• 제목/요약/키워드: Sound insulation performance

검색결과 244건 처리시간 0.033초

폐타이어 칩의 바닥충격음 차단성능에 관한 실험적 연구 (The Experimental Study on the Impact Sound Insulation Floors due to Waste Tire Chip)

  • 양관섭;이세현;김홍열;김승민
    • 소음진동
    • /
    • 제9권3호
    • /
    • pp.477-484
    • /
    • 1999
  • This study aims to present proper thickness of resilient mount and pattern of chips for the improvement of impact sound isolation. To achieve this aim, field tests were performed to evaluate the performance of impact sound isolation of pilot samples using waste tire chips against light and heavy-weight impacter, which samples were installed over concrete slabs of an apartment housing. In this study, the experiments were performed by the impact sound level of floors in KS F 2810 "Method for field measurement of floor impact level". As results, a flooring structure using waste tire chips as a resilient mount, with no relation to chip's types, has enhanced performance by 1~2 degree in light impact sound isolation, while it has improvement in heavy impact sound isolation. And fiber-type chips have better performance than granule-type ones when they overlaid concrete slab with 15~20 mm of thickness. For the improvement of impact sound isolation, it is recommended that insulating materials should be applied at joints between floating floors and walls, or floating floors and a doorframes, and also waterproof papers should be used for the effective thickness of resilient mount.ent mount.

  • PDF

고속철도 차음구조의 차음성능: 주름 및 압출재의 투과손실 (Sound Insulation Performance of the Panel Structures in High Speed Train: Transmission Loss of the Corrugated and Extruded Panels)

  • 김석현;백인수;김정태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.82-89
    • /
    • 2007
  • Sound transmission characteristics are investigated on the corrugated steel and aluminium extruded panels used for railway vehicles. Sewell-Sharp-Cremer(SSC) model, equivalent orthotropic plate model and equivalent mass law are applied to predict the sound transmission loss. The predicted values of the sound transmission loss are compared with the measured values. The reliability and the limitation of the prediction models are investigated. For the corrugated panels and honeycomb panels, the coincidence and local resonance severely deteriorate the sound insulation performance around the corresponding frequency bands. The result of the study shows that the equivalent orthotropic plate model and the SSC model can be used as good prediction models, if the coincidence frequency or local resonance frequency is correctly applied.

  • PDF

완충재의 종류에 따른 공동주택 바닥충격음 차단성능에 관한 실험연구 (An Experiment Study on Floor-Impact Sound Insulation by Resilient Materials in Apartment Buildings)

  • 윤세철;오종민
    • 환경영향평가
    • /
    • 제14권4호
    • /
    • pp.217-225
    • /
    • 2005
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for nine apartment buildings. The floor-impact sound levels were measured for twenty-five On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

공동주택 바닥충격음의 차음성능 평가 (Evaluation of Floor-Impact Sound Insulation for Apartment Buildings)

  • 윤세철;오종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.932-937
    • /
    • 2003
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among accupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for seven apartment buildings. The floor-impact sound levels were measured for seventeen On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

  • PDF

외부소음에 대한 공동주택 실내 소음레벨분포에 관한 실험적 연구 (An Experimental Study on the Prediction of Indoor Sound Level Distribution in Apartment for Exterior Noise)

  • 박현구;김종빈;강동영;장현충;송혁;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.259-264
    • /
    • 2001
  • It is necessary to predict the sound pressure level(SPL) in rooms before designing an apartment when exterior noises are produced. In order to predict SPL for an apartment that has some specific exterior noises, the following should be known: the characteristics of outdoor noise, sound insulation performance and sound level differences of each room. The purpose of this study is to find out the possibility of predicting sound pressure level of rooms in an apartment by analysing sound level differences among rooms. Sound sources used in this experiment are construction noise, aircraft noise, railroad noise, road traffic noise and white noise as a reference to compare with the previous four. These noises were recorded and reproduced by speaker. As a result, we found that within the sound reduction pattern, the sound difference level appeared uniform depending on the sound insulation characteristics of the windows installed when facing the noise source. When the windows having the same acoustic performance were installed, the SPL in each room resulted in nearly the same values.

