing insulation rating scale is considered to be the sound transmission through the carck of the folding part between the two pieces of wndows. Therefore, when evaluating the sound insulation performance of the windows for the field test, first of all the place of the sound source should be identified and generalized.

  • PDF

A study on the sound insulation performance of partition wall between units of apartment house (공동주택 세대간 차음성능에 관한 연구)

  • Ju, Mun Ki;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.51-56
    • /
    • 2010
  • The sound insulation performance is one of the important factor that determined the amenity of housing life in residential building. Especially, Apartment house represents a korea habitation. So the importance of privacy and noise problems between habitable rooms are emphasized in these habitation. This study investigates and find a problem of sound insulation performance of partition wall of the apartment house in current state. The measurements were carried out in apartment house with and without a stair hall. And the measurements also carried out in current state and installing a sound absorbing material in receiving room and changing a front door and installing a inner door. In spite of the same partition wall, difference results were showed according to the stair hall. It is appeared that sound insulation performance without stair hall is 6-7dB(Dw) higher than that with stair hall. In case of without stair hall, sound insulation performance is Dw 49 for single number quantity for airbone sound. And In case of changing a front door and installing a inner door sound insulation performance is Dw 57 for single number quantity for airbone sound. The Results of measuring on the changes a front door and installed a inner door indicated that the flanking sound through front door influenced the sound insulation performance.

Investigation of the sound insulation performance of balcony window through field measurement (현장측정을 통한 발코니 창호의 차음성능에 관한 연구)

  • Ju, Mun Ki
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.63-68
    • /
    • 2009
  • As with the disappearance of a living room window due to the trend in apartment housing construction that prefers a larger, expanded living room, the sound insulation performance of the balcony window is becoming an important factor to determine the level of indoor noise at an apartment unit. Considering that the indoor noise inside an apartment unit is mandated by law at or below 45dB(A), the balcony window is increasingly assuming an even more important role. Sound insulation performance of the window was measured by examining differences in data involving varying angles of incidence of the sound source as obtained from the same balcony window. Also, acoustic intensity measuring was performed at and around the window to determine its sound insulation quality. Results of measuring on the sound source's angles of incidence indicated that the performance showed some differences in lower frequency ranges, though with no significance. Intensity measuring results showed that the sound insulation performance was reduced near the connection part of the window and the window frame.

A Study on the Enhancement of the Sound Insulation Performance of Windows through the Laboratory Tests (실험실 실험을 통한 창의 차음성능 개선에 관한 연구)

  • Kim, Sun-Woo;Chung, Jin-Yun;Lee, Ok-Kyun;Jang, Hyun-Choong;Park, Hyeon-Ku;Song, Hyuk
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.307-314
    • /
    • 2001
  • This study aims to provide fundamental data for enhancing the sound insulation performance of windows. For this study, windows composed of various types and thicknesses, were classified into five categories; fixed, single, double, triple and airtight, and then tested. In order to analyze their sound insulation characteristics and performances. test results were rated using methods such as D, STC, Ts and arithmetical mean. It was found that the sound insulation performance of windows is affected due to their type rather than the thickness of the glass. It was also found that when gap between the inner and outer frames was filled with caulking material, the sound transmission loss at high frequency bands was greatly improved. Therefore, the sound insulation performance of windows would be enhanced by minimizing the gap between frames.

  • PDF

A Study on the Sound Insulation performance Survey Estimation in Apartment house (공동주택의 소음성능 실측평가에 관한 연구)

  • 함진식;박명길
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.219-226
    • /
    • 2001
  • This treatise measures and estimate sound insulation performance of apartment house. Sound insulation performance measured to the floor and wall. Measurement object is apartment occupancy ago of 100㎡ scale built to higher story in Taegu city. Floor Slav's light impact sound level interception performance interacted by benevolent person who carrying out availability of finish material important. Floor Slav's heavy impact sound level interception performance amounted estimation by being good more or less then light impact sound level interception performance. Because sound insulation performance of partition between adjoined generation is gad seldom, privacy infringement becomes anticipation. There was discussion about these results, and presented various kinds future research task to prove sound insulation performance of apartment house.