  • PDF

변압기용 차음판의 성능 비교 (Comparison of Performance of Sound Insulation Panel for Transformer)

  • 정한얼;최병근;김효중;구동식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1302-1305
    • /
    • 2006
  • Recently, demands for the reduction of noise generated by transformers have been increasing. Accordingly the noise of transformer occasion displeasing to residents therefore the transformer needs to decrease of noise. One method of reduction such a noise is to build a free-standing enclosure of concrete and steel plates around the transformer, however, this method has some disadvantages, for example, a lage area is needed for equipment installation. In the paper, the vibration and noise effect which is transferred from reinforce channel to insulation panel generated by transformer have been identified for the several kinds of insulation panel and damping sheet experimentally.

  • PDF

실험실에서의 발코니창호 차음성능 평가 (The estimation of Sound insulation performance by the balcony windows in the reverberant room and anechoic room)

  • 김태희;신일섭;조창근;오진균;김남욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.956-959
    • /
    • 2007
  • The extension of a road system result from construction of the builling near the noise source as the roads, railroads. Many people who have a living space near the road are damaged by the noise generated the road system. Therefore, the damage will be reduced by the appropriate measure like putting some distance between receiver and source. The windows are weak among the building materials. But mainly we uses the windows as building exterior materials. So the sound insulation of the balcony windows was measured and compared.

  • PDF

해양플랜트용 허니컴 패널의 차음 특성 연구 (A Study on the Sound Insulation Characteristics of Honeycomb Panels for Offshore Plants)

  • 정재덕;홍석윤;송지훈;권현웅
    • 해양환경안전학회지
    • /
    • 제23권7호
    • /
    • pp.948-955
    • /
    • 2017
  • 현재 해양플랜트용 패널의 주요한 중심재는 다공성재료(미네랄울) 이지만, 뛰어난 차음성능에도 불구하고 환경적인 이유로 이를 대체할 재료가 요구되고 있다. 허니컴 구조는 무게 대비 강도가 우수하여 산업전반에서 많이 쓰이고 있다. 하지만 소음진동 측면에서의 연구는 미미하다. 다공성재료를 대체하기 위한 연구로서 허니컴의 음향학적 연구가 필요하다. 본 논문에서는 허니컴패널을 대칭모드와 비대칭모드의 중첩으로 가정하여 수치해석을 진행하였다. 이러한 이론을 통한 수치해석과 실험결과를 비교하여 수치해석의 신뢰성을 검증하였다. 그리고 수치해석을 통해 허니컴패널의 차음특성을 연구하고 중심재로서의 가능성을 평가하였다. 패널두께를 키울수록 일치주파수가 저주파수로 이동하였다. 셀사이즈와 셀벽의 사이각이 감소함에 따라 차음성능이 개선되었고, 셀벽두께의 경우 증가할수록 차음성능이 향상되었다.

천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 실험적 연구 (An Experimental Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses)

  • 백은선
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.95-100
    • /
    • 2007
  • In apartment houses, said to be similar to a typical housing form, every household share the walls and floors. Many problems inevitably accompany such as an arrangement, as noise and vibration are shared among households. When investigating the percentage of apartment resident's dissatisfaction with housing environments, discontent due to noise ranks the highest. Among many different kinds of noises, noise such as floor crashing sounds show the highest indication rate in the residents' comparison of discontent. Therefore, it is the practice of insulating against noises such as floor crashing sounds that improves the apartment house environments. The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames +Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

Interlayer film 재료 및 구성에 따른 접합유리 차음성능 비교 (A Comparative Study on the Sound Insulation Characteristics of Laminated Glass in Accordance with Material and Composition of Interlayer Film)

  • 홍지영;고상원;고효인;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2013
  • It is well known that monolithic glass has specific coincidence dip allowing transmittance of noise around the critical frequency. Laminated glass, made of a polyvinyle butyral(PVB) interlayer sandwiched by two panes of glass sheet, has long served for the advantage in noise attenuation properties as well as the safety purpose. More research on the improvement of sound insulation performance is needed, considering much of the noise is still transmitted through the glass. As a preliminary study, authors have made several test specimens, varied combinations of glass and interlayer film, to optimize the acoustic performance. Experimental investigation was carried out to study the sound transmission loss of test specimens in the reverberation chamber by using sound intensity method. Several new applications, instead of the existing PVB laminated glass, show better results in sound transmission loss and low temperature have a bad influence on the acoustic performance.

  • PDF