  • PDF

The sound insulation performance of eco-friendly loess brick wall (친환경 황토벽체의 차음성능 평가에 관한 연구)

  • Lee, Tai-Gang;Kim, Yul;Song, Kook-Gon;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.13-18
    • /
    • 2009
  • Korean traditional houses have been developed in harmony with natural environment and comfortable indoor condition by using the natural resources including building layout, space composition and materials. Originally Korea traditional architectures have used wood lintel constructions and loess walls through the many years. Theses loess have many strength such as highly heat capacity, controling of humidity, a deodorant than any other materials. Nowaday it is recommended to use exterior and interior walls in loess wall to meet the eco-friendly materials to improve our residental environmental. Thus this study aims to research the sound insulation performance of traditional loess brick wall varied with thickness, thermal insulation materials and cavity wall. The sound insulation performance of these loess walls are compared with other masonry wall's and sound insulation performance of th walls were tested in anechoic laboratory to measure the sound transmission loss of these walls. The loess brick wall with 75mm thickness of cavity is shown the sound insulation performance with Rw 57 which is nearly same performances of 1B brick wall and cement 8' block wall, The improving effect of insulation materials is shown in the high frequency bandwidth. Especially, there is improving as much as 11 dB using the extruded poly stylene form(75mm) and poly ethylene film(0.7mm).

Sound Insulation Performance of the Side Layered Panels in the Next Generation High Speed Train (차세대 고속철도 차량 측면 적층재의 차음성능)

  • Lee, Joong-Hyeok;Lee, Ho-Jin;Park, In-Seok;Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.457-462
    • /
    • 2011
  • The sidewall of the HEMU-400x consists of two parts. One is the multi-layered structure including aluminium extruded panel and the other is the double glazed window. When the train runs in a tunnel, the equivalent sound insulation performance of the side wall significantly influences the internal noise levels. In aspect of the sound insulation strategy, it is important to make two parts have similar performance. In this study, the intensity sound transmission loss (ITL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance of the two parts in respect of the weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy is investigated to reduce the interior noise.

  • PDF

A Study on the Evaluation of Sound Insulation Performance of Double Skin Facade -Focus on the Multi-story type of Double Skin Facade- (이중외피시스템의 차음성능 평가에 관한 연구 -전면형 이중외피시스템을 중심으로-)

  • 석호태;차민철
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.11-18
    • /
    • 2004
  • The purpose of this study is to evaluate the sound insulation performance and present fundamental data for sound insulation plan about open and close windows of inner facade and outer facade of Double-skin Facade system applied to multi-story type. The Headquarter of Green Building and the Energy Saving Building in the Korea Institute of Energy Research was selected for experiment. Measurement method which are specified in the Korea Standard 2235 were selected for this study. As the result of this study, 1) Sound insulation performance of Multi-layer type of Double-skin Facades is very excellent about outdoor noise. 2) Vertical level is higher, it shows that more decreases sound pressure level.

A Study on Floor Impact Sound Insulation Performance of Cross-Laminated Timber (CLT): Focused on Joint Types, Species and Thicknesses

  • Yeon-Su HA;Hyo-Jin LEE;Sang-Joon LEE;Jin-Ae SHIN;Da-Bin SONG
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.419-430
    • /
    • 2023
  • In this study, the floor impact sound insulation performance of Korean domestic Cross-Laminated Timber (CLT) slabs was evaluated according to their joint types, species and thicknesses in laboratory experiments. The sound insulation performance of the CLT has not been investigated before, thus, this study was conducted to quantify basic data on floor impact sound insulation performance of CLT slabs. 5-ply and 150 mm thick CLT panels made of 2 species, Larix kaempferi and Pinus densiflora, were used for the study. The CLT panels were assembled by 3 types of inter-panel joints to form floor slabs: spline, butt and half-lap. And the 150 mm thick Larix CLT slabs were stacked to the thicknesses of 300 mm and 450 mm. The heavy-weight floor impact sound insulation performance of the 150 mm CLT slabs were evaluated to be 70 dB for the Larix slabs and 71.6 dB for the Pinus slabs, and the light-weight floor impact sound insulation performance, 78.3 dB and 79.6 dB, respectively. No significant difference in the sound insulation performance was found between the slabs of the 2 species or among the 3 types of joints. The reduction of 1 dB in the heavy-weight floor impact sound and 1.6 dB in the light-weight floor impact sound per 30 mm increase in thickness were confirmed through the experiments. This study can be viewed as the basic research for the evaluation of floor impact sound insulation performance of CLT.